Statistical reconstruction of x-ray CT images from energy-integrated signals: A simulation study

被引:0
|
作者
Lasio, G
Whiting, B
Williamson, J
机构
[1] Virginia Commonwealth Univ, Richmond, VA 23284 USA
[2] Mallinckrodt Inst Radiol, St Louis, MO USA
关键词
D O I
10.1118/1.1998252
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Statistical reconstruction (SR) algorithms have the potential to significantly reduce X‐ray CT image artifacts due to a more realistic model of the detector signal acquisition process. Most SR algorithms assume that the CT detectors are photon‐counting devices and generate Poisson‐distributed signals. However, actual CT detectors integrate energy and exhibit compound Poisson distributed signal statistics. The goal of this study is to assess the impact on image quality of the resultant mismatch between the detector and signal statistics models assumed by the sinogram and the reconstruction algorithm. Method and Materials: A 2D CT projection simulator software was created to generate synthetic polyenergetic transmission data assuming i) photon‐count signals with simple Poisson distribution and ii) energy‐weighted compound Poisson distributed signals. An Alternating Minimization (AM) algorithm was used to reconstruct images from the data models i) and ii) for a typical abdominal scan protocol and for incident particle fluence levels ranging from 105 to 1.6×106 photons/detector. The phantoms simulated included normal soft tissue, bone, and metal inserts. The images reconstructed from data models i) and ii) were compared by visual inspection and quantitative image‐quality measures. Results: Substantial streaking artifacts appear in images formed from energy‐integrated data when the AM algorithm assumes a particle‐fluence spectrum Φ̄0(E). Once AM's spectrum is replaced by the energy‐fluence spectrum E ⋅Φ̄ (E), AM correctly predicts the data means and eliminates the artifacts. With the energy‐weighted spectrum, the reconstructed image quality from data models i) and ii) does not differ significantly even when SNR is very low. Conclusion: Mismatch between the actual and assumed CT detector signal statistics does not significantly degrade image quality once systematic data means mismatches are corrected. Within the context of statistical image reconstruction, there appears to be no benefit to develop more complex statistical reconstruction algorithms based upon energy‐integrating detector signal statistics models. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2057 / 2057
页数:1
相关论文
共 50 条
  • [1] Simulation Study on an Energy-Modulated X-ray CT
    Ogawa, Koichi
    Kishino, Mayuko
    Yamakawa, Tsutomu
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2559 - 2563
  • [2] Advances in halide perovskite semiconductors for energy-integrated and energy-resolved X-ray detection
    Lai, Yibin
    Yang, Yang
    JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE A, 2024, 25 (10): : 824 - 840
  • [3] Quantifying the Importance of the Statistical Assumption in Statistical X-ray CT Image Reconstruction
    Xu, Jingyan
    Tsui, Benjamin M. W.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2014, 33 (01) : 61 - 73
  • [4] Simulation of X-ray Projection Images for Dimensional CT Metrology
    Welkenhuyzen, F.
    Boeckmans, B.
    Kruth, J. -P.
    Dewulf, W.
    Voet, A.
    OPTICAL MEASUREMENT TECHNIQUES FOR STRUCTURES & SYSTEMS2 (OPTIMESS2012), 2013, : 477 - 487
  • [5] Multispectral X-ray CT - Multivariate Statistical Analysis for Efficient Reconstruction
    Kheirabadi, Mina
    Mustafa, Wail
    Lyksborg, Mark
    Olsen, Ulrik Lund
    Dahl, Anders Bjorholm
    DEVELOPMENTS IN X-RAY TOMOGRAPHY XI, 2017, 10391
  • [6] Simplified statistical image reconstruction algorithm for polyenergetic X-ray CT
    Srivastava, Somesh
    Fessler, Jeffrey A.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1551 - 1555
  • [7] A NEW STATISTICAL IMAGE RECONSTRUCTION ALGORITHM FOR POLYENERGETIC X-RAY CT
    Abella, Monica
    Fessler, Jeffrey A.
    2009 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1 AND 2, 2009, : 165 - 168
  • [8] RECONSTRUCTION OF X-RAY SOURCES FROM PENUMBRAL IMAGES
    GILLMAN, G
    MACLEOD, I
    COMPUTER GRAPHICS AND IMAGE PROCESSING, 1979, 11 (03): : 227 - 241
  • [9] Quantitative Material Reconstruction in CT with Spectroscopic X-ray Pixel Detectors - a Simulation Study
    Firsching, M.
    Niederloehner, D.
    Michel, T.
    Anton, G.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2257 - 2259
  • [10] Statistical modeling challenges in model-based reconstruction for X-ray CT
    Zhang, Ruoqiao
    Chang, Aaron
    Thibault, Jean-Baptiste
    Sauer, Ken
    Bouman, Charles
    COMPUTATIONAL IMAGING XI, 2013, 8657