Objective: To test the hypothesis that there is no difference in the accuracy of bracket placement produced by OrthoCAD iQ indirect bonding (IDB) and that of an in-house fabricated IDB system by measuring the quality of intra-arch dental alignment at the end of simulated orthodontic treatment. Materials and Methods: Twenty-eight artificial teeth were arranged to resemble a typical preorthodontic malocclusion. Forty-six sets of models were duplicated from the original malocclusion and randomly divided into two sample groups. Half of the models had their bracket positions selected by OrthoCAD, while the others were completed by a combination of faculty and residents in a university orthodontic department. Indirect bonding trays were fabricated for each sample and the brackets were transferred back to the original malocclusion following typical bonding protocol. The individual teeth were ligated on a.021 x .025-inch stainless steel archwire to simulate their posttreatment positions. The two sample groups were compared using the objective grading system (OGS) originally designed by the American Board of Orthodontics. Results: The mean total OGS score for the OrthoCAD sample group was 39.25 points, while the traditional IDB technique scored 41.00 points. No statistical difference was found between total scores or any of the four components evaluated. Similar ranges of scores were observed, with the OrthoCAD group scoring from 30 to 52 points and the traditional IDB group scoring from 33 to 53 points. Conclusions: The hypothesis is not accepted. OrthoCAD iQ does not currently offer a system that can position orthodontic brackets better or more reliably than traditional indirect bonding techniques. (Angle Orthod. 2011;81:828-835.)
引用
收藏
页码:828 / 835
页数:8
相关论文
共 50 条
  • [41] A COMPUTER-AIDED COMPUTER
    不详
    NEW SCIENTIST, 1984, 104 (1429) : 23 - 23
  • [42] Computer-aided drug discovery: From traditional simulation methods to language models and quantum computing
    Pei, Zongrui
    CELL REPORTS PHYSICAL SCIENCE, 2024, 5 (12):
  • [43] USE OF HISTOGRAMS IN COMPUTER-AIDED COMPARISON OF CHROMATOGRAMS
    GABOR, V
    GABOR, A
    JOURNAL OF CHROMATOGRAPHY, 1985, 318 (02): : 247 - 253
  • [44] Computer-aided pedicle screw placement using frameless stereotaxis
    Glossop, ND
    Hu, RW
    Randle, JA
    SPINE, 1996, 21 (17) : 2026 - 2034
  • [45] Computer-Aided Optimization of Surveillance Cameras Placement on Construction Sites
    Yang, Xincong
    Li, Heng
    Huang, Ting
    Zhai, Ximei
    Wang, Fenglai
    Wang, Chen
    COMPUTER-AIDED CIVIL AND INFRASTRUCTURE ENGINEERING, 2018, 33 (12) : 1110 - 1126
  • [46] COMPARISON OF 3 COMPUTER-AIDED DESIGN PROGRAMS
    DICKHAUT, RH
    ELECTRO-TECHNOLOGY, 1967, 79 (01): : 88 - &
  • [47] COMPUTER-AIDED VOICE COMPARISON FOR FORENSIC PURPOSES
    VANDERGIET, G
    KUNZEL, HJ
    KRIMINALISTIK, 1981, (09): : 341 - 346
  • [48] VARIANCE ANALYSIS AND COMPARISON IN COMPUTER-AIDED DESIGN
    Ullrich, Torsten
    Schiffer, Thomas
    Schinko, Christoph
    Fellner, Dieter W.
    4TH ISPRS INTERNATIONAL WORKSHOP 3D-ARCH 2011: 3D VIRTUAL RECONSTRUCTION AND VISUALIZATION OF COMPLEX ARCHITECTURES, 2011, 38-5 (W16): : 149 - 153
  • [49] Basic concepts in the plane and spatial coordinate geometry - Comparison of traditional and computer-aided mathematics education
    Ostermann, Iris
    JOURNAL FUR MATHEMATIK-DIDAKTIK, 2007, 28 (01): : 86 - 87
  • [50] Analysis of Designer Emotions in Collaborative and Traditional Computer-Aided Design
    Zhou, Jinxuan
    Phadnis, Vrushank
    Olechowski, Alison
    JOURNAL OF MECHANICAL DESIGN, 2021, 143 (02)