A comparison of traditional and computer-aided bracket placement methods

被引:15
|
作者
Israel, Matthew
Kusnoto, Budi [1 ]
Evans, Carla A. [1 ]
BeGole, Ellen [1 ]
机构
[1] Univ Illinois, Dept Orthodont, Chicago, IL 60612 USA
关键词
3D models; Diagnostic; Indirect bonding; Orthodontics; INDIRECT BONDING TECHNIQUES;
D O I
10.2319/072110-425.1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To test the hypothesis that there is no difference in the accuracy of bracket placement produced by OrthoCAD iQ indirect bonding (IDB) and that of an in-house fabricated IDB system by measuring the quality of intra-arch dental alignment at the end of simulated orthodontic treatment. Materials and Methods: Twenty-eight artificial teeth were arranged to resemble a typical preorthodontic malocclusion. Forty-six sets of models were duplicated from the original malocclusion and randomly divided into two sample groups. Half of the models had their bracket positions selected by OrthoCAD, while the others were completed by a combination of faculty and residents in a university orthodontic department. Indirect bonding trays were fabricated for each sample and the brackets were transferred back to the original malocclusion following typical bonding protocol. The individual teeth were ligated on a.021 x .025-inch stainless steel archwire to simulate their posttreatment positions. The two sample groups were compared using the objective grading system (OGS) originally designed by the American Board of Orthodontics. Results: The mean total OGS score for the OrthoCAD sample group was 39.25 points, while the traditional IDB technique scored 41.00 points. No statistical difference was found between total scores or any of the four components evaluated. Similar ranges of scores were observed, with the OrthoCAD group scoring from 30 to 52 points and the traditional IDB group scoring from 33 to 53 points. Conclusions: The hypothesis is not accepted. OrthoCAD iQ does not currently offer a system that can position orthodontic brackets better or more reliably than traditional indirect bonding techniques. (Angle Orthod. 2011;81:828-835.)
引用
收藏
页码:828 / 835
页数:8
相关论文
共 50 条
  • [21] Review and Comparison of Form Error Simulation Methods for Computer-Aided Tolerancing
    Yan, Xingyu
    Ballu, Alex
    JOURNAL OF COMPUTING AND INFORMATION SCIENCE IN ENGINEERING, 2019, 19 (01)
  • [22] Computer-aided manufacturing technologies for guided implant placement
    Neugebauer, Joerg
    Stachulla, Gerhard
    Ritter, Lutz
    Dreiseidler, Timo
    Mischkowski, Robert A.
    Keeve, Erwin
    Zoeller, Joachim E.
    EXPERT REVIEW OF MEDICAL DEVICES, 2010, 7 (01) : 113 - 129
  • [23] Accuracy of different types of computer-aided design/computer-aided manufacturing surgical guides for dental implant placement
    Geng, Wei
    Liu, Changying
    Su, Yucheng
    Li, Jun
    Zhou, Yanmin
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2015, 8 (06): : 8442 - 8449
  • [24] COMPUTER-AIDED CONCRETE-PLACEMENT OPTIMIZATION - CLOSURE
    PHELAN, RS
    RADJY, F
    HAAS, C
    HENDRICKSON, C
    JOURNAL OF CONSTRUCTION ENGINEERING AND MANAGEMENT-ASCE, 1993, 119 (04): : 862 - 866
  • [25] Computer-aided design/computer-aided manufacturing surgical guidance for placement of dental implants: case report.
    Wong, N. Y.
    Huffer-Charchut, H.
    Sarment, D.
    IMPLANT DENTISTRY, 2007, 16 (03) : 326 - 326
  • [26] Computer-aided design and Computer-aided engineering
    Kolbasin, Alexander
    Husu, Oksana
    INTERNATIONAL SCIENCE CONFERENCE SPBWOSCE-2017 BUSINESS TECHNOLOGIES FOR SUSTAINABLE URBAN DEVELOPMENT, 2018, 170
  • [27] COMPUTER-AIDED DESIGN AND COMPUTER-AIDED MANUFACTURING
    WEINBERGSTABER, M
    DU-DIE ZEITSCHRIFT DER KULTUR, 1984, (02): : 89 - 89
  • [28] The Impact of Computer-aided Translation on Traditional Translation Teaching
    Zhang, Wanfang
    Liu, Xiangxin
    2017 2ND AASRI INTERNATIONAL CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (IEA 2017), 2017, : 3 - 6
  • [29] Accuracy of Computer-Aided Dynamic Navigation Compared to Computer-Aided Static Navigation for Dental Implant Placement: An In Vitro Study
    Mediavilla Guzman, Alfonso
    Riad Deglow, Elena
    Zubizarreta-Macho, Alvaro
    Agustin-Panadero, Ruben
    Hernandez Montero, Sofia
    JOURNAL OF CLINICAL MEDICINE, 2019, 8 (12)
  • [30] COMPUTER-AIDED QUALITY SORTING BY ELECTROMAGNETIC METHODS
    KLEIN, K
    RUCKER, D
    MATERIALS EVALUATION, 1985, 43 (10) : 1314 - 1314