A Numerical Model of Blood Flow Velocity Measurement Based on Finger Ring

被引:2
|
作者
Fu Yusheng [1 ]
Wang, Qiyu [1 ]
Yi, Jianbo [2 ]
Dan Song [3 ]
Xin Xiang [4 ]
机构
[1] Univ Elect Sci & Technol China, Sch Informat & Commun Engn, Chengdu 611731, Sichuan, Peoples R China
[2] Univ Elect Sci & Technol China, Sch Elect Engn, Chengdu 611731, Sichuan, Peoples R China
[3] Univ Elect Sci & Technol China, Dept Internal Med, Affiliated Hosp, Chengdu 611731, Sichuan, Peoples R China
[4] Air Force Engn Univ, Sch Inst Aeronaut & Astronaut, Xian 710051, Shaanxi, Peoples R China
关键词
TUMOR-CELL DETECTION; HEAT-TRANSFER; CYTOMETER; ENUMERATION; SMARTPHONE; RHEOLOGY; ARTERIES;
D O I
10.1155/2018/3916481
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Aiming to measure the blood flow velocity in a finger, a novel noninvasive method, i.e., a ring with a heat source chip and a temperature sensor, is designed in this paper. The heat source chip is used to heat the finger and generate heat diffusion between the chip and the temperature sensor. And the temperature sensor is designed to measure the temperature difference. Since the blood flow is the main medium of heat diffusion in bodies, part from the heat energy in the tissue will be taken away by the flowing blood. Therefore, the blood flow velocity can be acquired via its relationship with the temperature difference. Compared to the ultrasound Doppler method and the laser Doppler method, the proposed method guarantees a more convenient operation in more flexible work sites. We also analyze the theory between heat transfer and laminar flow. Finally, several simulations are conducted, and the influence of the relevant factors (i.e., the number of blood vessels, the radius, etc.) corresponding to the simulation results is also discussed.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] ULTRASONIC MTI MEASUREMENT OF VELOCITY PROFILES IN BLOOD-FLOW
    ANGELSEN, BAJ
    KRISTOFFERSEN, K
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1979, 26 (12) : 665 - 671
  • [22] MEASUREMENT OF CORONARY BLOOD-FLOW VELOCITY IN CONSCIOUS RATS
    JONES, LF
    LANDAS, SK
    JOHNSON, AK
    AMERICAN JOURNAL OF PHYSIOLOGY, 1994, 266 (02): : H840 - H845
  • [23] TRANSCUTANEOUS MEASUREMENT OF BLOOD-FLOW VELOCITY IN HUMAN AORTA
    ANGELSEN, BAJ
    BRUBAKK, AO
    CARDIOVASCULAR RESEARCH, 1976, 10 (03) : 368 - 379
  • [24] NEONATAL CEREBRAL BLOOD-FLOW VELOCITY-MEASUREMENT
    PERLMAN, JM
    CLINICS IN PERINATOLOGY, 1985, 12 (01) : 179 - 193
  • [25] ON ULTRASONIC MTI MEASUREMENT OF VELOCITY PROFILES IN BLOOD-FLOW
    ANGELSEN, BAJ
    KRISTOFFERSEN, K
    MODELING IDENTIFICATION AND CONTROL, 1981, 2 (02) : 57 - 70
  • [26] MEASUREMENT OF LINEAR VELOCITY OF BLOOD FLOW IN DOGS BY POLAROGRAPHIC METHOD
    CHERNYAK.IN
    BIOPHYSICS-USSR, 1966, 11 (01): : 215 - &
  • [28] Noninvasive Simultaneous Measurement of Blood Pressure and Blood Flow Velocity for Hemodynamic Analysis
    Kato, Yuki
    Yoshimoto, Shunsuke
    Kuroda, Yoshihiro
    Imura, Masataka
    Yamashita, Shingo
    Ogura, Toshihiko
    Oshiro, Osamu
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 2570 - 2573
  • [29] A Microfluidics-based Pulpal Arteriole Blood Flow Phantom for Validation of Doppler Ultrasound Devices in Pulpal Blood Flow Velocity Measurement
    Kim, Dohyun
    Park, Sung-Ho
    JOURNAL OF ENDODONTICS, 2016, 42 (11) : 1660 - 1666
  • [30] Characteristics of blood flow velocity in the radial artery and finger capillaries using magnetoplethysmogram and photoplethysmogram
    Lee, Sang-Suk
    Choi, Rak-Gun
    Kim, Won-Tae
    Shin, Myung-Woo
    Choi, Jong-Gu
    Hasan, Mahbub
    Jung, Byungjo
    AIP ADVANCES, 2024, 14 (02)