A Numerical Model of Blood Flow Velocity Measurement Based on Finger Ring

被引:2
|
作者
Fu Yusheng [1 ]
Wang, Qiyu [1 ]
Yi, Jianbo [2 ]
Dan Song [3 ]
Xin Xiang [4 ]
机构
[1] Univ Elect Sci & Technol China, Sch Informat & Commun Engn, Chengdu 611731, Sichuan, Peoples R China
[2] Univ Elect Sci & Technol China, Sch Elect Engn, Chengdu 611731, Sichuan, Peoples R China
[3] Univ Elect Sci & Technol China, Dept Internal Med, Affiliated Hosp, Chengdu 611731, Sichuan, Peoples R China
[4] Air Force Engn Univ, Sch Inst Aeronaut & Astronaut, Xian 710051, Shaanxi, Peoples R China
关键词
TUMOR-CELL DETECTION; HEAT-TRANSFER; CYTOMETER; ENUMERATION; SMARTPHONE; RHEOLOGY; ARTERIES;
D O I
10.1155/2018/3916481
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Aiming to measure the blood flow velocity in a finger, a novel noninvasive method, i.e., a ring with a heat source chip and a temperature sensor, is designed in this paper. The heat source chip is used to heat the finger and generate heat diffusion between the chip and the temperature sensor. And the temperature sensor is designed to measure the temperature difference. Since the blood flow is the main medium of heat diffusion in bodies, part from the heat energy in the tissue will be taken away by the flowing blood. Therefore, the blood flow velocity can be acquired via its relationship with the temperature difference. Compared to the ultrasound Doppler method and the laser Doppler method, the proposed method guarantees a more convenient operation in more flexible work sites. We also analyze the theory between heat transfer and laminar flow. Finally, several simulations are conducted, and the influence of the relevant factors (i.e., the number of blood vessels, the radius, etc.) corresponding to the simulation results is also discussed.
引用
收藏
页数:8
相关论文
共 50 条
  • [11] Finite element numerical analysis of blood flow and temperature distribution in three-dimensional image-based finger model
    He, Ying
    Himeno, Ryutaro
    Liu, Hao
    Yokota, Hideo
    Sun, Zhi Gang
    INTERNATIONAL JOURNAL OF NUMERICAL METHODS FOR HEAT & FLUID FLOW, 2008, 18 (7-8) : 932 - 953
  • [12] Intravascular ultrasound Doppler measurement of blood flow velocity
    Schumacher, M
    Yin, L
    Swaid, S
    Oldenburger, J
    Gilsbach, JM
    Hetzel, A
    JOURNAL OF NEUROIMAGING, 2001, 11 (03) : 248 - 252
  • [13] OCT-BASED MEASUREMENT OF CEREBRAL BLOOD VESSEL STRUCTURE, BLOOD FLOW VELOCITY, AND BLOOD TRANSIT TIME
    Zhou, Junxiong
    Liang, Sida
    Tang, Jianbo
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XXVIII, 2024, 12830
  • [14] Optical flow sensor for continuous invasive measurement of blood flow velocity
    Ruiz-Vargas, Albert
    Morris, Scott A.
    Hartley, Richard H.
    Arkwright, John W.
    JOURNAL OF BIOPHOTONICS, 2019, 12 (10)
  • [15] Groundwater flow velocity and direction measurement sensor based on an equivalent pendulum model and visual measurement
    Tang, Zheng
    Chen, Qili
    Li, Zhuorun
    Wang, Kunsheng
    Qiu, Pengcheng
    Li, Bo
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2025, 36 (02)
  • [16] THE RESPONSE OF BLOOD-FLOW VELOCITY IN FINGER NAILFOLD CAPILLARIES TO CONTRALATERAL COOLING
    BUTTI, P
    FAGRELL, B
    FRONEK, A
    INTAGLIETTA, M
    INTERNATIONAL JOURNAL OF MICROCIRCULATION-CLINICAL AND EXPERIMENTAL, 1982, 1 (01): : 19 - 27
  • [17] Numerical simulation modelling for velocity measurement of electromagnetic flow meter
    Wang, J. Z.
    Gong, C. L.
    Tian, G. Y.
    Lucas, G. P.
    4th International Symposium on Instrumentation Science and Technology (ISIST' 2006), 2006, 48 : 36 - 40
  • [18] MEASUREMENT OF FINGER BLOOD-FLOW BY A NEW VENOUS OCCLUSION HYDROPLETHYSMOGRAPH
    ACEVEDO, A
    SCHNELL, A
    ARCHIVOS DE BIOLOGIA Y MEDICINA EXPERIMENTALES, 1973, 9 (1-3): : 57 - 60
  • [19] MEASUREMENT OF FINGER BLOOD-FLOW BY THE HYDROGEN GAS CLEARANCE METHOD
    NOHARA, S
    NAKAMURA, H
    INTERNATIONAL JOURNAL OF MICROCIRCULATION-CLINICAL AND EXPERIMENTAL, 1986, 5 (2-3): : 240 - 240
  • [20] A Novel Model to Predict Cutaneous Finger Blood Flow via Finger and Rectal Temperatures
    Carrillo, Andres E.
    Cheung, Stephen S.
    Flouris, Andreas D.