Trueness evaluation of digital impression: The impact of the selection of reference and test object

被引:16
|
作者
Yatmaz, Berfin Bahar [1 ]
Raith, Stefan [1 ]
Reich, Sven [1 ]
机构
[1] Rhein Westfal TH Aachen, Dept Prosthodont & Biomat, Subject & Res Area Computerized Dent, Pauwelsstr 30, D-52074 Aachen, Germany
关键词
Trueness; Evaluation; 3D comparison; Digital; Intraoral; Scanner; ACCURACY; SYSTEMS;
D O I
10.1016/j.jdent.2021.103706
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: This study evaluated the importance of defining the reference and the test object during 3D surface comparisons to assess the trueness of an intraoral scanner. Materials and methods: A maxillary complete-arch cast with interdental spaces was digitized with a high resolution scanner to obtain the ground truth dataset [GT]. Fifteen intraoral scanning datasets [IOS] were obtained with an intraoral scanner. The trueness of the [IOS] datasets were evaluated by two different comparison procedures using a 3D analysis software: In the first comparison [REF-GT], the [GT] dataset was set as reference object and the [IOS] dataset was defined as test object. In the second comparison [REF-IOS], the [IOS] dataset were set as reference object and the [GT] dataset was defined as test object. The mean trueness of both comparisons was calculated with absolute mean deviation, (90-10)/2 percentile, and root-mean-squared (RMS) error method. Statistical significance was analyzed using the t-test (alpha=0.05). Results: The mean trueness values of [REF-GT] were 31.4(+/- 6.1) mu m for (90-10)/2 percentile, 77.0(+/- 5.3) mu m for absolute mean deviation, and 203.1(+/- 4.8) mu m for RMS error method. [REF-IOS] revealed 23.9(+/- 4.8) mu m, 28.3 (+/- 6.3) mu m, and 39.6(+/- 9.5) mu m, respectively. The results differed significantly. Conclusion: The datasets obtained from the intraoral scanner captured more adequately interproximal spaces in comparison to the [GT] dataset. Therefore, the [GT] dataset defined as reference object in the analysis software for 3D comparisons revealed misleading results. Clinical significance: The selection of the reference object and of the areas to be compared have to be defined carefully regarding complete arch scanning accuracy analysis.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] An Influence Model for Reference Object Selection in Spatially Locative Phrases
    Barclay, Michael
    Galton, Antony
    SPATIAL COGNITION VI: LEARNING, REASONING, AND TALKING ABOUT SPACE, 2008, 5248 : 216 - 232
  • [32] Impact of digital impression techniques on the adaption of ceramic partial crowns in vitro
    Schaefer, Oliver
    Decker, Mike
    Wittstock, Frank
    Kuepper, Harald
    Guentsch, Arndt
    JOURNAL OF DENTISTRY, 2014, 42 (06) : 677 - 683
  • [33] Evaluation of the Trueness of Digital Implant Impressions According to the Implant Scan Body Orientation and Scanning Method
    Lee, Bora
    Nam, Na-Eun
    Shin, Seung-Ho
    Lim, Jung-Hwa
    Shim, June-Sung
    Kim, Jong-Eun
    APPLIED SCIENCES-BASEL, 2021, 11 (07):
  • [35] Statistical evaluation of the learning curve in digital impression in different types of operators
    Ferrini, F.
    La Rocca, S.
    La Rocca, G.
    Speroni, S.
    Cantile, N.
    Gastaldi, G.
    JOURNAL OF OSSEOINTEGRATION, 2025, 17 (01) : 23 - 33
  • [36] Evaluation of the accuracy of multiple digital impression systems on a fully edentulous maxilla
    Gutmacher, Zvi
    Kelly, Abigail
    Renne, Walter
    Hoover, Madison
    Mennito, Anthony
    Teich, Sorin
    Cayouette, Monica
    Ludlow, Mark
    QUINTESSENCE INTERNATIONAL, 2021, 52 (06): : 488 - 495
  • [37] Digital Evaluation of the Dimensional Accuracy of Four Different Implant Impression Techniques
    Ozcelik, T. B.
    Ozcan, I.
    Ozan, O.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2018, 21 (10) : 1247 - 1253
  • [38] Modal test reference selection using an SVD procedure
    Avitabile, P
    Haselton, D
    Moore, J
    PROCEEDINGS OF THE 14TH INTERNATIONAL MODAL ANALYSIS CONFERENCE, VOLS I & II, 1996, 2768 : 1527 - 1532
  • [39] The impact of digital reference on librarians and library users
    Tenopir, C
    Ennis, L
    ONLINE, 1998, 22 (06): : 84 - +
  • [40] Impact of digital reference on librarians and library users
    Tenopir, Carol
    Ennis, Lisa
    Online (Wilton, Connecticut), 1998, 22 (06):