Linshom respiratory monitoring device: a novel temperature-based respiratory monitor

被引:1
|
作者
Lerman, Jerrold [1 ,2 ]
Feldman, Doron [2 ]
Feldman, Ronen [3 ]
Moser, John [3 ]
Feldman, Leeshi [4 ]
Sathyamoorthy, Madhankumar [5 ]
Deitch, Kenneth [6 ]
Feldman, Uri [3 ]
机构
[1] Women & Childrens Hosp Buffalo, Dept Anesthesia, 219 Bryant St, Buffalo, NY 14209 USA
[2] SUNY Buffalo, Buffalo, NY USA
[3] Artep Inc, Ellicott City, MD USA
[4] Sackler Sch Med, Tel Aviv, Israel
[5] Univ Mississippi, Med Ctr, Dept Anesthesiol, Jackson, MS 39216 USA
[6] Thomas Jefferson Univ, Einstein Med Ctr, Dept Emergency Med, Philadelphia, PA 19107 USA
关键词
PULSE OXIMETRY; ACCURACY; APNEA; CAPNOGRAPHY; IMPEDANCE;
D O I
10.1007/s12630-016-0694-y
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
We sought to develop a temperature-based respiratory instrument to measure respiration noninvasively outside critical care settings. Respiratory temperature profiles were recorded using a temperature-based noninvasive instrument comprised of three rapid responding medical-grade thermistors-two in close proximity to the mouth/nose (sensors) and one remote to the airway (reference). The effect of the gas flow rate on the amplitude of the tracings was determined. The temperature-based instrument, the Linshom Respiratory Monitoring Device (LRMD) was mounted to a face mask and positioned on a mannequin face. Respiratory rates of 5-40 breaths center dot min(-1) were then delivered to the mannequin face in random order using artificial bellows (IngMar Lung Model). Data from the sensors were collected and compared with the bellows rates using least squares linear regression and coefficient of determination. The investigators breathed at fixed rates of 0-60 breaths center dot min(-1) in synchrony with a metronome as their respiratory temperature profiles were recorded from sensors mounted to either a face mask or nasal prongs. The recordings were compared with a contemporaneously recorded sidestream capnogram from a CARESCAPE GEB450 Monitor. The extracted respiratory rates from the LRMD tracings and capnograms were compared using linear regression with a coefficient of determination and a Bland-Altman plot. The amplitude of the sensor tracings was independent of the oxygen flow rate. Respiratory rates from the new temperature-based sensor were synchronous and correlated identically with both the artificial bellows (r(2) = 0.9997) and the capnometer mounted to both the face mask and nasal prongs (r(2) = 0.99; bias = -0.17; 95% confidence interval, -2.15 to 1.8). Respiratory rates using the LRMD, a novel temperature-based respiratory instrument, were consistent with those using capnometry.
引用
收藏
页码:1154 / 1160
页数:7
相关论文
共 50 条
  • [31] Evaluation of a new fibre-optical monitor for respiratory rate monitoring
    Larsson, C
    Staun, P
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1999, 15 (05) : 295 - 298
  • [32] Continuous respiratory monitoring for sleep apnea screening by ambulatory hemodynamic monitor
    Dillier, Roger
    Baumann, Markus
    Young, Mabelle
    Erne, Susanne
    Schwizer, Bernhard
    Zuber, Michel
    Erne, Paul
    WORLD JOURNAL OF CARDIOLOGY, 2012, 4 (04): : 121 - 127
  • [33] A new type of temperature-based sensor for monitoring of bridge scour
    Ding, Yong
    Yan, Tengteng
    Yao, Qingxiong
    Dong, Xuehua
    Wang, Xin
    MEASUREMENT, 2016, 78 : 245 - 252
  • [34] Evaluation of a New Fibre-Optical Monitor for Respiratory Rate Monitoring
    Caisa Larsson
    Philip Staun
    Journal of Clinical Monitoring and Computing, 1999, 15 : 295 - 298
  • [35] Optimal Temperature-Based Condition Monitoring System for Wind Turbines
    Baboli, Payam Teimourzadeh
    Babazadeh, Davood
    Raeiszadeh, Amin
    Horodyvskyy, Susanne
    Koprek, Isabel
    INFRASTRUCTURES, 2021, 6 (04)
  • [36] Respiratory Function Monitor Based on Surface Diaphragm Electromyography
    Song, X.
    Li, Y. C.
    Zhang, W. G.
    Yan, S. P.
    Li, Y. Q.
    12TH ASIAN-PACIFIC CONFERENCE ON MEDICAL AND BIOLOGICAL ENGINEERING, VOL 1, APCMBE 2023, 2024, 103 : 18 - 28
  • [37] Elements of Vision Based Respiratory Monitoring
    Eastwood-Sutherland, Caillin
    Gale, Timothy J.
    Dargaville, Peter A.
    Wheeler, Kevin
    2015 8TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON), 2015,
  • [38] Validation of a novel wearable monitoring patch for continuous respiratory monitoring
    John, M.
    Van der Westen, R. Garcia
    Yordanova, G.
    Groenendaal, W.
    Agell, C.
    John, M.
    EUROPEAN RESPIRATORY JOURNAL, 2022, 60
  • [39] RESPIRATORY MONITOR FOR RESERVOIR BAG - DEVICE FOR USE IN DARKENED OPERATING-THEATERS
    WILLIAMS, TM
    ANAESTHESIA, 1974, 29 (05) : 603 - 604
  • [40] Validation study of the AirGo™ device for continuous monitoring of respiratory function
    Antonelli, Andrea
    Stanzi, Alessia
    Mazza, Federico
    Venturino, Massimiliano
    Noceti, Paolo
    Guilizzoni, Dario
    Aliverti, Andrea
    Melloni, Giulio
    EUROPEAN RESPIRATORY JOURNAL, 2018, 52