3D-TOF sensors in the automobile

被引:3
|
作者
Kahlmann, T [1 ]
Oggier, T [1 ]
Lustenberger, F [1 ]
Blanc, N [1 ]
Ingensand, H [1 ]
机构
[1] Swiss Fed Inst Technol, CH-8093 Zurich, Switzerland
来源
Photonics in the Automobile | 2005年 / 5663卷
关键词
range image; time-of-flight; range camera; calibration; 3D-positioning system;
D O I
10.1117/12.607261
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In recent years, pervasive computing has become an important topic in automobile industry. Besides well-known driving assistant systems such as ABS, ASR and ESP several small tools that support driving activities were developed. The most important reason for integrating new technologies is to increase the safety of passengers as well as road users. The Centre Suisse d'Electronique et de Microtechnique SA (CSEM) Zurich presented the CMOS/CCD real-time range-imaging technology, a measurement principle with a wide field of applications in automobiles. The measuring system is based on the time-of-flight measurement principle using actively modulated radiation. Thereby, the radiation is emitted by the camera's illumination system, reflected by objects in the field of view and finally imaged on the CMOS/CCD sensor by the optics. From the acquired radiation, the phase delay and hence the target distance is derived within each individual pixel. From these distance measurements, three-dimensional coordinates can then be calculated. The imaging sensor acquires its environment data in a high-frequency mode and is therefore appropriate for real-time applications. The basis for decisions which contribute to the increased safety is thus available. In this contribution, first the operational principle of the sensor technology is outlined. Further, some implementations of the technology are presented. At the laboratories of the Institute of Geodesy and Photogrammetry (IGP) at ETH Zurich an implementation of the above mentioned measurement principle, the SwissRangerTM, was investigated in detail. Special attention was focused on the characteristics of this sensor and its calibration. Finally, sample applications within the automobile are introduced.
引用
收藏
页码:216 / 224
页数:9
相关论文
共 50 条
  • [31] 3D-TOF磁共振血管成像诊断偏侧面肌痉挛的病因
    胡兴越
    章士正
    薛晶冰
    朱先理
    吕文
    郑伟良
    胡吉波
    邵宇权
    中华神经科杂志, 1999, (04) : 27 - 29+69
  • [32] 单侧颈内动脉闭塞患者Willis环3D-TOF MRA检出的评价
    逄利博
    杨本强
    段阳
    医学影像学杂志, 2017, 27 (11) : 2061 - 2064
  • [33] 3D-TOF法磁共振血流成像对脑血管疾病的诊断价值
    包仕尧
    宋建荣
    临床神经科学, 1997, (03) : 125 - 127+144
  • [34] MR angiography in sickle cell disease: Usefulness of orthogonal 3D-TOF examinations in elimination of artifactual flow gaps
    Snow, RD
    Khader, SM
    Greiner, FG
    Herbert, DE
    Maertens, P
    RIVISTA DI NEURORADIOLOGIA, 1999, 12 : 105 - 108
  • [35] 3D-TOF MRA对颅内血管性病变的诊断价值
    王化敏
    程若勤
    金红花
    时小刚
    吴予晨
    放射学实践, 1998, (02) : 63 - 65
  • [36] 应用磁共振3D-TOF MRA成像观察脑膜瘤供血特征
    郑晔
    李德刚
    杨蔚
    陈兵
    王晓东
    金国宏
    宁夏医学杂志, 2010, 32 (05) : 414 - 415
  • [37] 高场强MRI常规序列及3D-TOF MRA诊断烟雾病的价值
    罗应斌
    唐蕾
    余晖
    重庆医学, 2014, 43 (13) : 1581 - 1583
  • [38] Contrast-enhanced 3D-TOF MRA of peripheral vessels: Intravascular versus extracellular MR contrast media
    Engelbrecht, MR
    Saeed, M
    Wendland, MF
    Canet, E
    Oksendal, AN
    Higgins, CB
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (03): : 616 - 621
  • [39] 3D-TOF MRA成像对脑动脉粥样硬化的诊断价值
    庄向东
    影像研究与医学应用, 2021, 5 (02) : 142 - 143
  • [40] What is the optimal dose of Gd-DTPA in aortic blood during contrast enhanced 3D-TOF MR angiography?
    Chung, TS
    Lee, DH
    Hong, KS
    Chien, D
    Frenzel, T
    Weinmann, HJ
    RADIOLOGY, 1997, 205 : 669 - 669