An Optimized Robot-Based Technique for Cochlear Implantation to Reduce Array Insertion Trauma

被引:33
|
作者
Torres, Renato [1 ,2 ]
Jia, Huan [1 ,3 ]
Drouillard, Mylene [1 ,2 ]
Bensimon, Jean-Loup [4 ]
Sterkers, Olivier [1 ,2 ]
Ferrary, Evelyne [1 ,2 ]
Nguyen, Yann [1 ,2 ]
机构
[1] Sorbonne Univ, INSERM, Unite Rehabil Chirurg Miniinvas & Robotisee Audit, Paris, France
[2] GHU Pitie Salpetriere, AP HP, Serv ORL Otol Implants Auditifs & Chirurg Base Cr, Paris, France
[3] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 9, Sch Med, Dept Otolaryngol Head & Neck Surg, Shanghai, Peoples R China
[4] Radiol RMX, Paris, France
关键词
temporal bones; anatomy and histology; cochlea; scala tympani; scala vestibuli; cone-beam computed tomography; tomography scanners; neuronavigation; robotics; IMPACT; FORCE; TOOL; VARIABILITY; DESIGN; SPEED; AXIS;
D O I
10.1177/0194599818792232
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Objective To compare the intracochlear trauma induced by optimized robot-based and manual techniques with a straight electrode array prototype inserted at different lengths. Study Design Experimental study. Setting Robot-based otologic surgery laboratory. Subjects and Methods A prototype array was inserted at different insertion lengths (21 and 25 mm) in 20 temporal bones. The manual insertion was performed with a microforceps. The optimized approach consisted of an optimal axis insertion provided by a robot-based arm controlled by a tracking system, with a constant speed of insertion (0.25 mm/s) achieved by a motorized insertion tool. The electrode position was determined at the level of each electrode by stereomicroscopic cochlea section analysis. Results A higher number of electrodes correctly located in the scala tympani was associated with the optimized approach (P = .03, 2-way analysis of variance). Regardless of the insertion technique used, the array inserted at 25 mm allowed complete insertion of the active stimulating portion of the array in all cases. Insertion depth was greater when the array was inserted to 25 mm versus 21 mm (P < .001, 2-way analysis of variance). The optimized insertion was associated with less trauma than that from manual insertion regardless the length of the inserted array (P = .04, 2-way analysis of variance). Conclusion Compared with a manual insertion, intracochlear trauma could be reduced with array insertion performed on an optimal axis by using motorized insertion and by applying a constant insertion speed.
引用
收藏
页码:900 / 907
页数:8
相关论文
共 50 条
  • [41] Auditory outcomes after scala vestibuli array insertion are similar to those after scala tympani insertion 1 year after cochlear implantation
    Gu, Wenxi
    Daoudi, Hannah
    Lahlou, Ghizlene
    Sterkers, Olivier
    Ferrary, Evelyne
    Nguyen, Yann
    Mosnier, Isabelle
    Torres, Renato
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2024, 281 (01) : 155 - 162
  • [42] Auditory outcomes after scala vestibuli array insertion are similar to those after scala tympani insertion 1 year after cochlear implantation
    Wenxi Gu
    Hannah Daoudi
    Ghizlene Lahlou
    Olivier Sterkers
    Evelyne Ferrary
    Yann Nguyen
    Isabelle Mosnier
    Renato Torres
    European Archives of Oto-Rhino-Laryngology, 2024, 281 : 155 - 162
  • [43] Intraoperative Impedance-Based Estimation of Cochlear Implant Electrode Array Insertion Depth
    Aebischer, Philipp
    Meyer, Stefan
    Caversaccio, Marco
    Wimmer, Wilhelm
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2021, 68 (02) : 545 - 555
  • [44] Fabrication and evaluation of an improved polymer-based cochlear electrode array for atraumatic insertion
    Tae Mok Gwon
    Kyou Sik Min
    Jin Ho Kim
    Seung Ha Oh
    Ho Sun Lee
    Min-Hyun Park
    Sung June Kim
    Biomedical Microdevices, 2015, 17
  • [45] Fabrication and evaluation of an improved polymer-based cochlear electrode array for atraumatic insertion
    Gwon, Tae Mok
    Min, Kyou Sik
    Kim, Jin Ho
    Oh, Seung Ha
    Lee, Ho Sun
    Park, Min-Hyun
    Kim, Sung June
    BIOMEDICAL MICRODEVICES, 2015, 17 (02)
  • [46] A Study on Swarm Robot-Based Invader-Enclosing Technique on Multiple Distributed Object Environments
    Ko, Kwang-Eun
    Park, Seung-Min
    Park, Junheong
    Sim, Kwee-Bo
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2011, 6 (06) : 806 - 816
  • [47] Hearing preservation in children with electric-acoustic stimulation after cochlear implantation Outcome after electrode insertion with minimal insertion trauma (German version)
    Rader, T.
    Bohnert, A.
    Matthias, C.
    Koutsimpelas, D.
    Kainz, M. -A.
    Strieth, S.
    HNO, 2018, 66 (09) : 660 - 667
  • [48] An implantation technique for polyimide based flexible array probes facilitating neuronavigation and chronic implantation
    Loeffler, S.
    Xie, Y.
    Detemple, P.
    Moser, A.
    Hofmann, U. G.
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2012, 57 : 858 - 861
  • [49] Clinical experiences with intraoperative electrocochleography in cochlear implant recipients and its potential to reduce insertion trauma and improve postoperative hearing preservation
    Buechner, Andreas
    Bardt, Michael
    Haumann, Sabine
    Geissler, Gunnar
    Salcher, Rolf
    Lenarz, Thomas
    PLOS ONE, 2022, 17 (04):
  • [50] Fluoroscopy guided electrode-array insertion for cochlear implantation with straight electrode-arrays: a valuable tool in most cases
    Chiara Perazzini
    Mathilde Puechmaille
    Nicolas Saroul
    Olivier Plainfossé
    Laura Montrieul
    Justine Bécaud
    Laurent Gilain
    Pascal Chabrot
    Louis Boyer
    Thierry Mom
    European Archives of Oto-Rhino-Laryngology, 2021, 278 : 965 - 975