Clinical Application of Dual-Energy Spectral Computed Tomography in Detecting Cholesterol Gallstones From Surrounding Bile

被引:43
|
作者
Yang, Chuang-bo [1 ]
Zhang, Shuang [2 ]
Jia, Yong-jun [1 ]
Duan, Hai-feng [1 ]
Ma, Guang-ming [1 ]
Zhang, Xi-rong [1 ]
Yu, Yong [1 ]
He, Tai-ping [1 ]
机构
[1] Shaanxi Univ Chinese Med, Affiliated Hosp, Dept Diagnost Radiol, Weiyang Western Rd 2, Xianyang 712000, Peoples R China
[2] Shaanxi Inst Int Trade & Commerce, Sch Med, Dept Basic Chem, Xian 712046, Shaanxi, Peoples R China
关键词
Tomography; X-ray computed; dual-energy CT; material decomposition; cholesterol gallstones; IN-VITRO; CT; CHOLEDOCHOLITHIASIS; EXPERIENCE; VIVO;
D O I
10.1016/j.acra.2016.10.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objective: This study aimed to investigate the clinical value of spectral computed tomography (CT) in the detection of cholesterol gallstones from surrounding bile. Materials and Methods: This study was approved by the institutional review board. The unenhanced spectral CT data of 24 patients who had surgically confirmed cholesterol gallstones were analyzed. Lipid concentrations and CT numbers were measured from fat based material decomposition image and virtual monochromatic image sets (40-140 keV), respectively. The difference in lipid concentration and CT number between cholesterol gallstones and the surrounding bile were statistically analyzed. Receiver operating characteristic analysis was applied to determine the diagnostic accuracy of using lipid concentration to differentiate cholesterol gallstones from bile. Results: Cholesterol gallstones were bright on fat-based material decomposition images yielding a 92% detection rate (22 of 24). The lipid concentrations (552.65 +/- 262.36 mg/mL), CT number at 40 keV (-31.57 +/- 16.88 HU) and 140 keV (24.30 +/- 5.85 HU) for the cholesterol gallstones were significantly different from those of bile (-13.94 +/- 105.12 mg/mL; 12.99 +/- 9.39 HU and 6.19 +/- 4.97 HU, respectively). Using 182.59 mg/mL as the threshold value for lipid concentration, one could obtain sensitivity of 95.5% and specificity of 100% with accuracy of 0:994 for differentiating cholesterol gallstones tom bile. Conclusions: Virtual monochromatic. spectral CT images at 40 keV and 140 keV provide significant CT number differences between, cholesterol gallstones and the surrounding bile. Spectral CT provides an excellent detection rate for cholesterol gallstones.
引用
收藏
页码:478 / 482
页数:5
相关论文
共 50 条
  • [41] Dual-energy Computed Tomography Applications in Uroradiology
    Jong Park
    Hersh Chandarana
    Michael Macari
    Alec J. Megibow
    Current Urology Reports, 2012, 13 : 55 - 62
  • [42] Dual-energy Computed Tomography Imaging of the Aorta
    Vlahos, Ioannis
    Godoy, Myrna C. B.
    Naidich, David P.
    JOURNAL OF THORACIC IMAGING, 2010, 25 (04) : 289 - 300
  • [43] Dual-Energy Computed Tomography in Body Imaging
    Toia, Giuseppe V.
    Kim, Sooah
    Dighe, Manjiri K.
    Mileto, Achille
    SEMINARS IN ROENTGENOLOGY, 2018, 53 (02) : 132 - 146
  • [44] Dual-Energy Computed Tomography Technology and Challenges
    Krauss, Bernhard
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2018, 56 (04) : 497 - +
  • [45] Dual-Energy Computed Tomography Applications in Rheumatology
    Park, Eun Hae
    O'Donnell, Thomas
    Fritz, Jan
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2024, 62 (05) : 849 - 863
  • [46] Vascular Applications of Dual-Energy Computed Tomography
    Rajiah, Prabhakar S.
    Kambadakone, Avinash
    Ananthakrishnan, Lakshmi
    Sutphin, Patrick
    Kalva, Sanjeeva P.
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2023, 61 (06) : 1011 - 1029
  • [47] Dual-Energy Computed Tomography Applications in Neurointervention
    Wolman, Dylan N.
    Patel, Bhavik P.
    Wintermark, Max
    Heit, Jeremy J.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (06) : 831 - 839
  • [48] Cardiac Applications of Dual-Energy Computed Tomography
    Lempel, Matthew
    Frishman, William H.
    CARDIOLOGY IN REVIEW, 2019, 27 (04) : 208 - 210
  • [49] Dual-energy computed tomography: pediatric considerations
    Gallo-Bernal, Sebastian
    Pena-Trujillo, Valeria
    Gee, Michael S.
    PEDIATRIC RADIOLOGY, 2024, 54 (13) : 2112 - 2126
  • [50] Virtual Monochromatic Image Quality from Dual-Layer Dual-Energy Computed Tomography for Detecting Brain Tumors
    Tanoue, Shota
    Nakaura, Takeshi
    Nagayama, Yasunori
    Uetani, Hiroyuki
    Ikeda, Osamu
    Yamashita, Yasuyuki
    KOREAN JOURNAL OF RADIOLOGY, 2021, 22 (06) : 951 - 958