An Optimized Robot-Based Technique for Cochlear Implantation to Reduce Array Insertion Trauma

被引:33
|
作者
Torres, Renato [1 ,2 ]
Jia, Huan [1 ,3 ]
Drouillard, Mylene [1 ,2 ]
Bensimon, Jean-Loup [4 ]
Sterkers, Olivier [1 ,2 ]
Ferrary, Evelyne [1 ,2 ]
Nguyen, Yann [1 ,2 ]
机构
[1] Sorbonne Univ, INSERM, Unite Rehabil Chirurg Miniinvas & Robotisee Audit, Paris, France
[2] GHU Pitie Salpetriere, AP HP, Serv ORL Otol Implants Auditifs & Chirurg Base Cr, Paris, France
[3] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 9, Sch Med, Dept Otolaryngol Head & Neck Surg, Shanghai, Peoples R China
[4] Radiol RMX, Paris, France
关键词
temporal bones; anatomy and histology; cochlea; scala tympani; scala vestibuli; cone-beam computed tomography; tomography scanners; neuronavigation; robotics; IMPACT; FORCE; TOOL; VARIABILITY; DESIGN; SPEED; AXIS;
D O I
10.1177/0194599818792232
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Objective To compare the intracochlear trauma induced by optimized robot-based and manual techniques with a straight electrode array prototype inserted at different lengths. Study Design Experimental study. Setting Robot-based otologic surgery laboratory. Subjects and Methods A prototype array was inserted at different insertion lengths (21 and 25 mm) in 20 temporal bones. The manual insertion was performed with a microforceps. The optimized approach consisted of an optimal axis insertion provided by a robot-based arm controlled by a tracking system, with a constant speed of insertion (0.25 mm/s) achieved by a motorized insertion tool. The electrode position was determined at the level of each electrode by stereomicroscopic cochlea section analysis. Results A higher number of electrodes correctly located in the scala tympani was associated with the optimized approach (P = .03, 2-way analysis of variance). Regardless of the insertion technique used, the array inserted at 25 mm allowed complete insertion of the active stimulating portion of the array in all cases. Insertion depth was greater when the array was inserted to 25 mm versus 21 mm (P < .001, 2-way analysis of variance). The optimized insertion was associated with less trauma than that from manual insertion regardless the length of the inserted array (P = .04, 2-way analysis of variance). Conclusion Compared with a manual insertion, intracochlear trauma could be reduced with array insertion performed on an optimal axis by using motorized insertion and by applying a constant insertion speed.
引用
收藏
页码:900 / 907
页数:8
相关论文
共 50 条
  • [21] Cochlear implantation via the round window membrane minimizes trauma to cochlear structures: A histologically controlled insertion study
    Adunka, O
    Unkelbach, MH
    Mack, M
    Hambek, M
    Gstoettner, W
    Kiefer, J
    ACTA OTO-LARYNGOLOGICA, 2004, 124 (07) : 807 - 812
  • [22] Prolonged Insertion Time Reduces Translocation Rate of a Precurved Electrode Array in Cochlear Implantation
    van der Jagt, Annerie M. A.
    Briaire, Jeroen J.
    Boehringer, Stefan
    Verbist, Berit M.
    Frijns, Johan H. M.
    OTOLOGY & NEUROTOLOGY, 2022, 43 (04) : E427 - E434
  • [23] Automated and Cycle Time Optimized Path Planning for Robot-Based Inspection Systems
    Ulrich, Marco
    Lux, Gregor
    Juergensen, Leila
    Reinhart, Gunther
    6TH CIRP CONFERENCE ON ASSEMBLY TECHNOLOGIES AND SYSTEMS (CATS), 2016, 44 : 377 - 382
  • [24] Insertion Guidance Based on Impedance Measurements of a Cochlear Electrode Array
    Salkim, Enver
    Zamani, Majid
    Jiang, Dai
    Saeed, Shakeel R.
    Demosthenous, Andreas
    FRONTIERS IN COMPUTATIONAL NEUROSCIENCE, 2022, 16
  • [25] Evaluation of Insertion Forces and Cochlea Trauma Following Robotics-Assisted Cochlear Implant Electrode Array Insertion
    Kaufmann, Christopher R.
    Henslee, Allan M.
    Claussen, Alex
    Hansen, Marlan R.
    OTOLOGY & NEUROTOLOGY, 2020, 41 (05) : 631 - 638
  • [26] Insertion trauma and recovery of function after cochlear implantation: Evidence from objective functional measures
    Pfingst, Bryan E.
    Hughes, Aaron P.
    Colesa, Deborah J.
    Watts, Melissa M.
    Strahl, Stefan B.
    Raphael, Yehoash
    HEARING RESEARCH, 2015, 330 : 98 - 105
  • [27] Rounded insertion technique for cochlear implantation surgery to treat cystic inner ear malformation
    Hu, Hao-Chun
    Chen, William Kuan-Hua
    Huang, Mei-Jui
    Lin, Chi-Ching
    Chen, Joshua Kuang-Chao
    LARYNGOSCOPE, 2020, 130 (09): : 2229 - 2233
  • [28] Robotic assistance during cochlear implantation: the rationale for consistent, controlled speed of electrode array insertion
    Kashani, Rustin G.
    Henslee, Allan
    Nelson, Rick F.
    Hansen, Marlan R.
    FRONTIERS IN NEUROLOGY, 2024, 15
  • [29] Insertion of Cochlear Implant Electrode Array Using the Underwater Technique for Preserving Residual Hearing
    Anagiotos, Andreas
    Beutner, Dirk
    Gostian, Antoniu-Oreste
    Schwarz, David
    Luers, Jan-Christoffer
    Huettenbrink, Karl-Bernd
    OTOLOGY & NEUROTOLOGY, 2016, 37 (04) : 339 - 344
  • [30] Exploring Trauma Patterns and Contributing Factors With Slim Straight Electrode Array After Cochlear Implantation
    Torres, Renato
    Daoudi, Hannah
    Gu, Wenxi
    Breil, Eugenie
    Ferrary, Evelyne
    Sterkers, Olivier
    Nguyen, Yann
    Mosnier, Isabelle
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2024, 171 (02) : 521 - 529