Virtual Monochromatic Image Quality from Dual-Layer Dual-Energy Computed Tomography for Detecting Brain Tumors

被引:9
|
作者
Tanoue, Shota [1 ]
Nakaura, Takeshi [1 ]
Nagayama, Yasunori [1 ]
Uetani, Hiroyuki [1 ]
Ikeda, Osamu [1 ]
Yamashita, Yasuyuki [1 ]
机构
[1] Kumamoto Univ, Grad Sch Med Sci, Dept Diagnost Radiol, Honjo 1-1-1, Kumamoto, Kumamoto 8608556, Japan
关键词
Tomography; X-ray computed; Radiography; Dual-energy scanned projection; Image enhancement; Brain neoplasms; HEAD CT; 120; KVP; RECONSTRUCTION; CONTRAST; HEMORRHAGE; VOLTAGE;
D O I
10.3348/kjr.2020.0677
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To evaluate the usefulness of virtual monochromatic images (VMIs) obtained using dual-layer dual-energy CT (DL-DECT) for evaluating brain tumors. Materials and Methods: This retrospective study included 32 patients with brain tumors who had undergone non-contrast head CT using DL-DECT. Among them, 15 had glioblastoma (GBM), 7 had malignant lymphoma, 5 had high-grade glioma other than GBM, 3 had low-grade glioma, and 2 had metastatic tumors. Conventional polychromatic images and VMIs (40-200 keV at 10 keV intervals) were generated. We compared CT attenuation, image noise, contrast, and contrast-to-noise ratio (CNR) between tumor and white matter (WM) or grey matter (GM) between VMIs showing the highest CNR (optimized VMI) and conventional CT images using the paired t test. Two radiologists subjectively assessed the contrast, margin, noise, artifact, and diagnostic confidence of optimized VMIs and conventional images on a 4-point scale. Results: The image noise of VMIs at all energy levels tested was significantly lower than that of conventional CT images (p < 0.05). The 40-keV VMIs yielded the best CNR. Furthermore, both contrast and CNR between the tumor and WM were significantly higher in the 40 keV images than in the conventional CT images (p < 0.001); however, the contrast and CNR between tumor and GM were not significantly different (p = 0.47 and p = 0.31, respectively). The subjective scores assigned to contrast, margin, and diagnostic confidence were significantly higher for 40 keV images than for conventional CT images (p < 0.01). Conclusion: In head CT for patients with brain tumors, compared with conventional CT images, 40 keV VMIs from DL-DECT yielded superior tumor contrast and diagnostic confidence, especially for brain tumors located in the WM.
引用
收藏
页码:951 / 958
页数:8
相关论文
共 50 条
  • [1] Dual-energy computed tomography colonography using dual-layer spectral detector computed tomography: Utility of virtual monochromatic imaging for electronic cleansing
    Taguchi, Narumi
    Oda, Seitaro
    Imuta, Masanori
    Yamamura, Sadahiro
    Yokota, Yasuhiro
    Nakaura, Takeshi
    Nagayama, Yasunori
    Kidoh, Masafumi
    Utsunomiya, Daisuke
    Funama, Yoshinori
    Baba, Hideo
    Yamashita, Yasuyuki
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 108 : 7 - 12
  • [2] Accuracy of Quantification of Iodine and Hounsfield Unit Values on Virtual Monochromatic Imaging Using Dual-Energy Computed Tomography: Comparison of Dual-Layer Computed Tomography With Fast Kilovolt-Switching Computed Tomography
    Washio, Hayate
    Ohira, Shingo
    Karino, Tsukasa
    Nitta, Yuya
    Hayashi, Masaaki
    Miyazaki, Masayoshi
    Teshima, Teruki
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (06) : 965 - 971
  • [3] Comparing image quality of single- and dual-energy computed tomography of the brain
    Dodig, Doris
    Kovacic, Slavica
    Matana Kastelan, Zrinka
    Zuza, Iva
    Benic, Filip
    Slaven, Jurkovic
    Miletic, Damir
    Rumboldt, Zoran
    NEURORADIOLOGY JOURNAL, 2020, 33 (03): : 259 - 266
  • [4] Value of the virtual monoenergetic image from dual-layer dual-energy computed tomography enterography in the preoperative assessment of the internal penetrating complication of Crohn's disease
    Gong, Meilin
    Liu, Lili
    Ren, Huanhuan
    He, Peipei
    Ran, Xiong
    Xu, Yu
    Zou, Ya
    Wu, Jingsong
    Li, Zan
    Tan, Wei
    Zhang, Zhengying
    Li, Kang
    ABDOMINAL RADIOLOGY, 2024, 49 (03) : 814 - 822
  • [5] Value of the virtual monoenergetic image from dual-layer dual-energy computed tomography enterography in the preoperative assessment of the internal penetrating complication of Crohn’s disease
    Meilin Gong
    Lili Liu
    Huanhuan Ren
    Peipei He
    Xiong Ran
    Yu Xu
    Ya Zou
    Jingsong Wu
    Zan Li
    Wei Tan
    Zhengying Zhang
    Kang Li
    Abdominal Radiology, 2024, 49 : 814 - 822
  • [6] HEART VESSELS - Acute or chronic Pulmonary Embolism: Dual-Layer Dual-Energy Computed Tomography
    Lorenz, Judith
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2024, 196 (11): : 1106 - 1107
  • [7] Strategies to Improve Image Quality on Dual-Energy Computed Tomography
    Patel, Bhavik N.
    Marin, Daniele
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2018, 56 (04) : 641 - +
  • [8] Assessment of Metal Artifact Reduction in Dual-Layer Dual-Energy Computed Tomography for Carbon Ion Radiotherapy
    Jung, S.
    Kim, B.
    Yoon, E.
    Park, J.
    Kim, J.
    Son, J.
    Choi, C.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [9] Assessment of dual-energy computed tomography derived virtual monochromatic imaging for target volume delineation of brain metastases
    Kraft, Johannes
    Lutyj, Paul
    Grabenbauer, Felix
    Stroehle, Serge-Peer
    Tamihardja, Joerg
    Razinskas, Gary
    Weick, Stefan
    Richter, Anne
    Huflage, Henner
    Wittig, Andrea
    Flentje, Michael
    Lisowski, Dominik
    RADIOTHERAPY AND ONCOLOGY, 2023, 187
  • [10] Dual-layer dual-energy computed tomography for the assessment of hypovascular hepatic metastases: impact of closing k-edge on image quality and lesion detectability
    Yasunori Nagayama
    Ayumi Iyama
    Seitaro Oda
    Narumi Taguchi
    Takeshi Nakaura
    Daisuke Utsunomiya
    Yoko Kikuchi
    Yasuyuki Yamashita
    European Radiology, 2019, 29 : 2837 - 2847