Clinical Application of Dual-Energy Spectral Computed Tomography in Detecting Cholesterol Gallstones From Surrounding Bile

被引:43
|
作者
Yang, Chuang-bo [1 ]
Zhang, Shuang [2 ]
Jia, Yong-jun [1 ]
Duan, Hai-feng [1 ]
Ma, Guang-ming [1 ]
Zhang, Xi-rong [1 ]
Yu, Yong [1 ]
He, Tai-ping [1 ]
机构
[1] Shaanxi Univ Chinese Med, Affiliated Hosp, Dept Diagnost Radiol, Weiyang Western Rd 2, Xianyang 712000, Peoples R China
[2] Shaanxi Inst Int Trade & Commerce, Sch Med, Dept Basic Chem, Xian 712046, Shaanxi, Peoples R China
关键词
Tomography; X-ray computed; dual-energy CT; material decomposition; cholesterol gallstones; IN-VITRO; CT; CHOLEDOCHOLITHIASIS; EXPERIENCE; VIVO;
D O I
10.1016/j.acra.2016.10.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objective: This study aimed to investigate the clinical value of spectral computed tomography (CT) in the detection of cholesterol gallstones from surrounding bile. Materials and Methods: This study was approved by the institutional review board. The unenhanced spectral CT data of 24 patients who had surgically confirmed cholesterol gallstones were analyzed. Lipid concentrations and CT numbers were measured from fat based material decomposition image and virtual monochromatic image sets (40-140 keV), respectively. The difference in lipid concentration and CT number between cholesterol gallstones and the surrounding bile were statistically analyzed. Receiver operating characteristic analysis was applied to determine the diagnostic accuracy of using lipid concentration to differentiate cholesterol gallstones from bile. Results: Cholesterol gallstones were bright on fat-based material decomposition images yielding a 92% detection rate (22 of 24). The lipid concentrations (552.65 +/- 262.36 mg/mL), CT number at 40 keV (-31.57 +/- 16.88 HU) and 140 keV (24.30 +/- 5.85 HU) for the cholesterol gallstones were significantly different from those of bile (-13.94 +/- 105.12 mg/mL; 12.99 +/- 9.39 HU and 6.19 +/- 4.97 HU, respectively). Using 182.59 mg/mL as the threshold value for lipid concentration, one could obtain sensitivity of 95.5% and specificity of 100% with accuracy of 0:994 for differentiating cholesterol gallstones tom bile. Conclusions: Virtual monochromatic. spectral CT images at 40 keV and 140 keV provide significant CT number differences between, cholesterol gallstones and the surrounding bile. Spectral CT provides an excellent detection rate for cholesterol gallstones.
引用
收藏
页码:478 / 482
页数:5
相关论文
共 50 条
  • [21] Dual-Energy Computed Tomography: Integration Into Clinical Practice and Cost Considerations
    Ananthakrishnan, Lakshmi
    Kulkarni, Naveen
    Toshav, Aran
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2023, 61 (06) : 963 - 971
  • [22] Feasibility of computed tomography texture analysis of hepatic fibrosis using dual-energy spectral detector computed tomography
    Choi, ByukGyung
    Choi, In Young
    Cha, Sang Hoon
    Yeom, Suk Keu
    Chung, Hwan Hoon
    Lee, Seung Hwa
    Cha, Jaehyung
    Lee, Ju-Han
    JAPANESE JOURNAL OF RADIOLOGY, 2020, 38 (12) : 1179 - 1189
  • [23] Feasibility of computed tomography texture analysis of hepatic fibrosis using dual-energy spectral detector computed tomography
    ByukGyung Choi
    In Young Choi
    Sang Hoon Cha
    Suk Keu Yeom
    Hwan Hoon Chung
    Seung Hwa Lee
    Jaehyung Cha
    Ju-Han Lee
    Japanese Journal of Radiology, 2020, 38 : 1179 - 1189
  • [24] Dual-Energy Computed Tomography of the Liver: Uses in Clinical Practices and Applications
    Tsurusaki, Masakatsu
    Sofue, Keitaro
    Hori, Masatoshi
    Sasaki, Kosuke
    Ishii, Kazunari
    Murakami, Takamichi
    Kudo, Masatoshi
    DIAGNOSTICS, 2021, 11 (02)
  • [25] Clinical Applications of Dual-Energy Computed Tomography for Acute Ischemic Stroke
    Chen, Huanwen
    Bodanapally, Uttam K.
    Colasurdo, Marco
    Malhotra, Ajay
    Gandhi, Dheeraj
    STROKE-VASCULAR AND INTERVENTIONAL NEUROLOGY, 2024, 4 (02):
  • [26] Characterization of ureteral stents by dual-energy computed tomography: Clinical implications
    Ibrahim, El-Sayed H.
    Haley, William E.
    Jepperson, Maria A.
    Wehle, Michael J.
    Cernigliaro, Joseph G.
    WORLD JOURNAL OF RADIOLOGY, 2014, 6 (08): : 625 - 628
  • [27] Development of Cu application using dual-energy computed tomography for detecting medication-related osteonecrosis of the jaw
    Shigenaga, Kazuki
    Arimoto, Satomi
    Kubo, Masahiro
    Sato, Takumi
    Hiraoka, Yujiro
    Takeda, Daisuke
    Hasegawa, Takumi
    Kagawa, Kiyosumi
    Akashi, Masaya
    JOURNAL OF BONE AND MINERAL METABOLISM, 2023, 41 (06) : 865 - 876
  • [28] Development of Cu application using dual-energy computed tomography for detecting medication-related osteonecrosis of the jaw
    Kazuki Shigenaga
    Satomi Arimoto
    Masahiro Kubo
    Takumi Sato
    Yujiro Hiraoka
    Daisuke Takeda
    Takumi Hasegawa
    Kiyosumi Kagawa
    Masaya Akashi
    Journal of Bone and Mineral Metabolism, 2023, 41 : 865 - 876
  • [29] Dual-energy computed tomography diagnostics for gout
    Rech, H. J.
    Cavallaro, A.
    ZEITSCHRIFT FUR RHEUMATOLOGIE, 2017, 76 (07): : 580 - 588
  • [30] Imaging of nanoparticles with dual-energy computed tomography
    Ducote, J. L.
    Alivov, Y.
    Molloi, S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (07): : 2031 - 2044