Trueness evaluation of digital impression: The impact of the selection of reference and test object

被引:16
|
作者
Yatmaz, Berfin Bahar [1 ]
Raith, Stefan [1 ]
Reich, Sven [1 ]
机构
[1] Rhein Westfal TH Aachen, Dept Prosthodont & Biomat, Subject & Res Area Computerized Dent, Pauwelsstr 30, D-52074 Aachen, Germany
关键词
Trueness; Evaluation; 3D comparison; Digital; Intraoral; Scanner; ACCURACY; SYSTEMS;
D O I
10.1016/j.jdent.2021.103706
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: This study evaluated the importance of defining the reference and the test object during 3D surface comparisons to assess the trueness of an intraoral scanner. Materials and methods: A maxillary complete-arch cast with interdental spaces was digitized with a high resolution scanner to obtain the ground truth dataset [GT]. Fifteen intraoral scanning datasets [IOS] were obtained with an intraoral scanner. The trueness of the [IOS] datasets were evaluated by two different comparison procedures using a 3D analysis software: In the first comparison [REF-GT], the [GT] dataset was set as reference object and the [IOS] dataset was defined as test object. In the second comparison [REF-IOS], the [IOS] dataset were set as reference object and the [GT] dataset was defined as test object. The mean trueness of both comparisons was calculated with absolute mean deviation, (90-10)/2 percentile, and root-mean-squared (RMS) error method. Statistical significance was analyzed using the t-test (alpha=0.05). Results: The mean trueness values of [REF-GT] were 31.4(+/- 6.1) mu m for (90-10)/2 percentile, 77.0(+/- 5.3) mu m for absolute mean deviation, and 203.1(+/- 4.8) mu m for RMS error method. [REF-IOS] revealed 23.9(+/- 4.8) mu m, 28.3 (+/- 6.3) mu m, and 39.6(+/- 9.5) mu m, respectively. The results differed significantly. Conclusion: The datasets obtained from the intraoral scanner captured more adequately interproximal spaces in comparison to the [GT] dataset. Therefore, the [GT] dataset defined as reference object in the analysis software for 3D comparisons revealed misleading results. Clinical significance: The selection of the reference object and of the areas to be compared have to be defined carefully regarding complete arch scanning accuracy analysis.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Development and Validity Evaluation of a National Digital Entrance Examination Test for Higher Education Student Selection
    Talman, K.
    Vierula, J.
    Karihtala, T.
    Laakkonen, E.
    Engblom, J.
    Haavisto, E.
    HIGHER EDUCATION QUARTERLY, 2025, 79 (01)
  • [42] DETERMINATION OF REFERENCE TEMPERATURES FOR COLD TEST IN DIGITAL PLETHYSMOGRAPHY
    PISTORIUS, MA
    BRIANT, C
    PLANCHON, B
    JOURNAL DES MALADIES VASCULAIRES, 1994, 19 (03) : 195 - 198
  • [43] Evaluation of trueness and precision of removable partial denture metal frameworks manufactured with digital technology and different materials
    Ciocca, Leonardo
    Maltauro, Mattia
    Pierantozzi, Elena
    Breschi, Lorenzo
    Montanari, Angela
    Anderlucci, Laura
    Meneghello, Roberto
    JOURNAL OF ADVANCED PROSTHODONTICS, 2023, 15 (02): : 55 - 62
  • [44] Evaluation of compressive strength investigation on job mix test object and core drill test object
    Sitorus, Torang
    Jaya, Indra
    2ND TALENTA CONFERENCE ON ENGINEERING, SCIENCE AND TECHNOLOGY, 2020, 801
  • [45] Clinical Comparative Study for Validation of Digital Impression Reliability with the Gypsum Check: A Simple and Fast Way to Evaluate the Trueness and Accuracy of Implant-Supported Rehabilitation
    Barile, Giuseppe
    de Rosa, Giovanni
    Papadia, Paride
    Muci, Giovannino
    Capodiferro, Saverio
    Corsalini, Massimo
    APPLIED SCIENCES-BASEL, 2023, 13 (13):
  • [46] A SIMPLE AND NONINVASIVE TEST FOR THE EVALUATION OF VITAMIN-A RESERVES - THE OCULAR IMPRESSION
    AMEDEEMANESME, O
    LUZEAU, R
    GASTROENTEROLOGIE CLINIQUE ET BIOLOGIQUE, 1987, 11 (2BIS): : A103 - A103
  • [47] Response to the letter to the editor "Evaluating the impact of scan aid color on digital scan trueness: Insights and recommendations"
    Onoral, Ozay
    Cakir, Selin
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2025, 34 (03): : 229 - 231
  • [48] Robust Evaluation of Reference Tilt in Digital Holography
    Xu, Xianfeng
    Wang, Hao
    Sheng, Hui
    Luo, Weilong
    Wang, Xinwei
    APPLIED SCIENCES-BASEL, 2022, 12 (21):
  • [49] The evaluation of worldwide digital reference services in libraries
    Smith, Alastair G.
    ELECTRONIC LIBRARY, 2008, 26 (03): : 425 - 426
  • [50] Digital reference services: Framework for analysis and evaluation
    White, MD
    LIBRARY & INFORMATION SCIENCE RESEARCH, 2001, 23 (03) : 211 - 231