A Numerical Model of Blood Flow Velocity Measurement Based on Finger Ring

被引:2
|
作者
Fu Yusheng [1 ]
Wang, Qiyu [1 ]
Yi, Jianbo [2 ]
Dan Song [3 ]
Xin Xiang [4 ]
机构
[1] Univ Elect Sci & Technol China, Sch Informat & Commun Engn, Chengdu 611731, Sichuan, Peoples R China
[2] Univ Elect Sci & Technol China, Sch Elect Engn, Chengdu 611731, Sichuan, Peoples R China
[3] Univ Elect Sci & Technol China, Dept Internal Med, Affiliated Hosp, Chengdu 611731, Sichuan, Peoples R China
[4] Air Force Engn Univ, Sch Inst Aeronaut & Astronaut, Xian 710051, Shaanxi, Peoples R China
关键词
TUMOR-CELL DETECTION; HEAT-TRANSFER; CYTOMETER; ENUMERATION; SMARTPHONE; RHEOLOGY; ARTERIES;
D O I
10.1155/2018/3916481
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Aiming to measure the blood flow velocity in a finger, a novel noninvasive method, i.e., a ring with a heat source chip and a temperature sensor, is designed in this paper. The heat source chip is used to heat the finger and generate heat diffusion between the chip and the temperature sensor. And the temperature sensor is designed to measure the temperature difference. Since the blood flow is the main medium of heat diffusion in bodies, part from the heat energy in the tissue will be taken away by the flowing blood. Therefore, the blood flow velocity can be acquired via its relationship with the temperature difference. Compared to the ultrasound Doppler method and the laser Doppler method, the proposed method guarantees a more convenient operation in more flexible work sites. We also analyze the theory between heat transfer and laminar flow. Finally, several simulations are conducted, and the influence of the relevant factors (i.e., the number of blood vessels, the radius, etc.) corresponding to the simulation results is also discussed.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Parameters measurement of coronary blood flow velocity using a fast wavelet transform based algorithm
    Francalancia, C
    Di Virgilio, V
    Conti, E
    Finocchiaro, ML
    Lupi, A
    Cerutti, S
    PROCEEDINGS OF THE 18TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 18, PTS 1-5, 1997, 18 : 875 - 876
  • [32] Full-Field, Video-Based Quantitative Measurement of Retinal Blood Flow Velocity
    Duncan, D. D.
    Ramella-Roman, J.
    Nguyen, Q. D.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [33] THE RESPONSE OF BLOOD-FLOW VELOCITY IN THE OPHTHALMIC ARTERY AND BLOOD-FLOW OF THE FINGER TO WARM AND COLD STIMULI IN GLAUCOMATOUS PATIENTS
    ROJANAPONGPUN, P
    DRANCE, SM
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1993, 231 (07) : 375 - 377
  • [35] HAND AND FINGER BLOOD FLOW
    CATCHPOLE, BN
    JEPSON, RP
    CLINICAL SCIENCE, 1955, 14 (01) : 109 - 120
  • [36] FINGER BLOOD FLOW IN ANTARCTICA
    ELKINGTO.EJ
    JOURNAL OF PHYSIOLOGY-LONDON, 1968, 199 (01): : 1 - &
  • [37] Numerical flow calculation based on velocity integrals on boundary
    Utakoji, Yutaka
    Saitoh, Keishiroh
    Nippon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B, 1994, 60 (578): : 3299 - 3302
  • [38] Measurement of collateral blood flow in a porcine model of aortic coarctation by velocity-encoded cine MRI
    Chernoff, DM
    Derugin, N
    Rajasinghe, HA
    Hanley, FL
    Higgins, CB
    Gooding, CA
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (03): : 557 - 563
  • [39] Oil-water two-phase flow velocity measurement based on ultrasonic Doppler and conductance ring
    Liu W.
    Tan C.
    Dong F.
    Beijing Hangkong Hangtian Daxue Xuebao/Journal of Beijing University of Aeronautics and Astronautics, 2019, 45 (08): : 1536 - 1543
  • [40] The measurement of tumor blood flow in a rat model
    Mathews, JM
    Lee, D
    Binnie, S
    Skeen, NP
    Ewen, J
    Kelly, J
    Barlow, C
    Janssen, H
    FASEB JOURNAL, 2002, 16 (04): : A87 - A87