3D-TOF sensors in the automobile

被引:3
|
作者
Kahlmann, T [1 ]
Oggier, T [1 ]
Lustenberger, F [1 ]
Blanc, N [1 ]
Ingensand, H [1 ]
机构
[1] Swiss Fed Inst Technol, CH-8093 Zurich, Switzerland
来源
Photonics in the Automobile | 2005年 / 5663卷
关键词
range image; time-of-flight; range camera; calibration; 3D-positioning system;
D O I
10.1117/12.607261
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In recent years, pervasive computing has become an important topic in automobile industry. Besides well-known driving assistant systems such as ABS, ASR and ESP several small tools that support driving activities were developed. The most important reason for integrating new technologies is to increase the safety of passengers as well as road users. The Centre Suisse d'Electronique et de Microtechnique SA (CSEM) Zurich presented the CMOS/CCD real-time range-imaging technology, a measurement principle with a wide field of applications in automobiles. The measuring system is based on the time-of-flight measurement principle using actively modulated radiation. Thereby, the radiation is emitted by the camera's illumination system, reflected by objects in the field of view and finally imaged on the CMOS/CCD sensor by the optics. From the acquired radiation, the phase delay and hence the target distance is derived within each individual pixel. From these distance measurements, three-dimensional coordinates can then be calculated. The imaging sensor acquires its environment data in a high-frequency mode and is therefore appropriate for real-time applications. The basis for decisions which contribute to the increased safety is thus available. In this contribution, first the operational principle of the sensor technology is outlined. Further, some implementations of the technology are presented. At the laboratories of the Institute of Geodesy and Photogrammetry (IGP) at ETH Zurich an implementation of the above mentioned measurement principle, the SwissRangerTM, was investigated in detail. Special attention was focused on the characteristics of this sensor and its calibration. Finally, sample applications within the automobile are introduced.
引用
收藏
页码:216 / 224
页数:9
相关论文
共 50 条
  • [41] MSCTA与3D-TOF MRA对颅内动脉瘤的应用价值对比
    陈忠伟
    影像研究与医学应用, 2020, 4 (11) : 21 - 23
  • [42] 面肌痉挛的3.0T 3D-TOF MRA表现分析及病因诊断
    齐明东
    袁飞
    赵军
    医学影像学杂志, 2013, 23 (08) : 1183 - 1185
  • [43] 3D-TOF相机在空间近距离目标探测中的应用研究
    宋玉志
    卢纯青
    王立
    空间控制技术与应用, 2019, 45 (01) : 53 - 59
  • [44] 3D-TOF MRA诊断颅内动脉瘤的临床价值分析附视频
    张宏
    余玉盛
    李慧
    医学影像学杂志, 2016, (08) : 1527 - 1528
  • [45] 3D-TOF MRA序列在颅内静脉窦血栓中的协助诊断价值
    安攀
    赵沙沙
    梁寿衡
    崔光彬
    雷学斌
    中国CT和MRI杂志, 2023, 21 (11) : 18 - 20
  • [46] Diagnosis of a Dural Arteriovenous Fistula Involving the Superior Sagittal Sinus: The MMA Sign on Routine 3D-TOF MR Angiography
    Naruto, Norihito
    Kido, Aki
    Doai, Mariko
    Yamamoto, Shusuke
    Kashiwazaki, Daina
    Akioka, Naoki
    Kuroda, Satoshi
    Noguchi, Kyo
    ACADEMIC RADIOLOGY, 2024, 31 (09) : 3749 - 3753
  • [47] 优化3D-TOF和并行采集技术在颅内MRA成像中的应用
    付玲涛
    世界最新医学信息文摘, 2018, 18 (83) : 138+140 - 138
  • [48] 3D-TOF MRA在颅内动脉瘤介入栓塞术后随访中的应用
    高玉良
    山东医药, 2009, (18) : 110 - 110
  • [49] 磁共振3D-TOF序列与3D-SPACE序列在脑神经血管成像中的应用
    陈骥梁
    赵颖
    医疗装备, 2016, 29 (21) : 10 - 11
  • [50] Surveillance of Unruptured Intracranial Saccular Aneurysms Using Noncontrast 3D-Black-Blood MRI: Comparison of 3D-TOF and Contrast-Enhanced MRA with 3D-DSA
    Zhu, C.
    Wang, X.
    Eisenmenger, L.
    Tian, B.
    Liu, Q.
    Degnan, A. J.
    Hess, C.
    Saloner, D.
    Lu, J.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2019, 40 (06) : 960 - 966