A comparison of traditional and computer-aided bracket placement methods

被引:15
|
作者
Israel, Matthew
Kusnoto, Budi [1 ]
Evans, Carla A. [1 ]
BeGole, Ellen [1 ]
机构
[1] Univ Illinois, Dept Orthodont, Chicago, IL 60612 USA
关键词
3D models; Diagnostic; Indirect bonding; Orthodontics; INDIRECT BONDING TECHNIQUES;
D O I
10.2319/072110-425.1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To test the hypothesis that there is no difference in the accuracy of bracket placement produced by OrthoCAD iQ indirect bonding (IDB) and that of an in-house fabricated IDB system by measuring the quality of intra-arch dental alignment at the end of simulated orthodontic treatment. Materials and Methods: Twenty-eight artificial teeth were arranged to resemble a typical preorthodontic malocclusion. Forty-six sets of models were duplicated from the original malocclusion and randomly divided into two sample groups. Half of the models had their bracket positions selected by OrthoCAD, while the others were completed by a combination of faculty and residents in a university orthodontic department. Indirect bonding trays were fabricated for each sample and the brackets were transferred back to the original malocclusion following typical bonding protocol. The individual teeth were ligated on a.021 x .025-inch stainless steel archwire to simulate their posttreatment positions. The two sample groups were compared using the objective grading system (OGS) originally designed by the American Board of Orthodontics. Results: The mean total OGS score for the OrthoCAD sample group was 39.25 points, while the traditional IDB technique scored 41.00 points. No statistical difference was found between total scores or any of the four components evaluated. Similar ranges of scores were observed, with the OrthoCAD group scoring from 30 to 52 points and the traditional IDB group scoring from 33 to 53 points. Conclusions: The hypothesis is not accepted. OrthoCAD iQ does not currently offer a system that can position orthodontic brackets better or more reliably than traditional indirect bonding techniques. (Angle Orthod. 2011;81:828-835.)
引用
收藏
页码:828 / 835
页数:8
相关论文
共 50 条
  • [31] NEW METHODS OF COMPUTER-AIDED ANALYSIS IN PHARMACOGNOSY
    SAUKEL, J
    PLANTA MEDICA, 1988, (06) : 568 - 568
  • [32] New methods in computer-aided dental implantology
    Stopp, S.
    Maier, T.
    Lueth, T. C.
    MKG-CHIRURG, 2008, 1 (01): : 10 - 21
  • [33] COMPUTER-AIDED PROTEIN DESIGN - METHODS AND APPLICATIONS
    SCHOMBURG, D
    ADVANCES IN PROTEIN DESIGN : INTERNATIONAL WORKSHOP 1988, 1989, 12 : 45 - 56
  • [34] On Variance Based Methods in Computer-Aided Phonocardiography
    Gavrovska, Ana M.
    Paskas, Milorad P.
    Reljin, Irini S.
    Reljin, Branimir D.
    2014 12TH SYMPOSIUM ON NEURAL NETWORK APPLICATIONS IN ELECTRICAL ENGINEERING (NEUREL), 2014, : 9 - 12
  • [35] COMPUTER-AIDED METHODS FOR DEVELOPMENT OF TRANSITION SECTIONS
    DHANDE, SG
    RAMULU, PB
    JOURNAL OF MECHANISMS TRANSMISSIONS AND AUTOMATION IN DESIGN-TRANSACTIONS OF THE ASME, 1984, 106 (03): : 401 - 408
  • [36] Computer-aided oral implantology: Methods and applications
    Xiaojun, C.
    Yanping, L.
    Yiqun, W.
    Chengtao, W.
    Journal of Medical Engineering and Technology, 2007, 31 (06): : 459 - 467
  • [37] Computer-Aided Selection of Participatory Design Methods
    Bojko, Michael
    Riedel, Ralph
    Tawalbeh, Mandy
    ADVANCES IN PRODUCTION MANAGEMENT SYSTEMS: TOWARDS SMART PRODUCTION MANAGEMENT SYSTEMS, APMS 2019, PT II, 2019, : 466 - 474
  • [38] COMPUTER-AIDED METHODS IN LIQUID-CHROMATOGRAPHY
    BERRIDGE, JC
    CHEMISTRY IN BRITAIN, 1987, 23 (11) : 1063 - &
  • [39] TRENDS IN COMPUTER-AIDED ONLINE MEASUREMENT METHODS
    GUNDELACH, VG
    COMPUTERS & CHEMICAL ENGINEERING, 1984, 8 (05) : 255 - 266
  • [40] NEW METHODS IN COMPUTER-AIDED DRUG DESIGN
    SHERIDAN, RP
    VENKATARAGHAVAN, R
    ACCOUNTS OF CHEMICAL RESEARCH, 1987, 20 (09) : 322 - 329