Utility of the Novel MediPost Mobile Posturography Device in the Assessment of Patients with a Unilateral Vestibular Disorder

被引:6
|
作者
Rosiak, Oskar [1 ]
Gawronska, Anna [1 ]
Janc, Magdalena [2 ]
Marciniak, Pawel [3 ]
Kotas, Rafal [3 ]
Zamyslowska-Szmytke, Ewa [2 ]
Jozefowicz-Korczynska, Magdalena [1 ]
机构
[1] Med Univ Lodz, Norbert Barlicki Mem Teaching Hosp, Dept Otolaryngol, Balance Disorders Unit, PL-90153 Lodz, Poland
[2] Nofer Inst Occupat Med, Audiol & Phoniatr Clin, PL-91348 Lodz, Poland
[3] Lodz Univ Technol, Dept Microelect & Comp Sci, PL-90924 Lodz, Poland
关键词
mobile posturography; vertigo; balance disorders; body-worn sensors; intraclass correlation coefficients; Bland-Altmann; SENSORY INTEGRATION; BALANCE DISORDERS; CLINICAL UTILITY; RELIABILITY; POSTURE; GAIT;
D O I
10.3390/s22062208
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Balance disorders are a growing problem worldwide. Thus, there is an increasing need to provide an inexpensive and feasible alternative to standard posturographic platforms (SP) used for the assessment of balance and to provide a possible solution for telemonitoring of patients. A novel mobile posturography (MP) MediPost device was developed to address these issues. This prospective study used a Modified Clinical Test of Sensory Interaction on Balance to evaluate healthy individuals and patients with a unilateral vestibular disorder through SP and MP simultaneously. The control group included 65 healthy volunteers, while the study group included 38 patients diagnosed with a unilateral vestibular deficit. The angular velocity values obtained from both methods were compared by intraclass correlation coefficients (ICC) and Bland-Altman plot analysis. Diagnostic capabilities were measured in terms of sensitivity and specificity. The ICC between the two methods for conditions 2-4 was indicative of excellent reliability, with the ICC > 0.9 (p < 0.001), except for Condition 1 (standing stance, eyes open) ICC = 0.685, p < 0.001, which is indicative of moderate reliability. ROC curve analysis of angular velocity for condition 4 represents the most accurate differentiating factor with AUC values of 0.939 for SP and 0.953 for MP. This condition also reported the highest sensitivity, specificity, PPV, and NPV values with 86.4%, 87.7%, 80%, and 90.5% for SP, and 92.1%, 84.6%, 77.8%, and 94.8% for MP, respectively. The newly developed MediPost device has high sensitivity and specificity in distinguishing between healthy individuals and patients with a unilateral vestibular deficit.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Soft Tissue Assessment of Acute Trauma Patients Using a New Novel Non Invasive Device
    Rosenberg, M. S.
    Zigrossi, D.
    Giordano, P. A.
    Weber, K.
    Steinberg, B.
    ANNALS OF EMERGENCY MEDICINE, 2013, 62 (04) : S65 - S65
  • [32] Utility of Washington Early Recognition Center Self-Report Screening Questionnaires in the Assessment of Patients with Schizophrenia and Bipolar Disorder
    Hsieh, Christina J.
    Godwin, Douglass
    Mamah, Daniel
    FRONTIERS IN PSYCHIATRY, 2016, 7
  • [33] Use of Wearable Sensor Device and Mobile Application for Objective Assessment of Pain in Post-surgical Patients: A Preliminary Study
    Wibowo, Sandi
    Chaw, Wei Liang
    Antuvan, Chris Wilson
    Hao, Chen
    2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC, 2023,
  • [34] Assessment of patient acceptability of Respiratory Rate measurement in severely obese patients using the novel RespiraSense device
    Albon, Lorraine
    Baryshpoelec, Sonia
    Cowpe, Samantha
    Longstaff, Jayne
    Thomas, Denise
    Kinsella, Sean
    Chauhan, Anoop
    OBESITY SURGERY, 2019, 29 : S28 - S28
  • [35] FEASIBILITY STUDY TO EVALUATE THE SAFETY AND UTILITY OF A NOVEL CIRCUMFERENTIAL IMAGING DEVICE TO VISUALIZE THE ANAL CANAL IN PATIENTS WITH ANAL DYSPLASIA.
    White, M.
    Lin, J.
    Yang, C.
    Lai, L.
    DISEASES OF THE COLON & RECTUM, 2016, 59 (05) : E194 - E195
  • [36] Accuracy of visual acuity assessment using a novel smartphone-coupled device in patients with eye pathology
    McKelvie, James
    McLintock, Cameron
    Scott, Daniel
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2019, 47 : 48 - 48
  • [37] Performance assessment of a novel medical device for home monitoring of CPAP treatment in patients with obstructive sleep apnoea syndrome
    Texereau, Joelle
    Elbaz, Maxime
    Carron, Amelie
    Piednoir, Benoit
    Taupin, Henry
    Weber, Claude
    Leger, Damien
    EUROPEAN RESPIRATORY JOURNAL, 2013, 42
  • [38] The Utility of Metal Artifact Reduction Techniques in the Postoperative Assessment of a Novel Tantalum Intervertebral Spacer Device on 3 T Magnetic Resonance Imaging: An In Vitro Study
    Macdonald, Mark
    Ferguson, John
    Munro, Jacob
    Reilly, Keryn
    Cornish, Jillian
    Konz, Gina
    Champion, Andrea
    Lee, Arier C.
    Deib, Gerard
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2015, 9 (03):
  • [39] Assessment of the validity and feasibility of a novel virtual reality test of emotion regulation in patients with bipolar disorder and their unaffected relatives
    Kjaerstad, Hanne Lie
    Hellum, Karin Schioler
    Haslum, Nora Hilde
    Lopes, Mads Nathaniel
    Noer, Thomas Saaby
    Kessing, Lars Vedel
    Miskowiak, Kamilla Woznica
    JOURNAL OF AFFECTIVE DISORDERS, 2022, 318 : 217 - 223
  • [40] Utility of cardiac computed tomography for inflow cannula patency assessment and prediction of clinical outcome in patients with the HeartMate II left ventricular assist device
    Sacks, Justin
    Gonzalez-Stawinski, Gonzalo V.
    Hall, Shelley
    Lima, Brian
    MacHannaford, Juan
    Dockery, William
    Cura, Marco
    Chamogeorgakis, Themistokles
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2015, 21 (05) : 590 - 593