Respiratory Function Monitor Based on Surface Diaphragm Electromyography

被引:0
|
作者
Song, X. [1 ]
Li, Y. C. [1 ]
Zhang, W. G. [1 ]
Yan, S. P. [1 ]
Li, Y. Q. [1 ]
机构
[1] Army Med Univ, Dept Biomed Engn & Imaging Med, Chongqing, Peoples R China
关键词
Surface diaphragm electromyography; Electrocardiography; Bio-impedance; Respiratory function monitoring;
D O I
10.1007/978-3-031-51455-5_3
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
To design a respiratory function monitoring system with surface diaphragm electromyography that can be used to monitor respiratory function in the home or with medical agents. Based on the STM32F411VET6 microcontroller system, two electrodes were used to detect the surface EMG signals. Additional two circular disposable Ag/AgCl electrodes were applied for the output of high-frequency excitation and the input of ECG and bio-impedance signals. The hardware system included a diaphragm EMG detection circuit, ECG detection circuit, bio-impedance detection circuit, constant current source excitation circuit, and microcontroller. The analog signals were digitalized by theA/D mode of theMCU, and the digitalized signals were stored in a secure digitalmemory card through the secure digital input and output protocol. After the system design, the system was validated by acquiring signals from 10 patients with mechanical ventilation due to respiratory dysfunction and 10 healthy adults. Fifteen respiratory function-related parameters were calculated and compared between groups. The signal-to-noise ratio of the signal collected by the system was > 10 dB, the common mode rejection ratio was > 80 dB. Compared with healthy adults, inhalation time, exhalation time, tidal volume, peak-to-peak value of the bio-impedance signal, variation of bio-impedance signal in one second, diaphragmatic EMG low-band power (LF, 20-40 Hz), diaphragmatic EMG high-band power (HF, 150-250 Hz), the ratio between high-band power and low-band power., diaphragmatic electromyography area, diaphragmatic electromyography peak-to-peak, and cardiopulmonary coupling coefficient were significantly lower (P < 0.05), but heart rate was significantly higher in mechanically ventilated patients (P < 0.05). In addition, there were no significant differences in respiratory rate, diaphragmatic electromyography time, and inhalation and exhalation ratio between the two groups. The designed respiratory function monitoring system was demonstrated to be reliable. It can be used for continuously and non-invasively monitoring respiratory function in real time.
引用
收藏
页码:18 / 28
页数:11
相关论文
共 50 条
  • [41] Neural Respiratory Drive Measured Using Surface Electromyography of Diaphragm as a Physiological Biomarker to Predict Hospitalization of Acute Exacerbation of Chronic Obstructive Pulmonary Disease Patients
    Zhang, Dan-Dan
    Lu, Gan
    Zhu, Xuan-Feng
    Zhang, Ling-Ling
    Gao, Jia
    Shi, Li-Cheng
    Gu, Jian-Hua
    Liu, Jian-Nan
    CHINESE MEDICAL JOURNAL, 2018, 131 (23) : 2800 - 2807
  • [42] The Reflection of Plication Surgery for Diaphragm Eventration to Respiratory Function Test
    Ozkan, Serdar
    Yazici, Ulku
    Aydin, Ertan
    Karaoglanoglu, Nurettin
    BALKAN MEDICAL JOURNAL, 2015, 32 (02) : 237 - 238
  • [43] Ultrasonographic modeling of diaphragm function: A novel approach to respiratory assessment
    O'Hara, Danielle N.
    Pavlov, Andrey
    Taub, Erin
    Ahmad, Sahar
    PLOS ONE, 2020, 15 (03):
  • [44] RELATIONSHIP OF DIAPHRAGM GLYCOGEN, LACTATE, AND FUNCTION TO RESPIRATORY-FAILURE
    FERGUSON, GT
    IRVIN, CG
    CHERNIACK, RM
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1990, 141 (04): : 926 - 932
  • [45] Reliability of respiratory function monitor interpretation for neonatal resuscitation
    Foglia, Elizabeth E.
    Weinberg, Danielle D.
    te Pas, Arjan B.
    Dekker, Janneke
    Hsu, Jesse Y.
    ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2022,
  • [46] Diaphragm ultrasound in spondyloarthritis: assessment of diaphragmatic motion and respiratory function
    Ajili, I. Mejri Ep
    Dghaies, A.
    Dhahri, R.
    Mhamdi, S.
    Daboussi, S.
    Aichaouia, C.
    Gharsallah, I.
    Ayed, K.
    Moatemri, Z.
    EUROPEAN RESPIRATORY JOURNAL, 2022, 60
  • [47] Neural Respiratory Drive Measured Using Surface Electromyography of Diaphragm as a Physiological Biomarker to Predict Hospitalization of Acute Exacerbation of Chronic Obstructive Pulmonary Disease Patients
    Zhang Dan-Dan
    Lu Gan
    Zhu Xuan-Feng
    Zhang Ling-Ling
    Gao Jia
    Shi Li-Cheng
    Gu Jian-Hua
    Liu Jian-Nan
    中华医学杂志英文版, 2018, 131 (23) : 2800 - 2807
  • [48] Classifying Apnea of Prematurity by Transcutaneous Electromyography of the Diaphragm
    Kraaijenga, Juliette V.
    Hutten, Gerard J.
    de Waal, Cornelia G.
    de Jongh, Frans H.
    Onland, Wes
    van Kaam, Anton H.
    NEONATOLOGY, 2018, 113 (02) : 140 - 145
  • [49] Acquisition and Semi-Automated Analysis of Respiratory Muscle Surface Electromyography
    Rodrigues, Antenor
    Janssens, Luc
    Langer, Daniel
    Matsumura, Umi
    Rozenberg, Dmitry
    Brochard, Laurent
    Reid, W. Darlene
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2025, (215):
  • [50] Surface Electromyography based finger flexion recognition
    Vijayan, Aravind E.
    John, Arlene
    Sudheer, A. P.
    2015 IEEE INTERNATIONAL CONFERENCE ON COMPUTATIONAL INTELLIGENCE AND COMMUNICATION TECHNOLOGY CICT 2015, 2015, : 592 - 596