An Optimized Robot-Based Technique for Cochlear Implantation to Reduce Array Insertion Trauma

被引:33
|
作者
Torres, Renato [1 ,2 ]
Jia, Huan [1 ,3 ]
Drouillard, Mylene [1 ,2 ]
Bensimon, Jean-Loup [4 ]
Sterkers, Olivier [1 ,2 ]
Ferrary, Evelyne [1 ,2 ]
Nguyen, Yann [1 ,2 ]
机构
[1] Sorbonne Univ, INSERM, Unite Rehabil Chirurg Miniinvas & Robotisee Audit, Paris, France
[2] GHU Pitie Salpetriere, AP HP, Serv ORL Otol Implants Auditifs & Chirurg Base Cr, Paris, France
[3] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 9, Sch Med, Dept Otolaryngol Head & Neck Surg, Shanghai, Peoples R China
[4] Radiol RMX, Paris, France
关键词
temporal bones; anatomy and histology; cochlea; scala tympani; scala vestibuli; cone-beam computed tomography; tomography scanners; neuronavigation; robotics; IMPACT; FORCE; TOOL; VARIABILITY; DESIGN; SPEED; AXIS;
D O I
10.1177/0194599818792232
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Objective To compare the intracochlear trauma induced by optimized robot-based and manual techniques with a straight electrode array prototype inserted at different lengths. Study Design Experimental study. Setting Robot-based otologic surgery laboratory. Subjects and Methods A prototype array was inserted at different insertion lengths (21 and 25 mm) in 20 temporal bones. The manual insertion was performed with a microforceps. The optimized approach consisted of an optimal axis insertion provided by a robot-based arm controlled by a tracking system, with a constant speed of insertion (0.25 mm/s) achieved by a motorized insertion tool. The electrode position was determined at the level of each electrode by stereomicroscopic cochlea section analysis. Results A higher number of electrodes correctly located in the scala tympani was associated with the optimized approach (P = .03, 2-way analysis of variance). Regardless of the insertion technique used, the array inserted at 25 mm allowed complete insertion of the active stimulating portion of the array in all cases. Insertion depth was greater when the array was inserted to 25 mm versus 21 mm (P < .001, 2-way analysis of variance). The optimized insertion was associated with less trauma than that from manual insertion regardless the length of the inserted array (P = .04, 2-way analysis of variance). Conclusion Compared with a manual insertion, intracochlear trauma could be reduced with array insertion performed on an optimal axis by using motorized insertion and by applying a constant insertion speed.
引用
收藏
页码:900 / 907
页数:8
相关论文
共 50 条
  • [1] Improvement of the insertion axis for cochlear implantation with a robot-based system
    Torres, Renato
    Kazmitcheff, Guillaume
    De Seta, Daniele
    Ferrary, Evelyne
    Sterkers, Olivier
    Nguyen, Yann
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2017, 274 (02) : 715 - 721
  • [2] Improvement of the insertion axis for cochlear implantation with a robot-based system
    Renato Torres
    Guillaume Kazmitcheff
    Daniele De Seta
    Evelyne Ferrary
    Olivier Sterkers
    Yann Nguyen
    European Archives of Oto-Rhino-Laryngology, 2017, 274 : 715 - 721
  • [3] ELECTRODE INSERTION TRAUMA IN COCHLEAR IMPLANTATION
    OLEARY, MJ
    HOUSE, WF
    FAYAD, J
    LINTHICUM, FH
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1991, 100 (09): : 695 - 699
  • [4] Are tinnitus burden and tinnitus exacerbation after cochlear implantation influenced by insertion technique, array dislocation, and intracochlear trauma?
    Everad, F.
    Beck, R. L.
    Aschendorff, A.
    Rauch, A. K.
    Fries, Leonie
    Arndt, S.
    Ketterer, M. C.
    FRONTIERS IN NEUROLOGY, 2024, 15
  • [5] Insertion of electrode array using percutaneous cochlear implantation technique: a cadaveric study
    Balachandran, Ramya
    Mitchell, Jason E.
    Noble, Jack
    Schurzig, Daniel
    Blachon, Gregoire
    McRackan, Theodore R.
    Webster, Robert J.
    Dawant, Benoit M.
    Fitzpatrick, J. Michael
    Labadie, Robert F.
    MEDICAL IMAGING 2011: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2011, 7964
  • [6] Robot-based assistance in middle ear surgery and cochlear implantation: first clinical report
    Sykopetrites Vittoria
    Ghizlene Lahlou
    Renato Torres
    Hannah Daoudi
    Isabelle Mosnier
    Stéphane Mazalaigue
    Evelyne Ferrary
    Yann Nguyen
    Olivier Sterkers
    European Archives of Oto-Rhino-Laryngology, 2021, 278 : 77 - 85
  • [7] Robot-based assistance in middle ear surgery and cochlear implantation: first clinical report
    Vittoria, Sykopetrites
    Lahlou, Ghizlene
    Torres, Renato
    Daoudi, Hannah
    Mosnier, Isabelle
    Mazalaigue, Stephane
    Ferrary, Evelyne
    Yann Nguyen
    Sterkers, Olivier
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2021, 278 (01) : 77 - 85
  • [8] Automated robot-based screw insertion system
    Lara, B
    Althoefer, K
    Seneviratne, LD
    IECON '98 - PROCEEDINGS OF THE 24TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1-4, 1998, : 2440 - 2445
  • [9] Insertion trauma of a cochlear implant electrode array with Nitinol inlay
    Rau, Thomas S.
    Harbach, Lenka
    Pawsey, Nick
    Kluge, Marcel
    Erfurt, Peter
    Lenarz, Thomas
    Majdani, Omid
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2016, 273 (11) : 3573 - 3585
  • [10] Insertion trauma of a cochlear implant electrode array with Nitinol inlay
    Thomas S. Rau
    Lenka Harbach
    Nick Pawsey
    Marcel Kluge
    Peter Erfurt
    Thomas Lenarz
    Omid Majdani
    European Archives of Oto-Rhino-Laryngology, 2016, 273 : 3573 - 3585