An Optimized Robot-Based Technique for Cochlear Implantation to Reduce Array Insertion Trauma

被引:33
|
作者
Torres, Renato [1 ,2 ]
Jia, Huan [1 ,3 ]
Drouillard, Mylene [1 ,2 ]
Bensimon, Jean-Loup [4 ]
Sterkers, Olivier [1 ,2 ]
Ferrary, Evelyne [1 ,2 ]
Nguyen, Yann [1 ,2 ]
机构
[1] Sorbonne Univ, INSERM, Unite Rehabil Chirurg Miniinvas & Robotisee Audit, Paris, France
[2] GHU Pitie Salpetriere, AP HP, Serv ORL Otol Implants Auditifs & Chirurg Base Cr, Paris, France
[3] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 9, Sch Med, Dept Otolaryngol Head & Neck Surg, Shanghai, Peoples R China
[4] Radiol RMX, Paris, France
关键词
temporal bones; anatomy and histology; cochlea; scala tympani; scala vestibuli; cone-beam computed tomography; tomography scanners; neuronavigation; robotics; IMPACT; FORCE; TOOL; VARIABILITY; DESIGN; SPEED; AXIS;
D O I
10.1177/0194599818792232
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Objective To compare the intracochlear trauma induced by optimized robot-based and manual techniques with a straight electrode array prototype inserted at different lengths. Study Design Experimental study. Setting Robot-based otologic surgery laboratory. Subjects and Methods A prototype array was inserted at different insertion lengths (21 and 25 mm) in 20 temporal bones. The manual insertion was performed with a microforceps. The optimized approach consisted of an optimal axis insertion provided by a robot-based arm controlled by a tracking system, with a constant speed of insertion (0.25 mm/s) achieved by a motorized insertion tool. The electrode position was determined at the level of each electrode by stereomicroscopic cochlea section analysis. Results A higher number of electrodes correctly located in the scala tympani was associated with the optimized approach (P = .03, 2-way analysis of variance). Regardless of the insertion technique used, the array inserted at 25 mm allowed complete insertion of the active stimulating portion of the array in all cases. Insertion depth was greater when the array was inserted to 25 mm versus 21 mm (P < .001, 2-way analysis of variance). The optimized insertion was associated with less trauma than that from manual insertion regardless the length of the inserted array (P = .04, 2-way analysis of variance). Conclusion Compared with a manual insertion, intracochlear trauma could be reduced with array insertion performed on an optimal axis by using motorized insertion and by applying a constant insertion speed.
引用
收藏
页码:900 / 907
页数:8
相关论文
共 50 条
  • [31] Multi-Frequency Electrocochleography and Electrode Scan to Identify Electrode Insertion Trauma during Cochlear Implantation
    Saoji, Aniket A.
    Graham, Madison K.
    Adkins, Weston J.
    Koka, Kanthaiah
    Carlson, Matthew L.
    Neff, Brian A.
    Driscoll, Colin L. W.
    Fitzpatrick, Douglas C.
    BRAIN SCIENCES, 2023, 13 (02)
  • [32] Three-Dimensional Force Profile During Cochlear Implantation Depends on Individual Geometry and Insertion Trauma
    Avci, Ersin
    Nauwelaers, Tim
    Hamacher, Volkmar
    Kral, Andrej
    EAR AND HEARING, 2017, 38 (03): : E168 - E179
  • [33] Robot-Assisted Electrode Insertion in Cochlear Implantation Controlled by Intraoperative Electrocochleography-A Pilot Study
    Gawecki, Wojciech
    Balcerowiak, Andrzej
    Podlawska, Paulina
    Borowska, Patrycja
    Gibasiewicz, Renata
    Szyfter, Witold
    Wierzbicka, Malgorzata
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (23)
  • [34] Association between lateral wall electrode array insertion parameters and audiological outcomes in bilateral cochlear implantation
    Vivian Thimsen
    Konstantinos Mantsopoulos
    Tim Liebscher
    Lava Taha
    Felix Eisenhut
    Heinrich Iro
    Ulrich Hoppe
    Joachim Hornung
    European Archives of Oto-Rhino-Laryngology, 2023, 280 : 2707 - 2714
  • [35] Insertion site and sealing technique affect residual hearing and tissue formation after cochlear implantation
    Burghard, Alice
    Lenarz, Thomas
    Kral, Andrej
    Paasche, Gerrit
    HEARING RESEARCH, 2014, 312 : 21 - 27
  • [36] Association between lateral wall electrode array insertion parameters and audiological outcomes in bilateral cochlear implantation
    Thimsen, Vivian
    Mantsopoulos, Konstantinos
    Liebscher, Tim
    Taha, Lava
    Eisenhut, Felix
    Iro, Heinrich
    Hoppe, Ulrich
    Hornung, Joachim
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2023, 280 (06) : 2707 - 2714
  • [37] Robot-assisted vs. manual cochlear implant electrode array insertion in four children
    Sykopetrites, Vittoria
    Sica, Eleonora
    Moalli, Raffaella
    Cocozza, Davide
    Razza, Sergio
    Cristofari, Eliana
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2025,
  • [38] Evaluating cochlear insertion trauma and hearing preservation after cochlear implantation (CIPRES): a study protocol for a randomized single-blind controlled trial
    Jwair, Saad
    Boerboom, Ralf A.
    Versnel, Huib
    Stokroos, Robert J.
    Thomeer, Hans G. X. M.
    TRIALS, 2021, 22 (01)
  • [39] Evaluating cochlear insertion trauma and hearing preservation after cochlear implantation (CIPRES): a study protocol for a randomized single-blind controlled trial
    Saad Jwair
    Ralf A. Boerboom
    Huib Versnel
    Robert J. Stokroos
    Hans G. X. M. Thomeer
    Trials, 22
  • [40] Cone Beam and Micro-Computed Tomography Validation of Manual Array Insertion for Minimally Invasive Cochlear Implantation
    Wimmer, Wilhelm
    Bell, Brett
    Huth, Markus E.
    Weisstanner, Christian
    Gerber, Nicolas
    Kompis, Martin
    Weber, Stefan
    Caversaccio, Marco
    AUDIOLOGY AND NEURO-OTOLOGY, 2014, 19 (01) : 22 - 30