Utility of the Novel MediPost Mobile Posturography Device in the Assessment of Patients with a Unilateral Vestibular Disorder

被引:6
|
作者
Rosiak, Oskar [1 ]
Gawronska, Anna [1 ]
Janc, Magdalena [2 ]
Marciniak, Pawel [3 ]
Kotas, Rafal [3 ]
Zamyslowska-Szmytke, Ewa [2 ]
Jozefowicz-Korczynska, Magdalena [1 ]
机构
[1] Med Univ Lodz, Norbert Barlicki Mem Teaching Hosp, Dept Otolaryngol, Balance Disorders Unit, PL-90153 Lodz, Poland
[2] Nofer Inst Occupat Med, Audiol & Phoniatr Clin, PL-91348 Lodz, Poland
[3] Lodz Univ Technol, Dept Microelect & Comp Sci, PL-90924 Lodz, Poland
关键词
mobile posturography; vertigo; balance disorders; body-worn sensors; intraclass correlation coefficients; Bland-Altmann; SENSORY INTEGRATION; BALANCE DISORDERS; CLINICAL UTILITY; RELIABILITY; POSTURE; GAIT;
D O I
10.3390/s22062208
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Balance disorders are a growing problem worldwide. Thus, there is an increasing need to provide an inexpensive and feasible alternative to standard posturographic platforms (SP) used for the assessment of balance and to provide a possible solution for telemonitoring of patients. A novel mobile posturography (MP) MediPost device was developed to address these issues. This prospective study used a Modified Clinical Test of Sensory Interaction on Balance to evaluate healthy individuals and patients with a unilateral vestibular disorder through SP and MP simultaneously. The control group included 65 healthy volunteers, while the study group included 38 patients diagnosed with a unilateral vestibular deficit. The angular velocity values obtained from both methods were compared by intraclass correlation coefficients (ICC) and Bland-Altman plot analysis. Diagnostic capabilities were measured in terms of sensitivity and specificity. The ICC between the two methods for conditions 2-4 was indicative of excellent reliability, with the ICC > 0.9 (p < 0.001), except for Condition 1 (standing stance, eyes open) ICC = 0.685, p < 0.001, which is indicative of moderate reliability. ROC curve analysis of angular velocity for condition 4 represents the most accurate differentiating factor with AUC values of 0.939 for SP and 0.953 for MP. This condition also reported the highest sensitivity, specificity, PPV, and NPV values with 86.4%, 87.7%, 80%, and 90.5% for SP, and 92.1%, 84.6%, 77.8%, and 94.8% for MP, respectively. The newly developed MediPost device has high sensitivity and specificity in distinguishing between healthy individuals and patients with a unilateral vestibular deficit.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Validity and Responsiveness of a Modified Balance Error Scoring System Assessment Using a Mobile Device Application in Patients Recovering from Ankle Sprain
    Crowell, Michael S.
    Thomasma, Eliot
    Florkiewicz, Erin
    Brindle, Richard
    Roach, Megan
    Goss, Donald
    Pitt, Will
    INTERNATIONAL JOURNAL OF SPORTS PHYSICAL THERAPY, 2024, 19 (04): : 440 - 450
  • [42] Prolonged ECG with a novel recorder utilizing electrode belt and mobile device in patients with recent embolic stroke of undetermined source: A pilot study
    Lumikari, Tuomas Jussi
    Pirinen, Jani
    Putaala, Jukka
    Sibolt, Gerli
    Kerola, Anne
    Pakarinen, Sami
    Lehto, Mika
    Nieminen, Tuomo
    ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, 2020, 25 (06)
  • [43] Clinical Utility of a Novel Coronary Heart Disease Risk-Assessment Test to Further Classify Intermediate-Risk Patients
    Solomon, Matthew D.
    Tirupsur, Ahalya
    Hytopoulos, Evangelos
    Beggs, Michael
    Harrington, Douglas S.
    French, Cynthia
    Quertermous, Thomas
    CLINICAL CARDIOLOGY, 2013, 36 (10) : 621 - 627
  • [44] Assessment of Eyelid Pressure Using a Novel Pressure Measurement Device in Patients With Moderate-to-Severe Dry Eye Disease
    Wang, Jingyi
    Bao, Jiayu
    Song, Wenxiu
    Li, Siyuan
    Hao, Yiran
    Tian, Lei
    Jie, Ying
    FRONTIERS IN MEDICINE, 2022, 9
  • [45] Prospective assessment of lower-extremity peripheral arterial disease in diabetic patients using a novel automated optical device
    Alnaeb, Mohamad E.
    Crabtree, Vincent P.
    Boutin, Adrien
    Mikhailidis, Dimitri P.
    Seifalian, Alexander M.
    Hamilton, George
    ANGIOLOGY, 2007, 58 (05) : 579 - 585
  • [46] Cloud Storage Based Mobile Assessment Facility for Patients with Post-Traumatic Stress Disorder Using Integrated Signal Processing Algorithm
    Balbin, Jessie R.
    Pinugu, Jasmine Nadja J.
    Basco, Abigail Joy S.
    Cabanada, Myla B.
    Gonzales, Patrisha Melrose V.
    Marasigan, Juan Carlos C.
    SECOND INTERNATIONAL WORKSHOP ON PATTERN RECOGNITION, 2017, 10443
  • [47] Utility of the PFA-100 Instrument and the Novel Multiplate Analyzer for the Assessment of Aspirin and Clopidogrel Effects on Platelet Function in Patients With Cardiovascular Disease
    Mueller, Thomas
    Dieplinger, Benjamin
    Poelz, Werner
    Haltmayer, Meinhard
    CLINICAL AND APPLIED THROMBOSIS-HEMOSTASIS, 2009, 15 (06) : 652 - 659
  • [48] Assessment of mental health, knowledge, and attitude of patients with multiple sclerosis and neuromyelitis optica spectrum disorder in response to 2019 novel coronavirus
    Vahid Shaygannejad
    Alireza Afshari-Safavi
    Boshra Hatef
    Neurological Sciences, 2021, 42 : 2891 - 2901
  • [49] Assessment of Shared Neurologic Radiomic Markers Among Patients Diagnosed with Functional Seizure Disorder Utilizing a Novel Machine Learning Model
    Moss, Jonah
    Schmid, Elizabeth
    Ovalle, Adriana Bermeo
    Stoub, Travis
    O'Dwyer, Rebecca
    NEUROLOGY, 2023, 100 (17)
  • [50] Assessment of mental health, knowledge, and attitude of patients with multiple sclerosis and neuromyelitis optica spectrum disorder in response to 2019 novel coronavirus
    Shaygannejad, Vahid
    Afshari-Safavi, Alireza
    Hatef, Boshra
    NEUROLOGICAL SCIENCES, 2021, 42 (07) : 2891 - 2901