Virtual Monochromatic Image Quality from Dual-Layer Dual-Energy Computed Tomography for Detecting Brain Tumors

被引:9
|
作者
Tanoue, Shota [1 ]
Nakaura, Takeshi [1 ]
Nagayama, Yasunori [1 ]
Uetani, Hiroyuki [1 ]
Ikeda, Osamu [1 ]
Yamashita, Yasuyuki [1 ]
机构
[1] Kumamoto Univ, Grad Sch Med Sci, Dept Diagnost Radiol, Honjo 1-1-1, Kumamoto, Kumamoto 8608556, Japan
关键词
Tomography; X-ray computed; Radiography; Dual-energy scanned projection; Image enhancement; Brain neoplasms; HEAD CT; 120; KVP; RECONSTRUCTION; CONTRAST; HEMORRHAGE; VOLTAGE;
D O I
10.3348/kjr.2020.0677
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To evaluate the usefulness of virtual monochromatic images (VMIs) obtained using dual-layer dual-energy CT (DL-DECT) for evaluating brain tumors. Materials and Methods: This retrospective study included 32 patients with brain tumors who had undergone non-contrast head CT using DL-DECT. Among them, 15 had glioblastoma (GBM), 7 had malignant lymphoma, 5 had high-grade glioma other than GBM, 3 had low-grade glioma, and 2 had metastatic tumors. Conventional polychromatic images and VMIs (40-200 keV at 10 keV intervals) were generated. We compared CT attenuation, image noise, contrast, and contrast-to-noise ratio (CNR) between tumor and white matter (WM) or grey matter (GM) between VMIs showing the highest CNR (optimized VMI) and conventional CT images using the paired t test. Two radiologists subjectively assessed the contrast, margin, noise, artifact, and diagnostic confidence of optimized VMIs and conventional images on a 4-point scale. Results: The image noise of VMIs at all energy levels tested was significantly lower than that of conventional CT images (p < 0.05). The 40-keV VMIs yielded the best CNR. Furthermore, both contrast and CNR between the tumor and WM were significantly higher in the 40 keV images than in the conventional CT images (p < 0.001); however, the contrast and CNR between tumor and GM were not significantly different (p = 0.47 and p = 0.31, respectively). The subjective scores assigned to contrast, margin, and diagnostic confidence were significantly higher for 40 keV images than for conventional CT images (p < 0.01). Conclusion: In head CT for patients with brain tumors, compared with conventional CT images, 40 keV VMIs from DL-DECT yielded superior tumor contrast and diagnostic confidence, especially for brain tumors located in the WM.
引用
收藏
页码:951 / 958
页数:8
相关论文
共 50 条
  • [21] Extension and Spatial Distribution of Atherosclerotic Burden Using Virtual Monochromatic Imaging Derived From Dual-energy Computed Tomography
    Rodriguez-Granillo, Gaston A.
    Carrascosa, Patricia
    Deviggiano, Alejandro
    Capunay, Carlos
    de Zan, Macarena C.
    Goldsmit, Alejandro
    REVISTA ESPANOLA DE CARDIOLOGIA, 2016, 69 (10): : 915 - 922
  • [22] Dual-Energy Computed Tomography: Is There a Penalty in Image Quality and Radiation Dose Compared With Single-Energy Computed Tomography?
    Thomas, Christoph
    Ketelsen, Dominik
    Tsiflikas, Ilias
    Reimann, Anja
    Brodoefel, Harald
    Claussen, Claus D.
    Heuschmid, Martin
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2010, 34 (02) : 309 - 315
  • [23] Clinical Usefulness of Dual-Energy Cardiac Computed Tomography in Acute Coronary Syndrome Using a Dual-Layer Spectral Detector Scanner
    Nishihara, Taiki
    Oda, Seitaro
    Sueta, Daisuke
    Izumiya, Yasuhiro
    Kaikita, Koichi
    Tsujita, Kenichi
    Utsunomiya, Daisuke
    Nakaura, Takeshi
    Yamashita, Yasuyuki
    CIRCULATION-CARDIOVASCULAR IMAGING, 2018, 11 (02)
  • [24] Accuracy of electron density, effective atomic number, and iodine concentration determination with a dual-layer dual-energy computed tomography system
    Hua, Chia-ho
    Shapira, Nadav
    Merchant, Thomas E.
    Klahr, Paul
    Yagil, Yoad
    MEDICAL PHYSICS, 2018, 45 (06) : 2486 - 2497
  • [25] A novel image optimization method for dual-energy computed tomography
    Hao, Jia
    Kang, Kejun
    Zhang, Li
    Chen, Zhiqiang
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 722 : 34 - 42
  • [26] Usefulness of dual-energy computed tomography for oral cancer image
    Osamu Tanaka
    Makoto Matsubara
    Yuichi Ehara
    Takuya Taniguchi
    Yasunori Muramatsu
    Yasuhisa Hasegawa
    Chiyoko Makita
    Masayuki Matsuo
    Shinichiro Sumitomo
    Oral Radiology, 2021, 37 : 585 - 590
  • [27] Dual-Energy Computed Tomography Image Acquisition, Processing, and Workflow
    Megibow, Alec J.
    Kambadakone, Avinash
    Ananthakrishnan, Lakshmi
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2018, 56 (04) : 507 - +
  • [28] Usefulness of dual-energy computed tomography for oral cancer image
    Tanaka, Osamu
    Matsubara, Makoto
    Ehara, Yuichi
    Taniguchi, Takuya
    Muramatsu, Yasunori
    Hasegawa, Yasuhisa
    Makita, Chiyoko
    Matsuo, Masayuki
    Sumitomo, Shinichiro
    ORAL RADIOLOGY, 2021, 37 (04) : 585 - 590
  • [29] A Mathematical Approach to Image Reconstruction on Dual-Energy Computed Tomography
    Kim, Sungwhan
    Ahn, Chi Young
    Kang, Sung-Ho
    Ha, Taeyoung
    Jeon, Kiwan
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [30] Introduction to Dual-Energy Computed Tomography
    Elster, Allen D.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (06) : 823 - 823