Respiratory Function Monitor Based on Surface Diaphragm Electromyography

被引:0
|
作者
Song, X. [1 ]
Li, Y. C. [1 ]
Zhang, W. G. [1 ]
Yan, S. P. [1 ]
Li, Y. Q. [1 ]
机构
[1] Army Med Univ, Dept Biomed Engn & Imaging Med, Chongqing, Peoples R China
关键词
Surface diaphragm electromyography; Electrocardiography; Bio-impedance; Respiratory function monitoring;
D O I
10.1007/978-3-031-51455-5_3
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
To design a respiratory function monitoring system with surface diaphragm electromyography that can be used to monitor respiratory function in the home or with medical agents. Based on the STM32F411VET6 microcontroller system, two electrodes were used to detect the surface EMG signals. Additional two circular disposable Ag/AgCl electrodes were applied for the output of high-frequency excitation and the input of ECG and bio-impedance signals. The hardware system included a diaphragm EMG detection circuit, ECG detection circuit, bio-impedance detection circuit, constant current source excitation circuit, and microcontroller. The analog signals were digitalized by theA/D mode of theMCU, and the digitalized signals were stored in a secure digitalmemory card through the secure digital input and output protocol. After the system design, the system was validated by acquiring signals from 10 patients with mechanical ventilation due to respiratory dysfunction and 10 healthy adults. Fifteen respiratory function-related parameters were calculated and compared between groups. The signal-to-noise ratio of the signal collected by the system was > 10 dB, the common mode rejection ratio was > 80 dB. Compared with healthy adults, inhalation time, exhalation time, tidal volume, peak-to-peak value of the bio-impedance signal, variation of bio-impedance signal in one second, diaphragmatic EMG low-band power (LF, 20-40 Hz), diaphragmatic EMG high-band power (HF, 150-250 Hz), the ratio between high-band power and low-band power., diaphragmatic electromyography area, diaphragmatic electromyography peak-to-peak, and cardiopulmonary coupling coefficient were significantly lower (P < 0.05), but heart rate was significantly higher in mechanically ventilated patients (P < 0.05). In addition, there were no significant differences in respiratory rate, diaphragmatic electromyography time, and inhalation and exhalation ratio between the two groups. The designed respiratory function monitoring system was demonstrated to be reliable. It can be used for continuously and non-invasively monitoring respiratory function in real time.
引用
收藏
页码:18 / 28
页数:11
相关论文
共 50 条
  • [1] Correlation of surface respiratory electromyography with esophageal diaphragm electromyography
    Lin, Lin
    Guan, Lili
    Wu, Weiliang
    Chen, Rongchang
    RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY, 2019, 259 : 45 - 52
  • [2] Transcutaneous electromyography of the diaphragm: A cardio-respiratory monitor for preterm infants
    Kraaijenga, Juliette V.
    Hutten, Gerard J.
    de Jongh, Frans H.
    van Kaam, Anton H.
    PEDIATRIC PULMONOLOGY, 2015, 50 (09) : 889 - 895
  • [3] Diaphragm electromyography to estimate respiratory effort: a preliminary study
    Vandenbussche, N.
    Xu, H.
    Xu, L.
    Ciccarelli, C.
    Long, X.
    Overeem, S.
    van Dijk, J. P.
    Mischi, M.
    Peri, E.
    JOURNAL OF SLEEP RESEARCH, 2020, 29 : 292 - 292
  • [4] Influence of Parameter Selection in Fixed Sample Entropy of Surface Diaphragm Electromyography for Estimating Respiratory Activity
    Estrada, Luis
    Torres, Abel
    Sarlabous, Leonardo
    Jane, Raimon
    ENTROPY, 2017, 19 (09)
  • [5] A muscle fatigue monitor based on the surface electromyography signals and frequency analysis
    Gutierrez, S. J.
    Cardiel, E.
    Hernandez, P. R.
    2016 GLOBAL MEDICAL ENGINEERING PHYSICS EXCHANGES/PAN AMERICAN HEALTH CARE EXCHANGES (GMEPE/PAHCE), 2016,
  • [6] AN INVITRO ELECTROMYOGRAPHY CHAMBER TO MONITOR NEUROMUSCULAR FUNCTION
    PAGALA, MKD
    JOURNAL OF ELECTROPHYSIOLOGICAL TECHNIQUES, 1987, 14 (04): : 197 - 209
  • [7] ELECTROMYOGRAPHY OF THE DIAPHRAGM
    FINK, BR
    NGAI, SH
    ANESTHESIOLOGY, 1959, 20 (01) : 124 - 124
  • [8] Prediction of infant extubation using surface diaphragm electromyography
    Hunt, Katie
    Hunt, Ian
    Dassios, Theodore
    Ali, Kamal
    Greenough, Anne
    EUROPEAN RESPIRATORY JOURNAL, 2019, 54
  • [9] Transesophageal Versus Surface Electromyography of the Diaphragm in Ventilated Subjects
    Lokin, Joost L. C.
    Dulger, Soray
    Glas, Gerie J.
    Horn, Janneke
    RESPIRATORY CARE, 2020, 65 (09) : 1309 - 1314
  • [10] Assessment of Inspiratory Muscle Activation using Surface Diaphragm Mechanomyography and Crural Diaphragm Electromyography
    Lozano-Garcia, Manuel
    Sarlabous, Leonardo
    Moxham, John
    Rafferty, Gerrard F.
    Torres, Abel
    Jolley, Caroline J.
    Jane, Raimon
    2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 3342 - 3345