Trueness evaluation of digital impression: The impact of the selection of reference and test object

被引:16
|
作者
Yatmaz, Berfin Bahar [1 ]
Raith, Stefan [1 ]
Reich, Sven [1 ]
机构
[1] Rhein Westfal TH Aachen, Dept Prosthodont & Biomat, Subject & Res Area Computerized Dent, Pauwelsstr 30, D-52074 Aachen, Germany
关键词
Trueness; Evaluation; 3D comparison; Digital; Intraoral; Scanner; ACCURACY; SYSTEMS;
D O I
10.1016/j.jdent.2021.103706
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: This study evaluated the importance of defining the reference and the test object during 3D surface comparisons to assess the trueness of an intraoral scanner. Materials and methods: A maxillary complete-arch cast with interdental spaces was digitized with a high resolution scanner to obtain the ground truth dataset [GT]. Fifteen intraoral scanning datasets [IOS] were obtained with an intraoral scanner. The trueness of the [IOS] datasets were evaluated by two different comparison procedures using a 3D analysis software: In the first comparison [REF-GT], the [GT] dataset was set as reference object and the [IOS] dataset was defined as test object. In the second comparison [REF-IOS], the [IOS] dataset were set as reference object and the [GT] dataset was defined as test object. The mean trueness of both comparisons was calculated with absolute mean deviation, (90-10)/2 percentile, and root-mean-squared (RMS) error method. Statistical significance was analyzed using the t-test (alpha=0.05). Results: The mean trueness values of [REF-GT] were 31.4(+/- 6.1) mu m for (90-10)/2 percentile, 77.0(+/- 5.3) mu m for absolute mean deviation, and 203.1(+/- 4.8) mu m for RMS error method. [REF-IOS] revealed 23.9(+/- 4.8) mu m, 28.3 (+/- 6.3) mu m, and 39.6(+/- 9.5) mu m, respectively. The results differed significantly. Conclusion: The datasets obtained from the intraoral scanner captured more adequately interproximal spaces in comparison to the [GT] dataset. Therefore, the [GT] dataset defined as reference object in the analysis software for 3D comparisons revealed misleading results. Clinical significance: The selection of the reference object and of the areas to be compared have to be defined carefully regarding complete arch scanning accuracy analysis.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Evaluation of software for reading images of the CDMAM test object to assess digital mammography systems
    Young, Kenneth C.
    Alsager, Abdulaziz
    Oduko, Jennifer M.
    Bosmans, Hilde
    Verbrugge, Beatrijs
    Geertse, Tanya
    van Engene, Ruben
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [22] Adaptive Selection of Reference Frames for Video Object Segmentation
    Hong, Lingyi
    Zhang, Wei
    Chen, Liangyu
    Zhang, Wenqiang
    Fan, Jianping
    IEEE TRANSACTIONS ON IMAGE PROCESSING, 2022, 31 : 1057 - 1071
  • [23] Digital evaluation of the accuracy of impression techniques and materials in angulated implants
    Kurtulmus-Yilmaz, Sevcan
    Ozan, Oguz
    Ozcelik, Tuncer Burak
    Yagiz, Ayberk
    JOURNAL OF DENTISTRY, 2014, 42 (12) : 1551 - 1559
  • [24] Evaluation of the Accuracy of Conventional and Digital Impression Techniques for Implant Restorations
    Moura, Renata Vasconcellos
    Kojima, Alberto Noriyuki
    Coury Saraceni, Cintia Helena
    Bassolli, Lucas
    Balducci, Ivan
    Ozcan, Mutlu
    Melo Mesquita, Alfredo Mikail
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (02): : E530 - E535
  • [25] Digital reference object toolkit of breast DCE MRI for quantitative evaluation of image reconstruction and analysis methods
    Bae, Jonghyun
    Tan, Zhengguo
    Solomon, Eddy
    Huang, Zhengnan
    Heacock, Laura
    Moy, Linda
    Knoll, Florian
    Kim, Sungheon Gene
    MAGNETIC RESONANCE IN MEDICINE, 2024, 92 (04) : 1728 - 1742
  • [26] Evaluation of Trueness and Precision of a Bench-Top Laboratory Glucose Analyzer Using Reference Materials
    Baumstark, Annette
    Pleus, Stefan
    Hartwig, Matthias
    Freckmann, Guido
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2022, 16 (03): : 751 - 755
  • [27] AN EVALUATION OF THE IMPRESSION TEST FOR ESTIMATING THE TENSILE PROPERTIES OF METALLIC MATERIALS
    JONES, HN
    JOURNAL OF TESTING AND EVALUATION, 1992, 20 (06) : 403 - 407
  • [28] Evaluation of conversion relationships for impression creep test at elevated temperatures
    Hyde, T. H.
    Sun, W.
    INTERNATIONAL JOURNAL OF PRESSURE VESSELS AND PIPING, 2009, 86 (11) : 757 - 763
  • [29] Digital reference: services, attitudes, and evaluation
    不详
    INTERNET RESEARCH, 2000, 10 (03) : 256 - 258
  • [30] A TEST OBJECT FOR EVALUATION OF PORTAL FILMS
    LUTZ, WR
    BJARNGARD, BE