A Numerical Model of Blood Flow Velocity Measurement Based on Finger Ring

被引:2
|
作者
Fu Yusheng [1 ]
Wang, Qiyu [1 ]
Yi, Jianbo [2 ]
Dan Song [3 ]
Xin Xiang [4 ]
机构
[1] Univ Elect Sci & Technol China, Sch Informat & Commun Engn, Chengdu 611731, Sichuan, Peoples R China
[2] Univ Elect Sci & Technol China, Sch Elect Engn, Chengdu 611731, Sichuan, Peoples R China
[3] Univ Elect Sci & Technol China, Dept Internal Med, Affiliated Hosp, Chengdu 611731, Sichuan, Peoples R China
[4] Air Force Engn Univ, Sch Inst Aeronaut & Astronaut, Xian 710051, Shaanxi, Peoples R China
关键词
TUMOR-CELL DETECTION; HEAT-TRANSFER; CYTOMETER; ENUMERATION; SMARTPHONE; RHEOLOGY; ARTERIES;
D O I
10.1155/2018/3916481
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Aiming to measure the blood flow velocity in a finger, a novel noninvasive method, i.e., a ring with a heat source chip and a temperature sensor, is designed in this paper. The heat source chip is used to heat the finger and generate heat diffusion between the chip and the temperature sensor. And the temperature sensor is designed to measure the temperature difference. Since the blood flow is the main medium of heat diffusion in bodies, part from the heat energy in the tissue will be taken away by the flowing blood. Therefore, the blood flow velocity can be acquired via its relationship with the temperature difference. Compared to the ultrasound Doppler method and the laser Doppler method, the proposed method guarantees a more convenient operation in more flexible work sites. We also analyze the theory between heat transfer and laminar flow. Finally, several simulations are conducted, and the influence of the relevant factors (i.e., the number of blood vessels, the radius, etc.) corresponding to the simulation results is also discussed.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] MEASUREMENT OF BLOOD FLOW IN VASODILATED FINGER
    PRICE, WH
    CLINICAL SCIENCE, 1966, 30 (01) : 13 - &
  • [2] Measurement model of ultrasonic flow velocity based on neural network
    Zhongnan Gongye Daxue Xuebao/Journal of Central South University of Technology, 2003, 34 (04):
  • [3] Blood Flow Velocity Measurement: CCF based on I/Q signal
    Wang, Jing
    Liu, Dong C.
    2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
  • [4] Non-Invasive Measurement of Blood Flow Velocity Based on Photoacoustic Calorimetric Measurement
    Xu L.
    Zhang H.
    Li D.
    Chen B.
    Zheng Y.
    Yao L.
    Zhongguo Jiguang/Chinese Journal of Lasers, 2024, 51 (03):
  • [5] Non-Invasive Measurement of Blood Flow Velocity Based on Photoacoustic Calorimetric Measurement
    Xu, Luhan
    Hao, Zhang
    Dong, Li
    Bin, Chen
    Zheng, Yuping
    Yao, Liang
    CHINESE JOURNAL OF LASERS-ZHONGGUO JIGUANG, 2024, 51 (03):
  • [6] Measurement of blood flow and velocity with innovative techniques
    Cevenini, G
    Massai, MR
    Barbini, P
    AEI AUTOMAZIONE ENERGIA INFORMAZIONE, 1996, 83 (02): : 137 - 142
  • [7] TRANSCUTANEOUS MEASUREMENT OF BLOOD VELOCITY PROFILES AND FLOW
    HISTAND, MB
    MILLER, CW
    MCLEOD, FD
    CARDIOVASCULAR RESEARCH, 1973, 7 (05) : 703 - 712
  • [8] Blood flow and blood velocity measurement in vivo by electromagnetic induction
    Wyatt, D.G.
    1600, (22):
  • [9] High-resolution blood flow velocity measurements in the human finger
    Klarhöfer, M
    Csapo, B
    Balassy, C
    Szeles, JC
    Moser, E
    MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (04) : 716 - 719
  • [10] BLOOD FLOW VELOCITY MEASUREMENT BY ULTRASONIC DOPPLER EFFECT . VELOCITY PROFILES AND VELOCITY . FLOW RATE RELATION
    PERONNEA.P
    CHEVRIER, JL
    HUNG, BM
    LEGER, F
    HINGLAIS, J
    EUROPEAN SURGICAL RESEARCH, 1969, 1 (03) : 238 - &