Linshom respiratory monitoring device: a novel temperature-based respiratory monitor

被引:1
|
作者
Lerman, Jerrold [1 ,2 ]
Feldman, Doron [2 ]
Feldman, Ronen [3 ]
Moser, John [3 ]
Feldman, Leeshi [4 ]
Sathyamoorthy, Madhankumar [5 ]
Deitch, Kenneth [6 ]
Feldman, Uri [3 ]
机构
[1] Women & Childrens Hosp Buffalo, Dept Anesthesia, 219 Bryant St, Buffalo, NY 14209 USA
[2] SUNY Buffalo, Buffalo, NY USA
[3] Artep Inc, Ellicott City, MD USA
[4] Sackler Sch Med, Tel Aviv, Israel
[5] Univ Mississippi, Med Ctr, Dept Anesthesiol, Jackson, MS 39216 USA
[6] Thomas Jefferson Univ, Einstein Med Ctr, Dept Emergency Med, Philadelphia, PA 19107 USA
关键词
PULSE OXIMETRY; ACCURACY; APNEA; CAPNOGRAPHY; IMPEDANCE;
D O I
10.1007/s12630-016-0694-y
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
We sought to develop a temperature-based respiratory instrument to measure respiration noninvasively outside critical care settings. Respiratory temperature profiles were recorded using a temperature-based noninvasive instrument comprised of three rapid responding medical-grade thermistors-two in close proximity to the mouth/nose (sensors) and one remote to the airway (reference). The effect of the gas flow rate on the amplitude of the tracings was determined. The temperature-based instrument, the Linshom Respiratory Monitoring Device (LRMD) was mounted to a face mask and positioned on a mannequin face. Respiratory rates of 5-40 breaths center dot min(-1) were then delivered to the mannequin face in random order using artificial bellows (IngMar Lung Model). Data from the sensors were collected and compared with the bellows rates using least squares linear regression and coefficient of determination. The investigators breathed at fixed rates of 0-60 breaths center dot min(-1) in synchrony with a metronome as their respiratory temperature profiles were recorded from sensors mounted to either a face mask or nasal prongs. The recordings were compared with a contemporaneously recorded sidestream capnogram from a CARESCAPE GEB450 Monitor. The extracted respiratory rates from the LRMD tracings and capnograms were compared using linear regression with a coefficient of determination and a Bland-Altman plot. The amplitude of the sensor tracings was independent of the oxygen flow rate. Respiratory rates from the new temperature-based sensor were synchronous and correlated identically with both the artificial bellows (r(2) = 0.9997) and the capnometer mounted to both the face mask and nasal prongs (r(2) = 0.99; bias = -0.17; 95% confidence interval, -2.15 to 1.8). Respiratory rates using the LRMD, a novel temperature-based respiratory instrument, were consistent with those using capnometry.
引用
收藏
页码:1154 / 1160
页数:7
相关论文
共 50 条
  • [41] Validation of a Wearable Device and an Algorithm for Respiratory Monitoring During Exercise
    Massaroni, Carlo
    Nicolo, Andrea
    Girardi, Michele
    La Camera, Angelica
    Schena, Emiliano
    Sacchetti, Massimo
    Silvestri, Sergio
    Taffoni, Fabrizio
    IEEE SENSORS JOURNAL, 2019, 19 (12) : 4652 - 4659
  • [42] Monitoring respiratory impedance by wearable sensor device: Protocol and methodology
    Ionescu, Clara M.
    Copot, D.
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2017, 36 : 57 - 62
  • [43] VALIDITY OF RESPIRATORY EVENTS COLLECTED FROM A PORTABLE MONITORING DEVICE
    Bajwa, I
    Grover, S.
    Clawson, T.
    Cady, M.
    SLEEP, 2009, 32 : A376 - A376
  • [44] Continuous Respiratory Monitoring Device for Detection of Sleep Apnea Episodes
    Rotariu, Cristian
    Cristea, Ciprian
    Arotaritei, Dragos
    Bozomitu, Radu G.
    Pasarica, Alexandru
    2016 IEEE 22ND INTERNATIONAL SYMPOSIUM FOR DESIGN AND TECHNOLOGY AND ELECTRONIC PACKAGING (SIITME), 2016, : 106 - 109
  • [45] Clinical Validation of a Wearable Respiratory Rate Device for Neonatal Monitoring
    Raj, Antony A.
    Preejith, S. P.
    Raja, Vijai Shankar
    Joseph, Jayaraj
    Sivaprakasam, Mohanasankar
    2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 1628 - 1631
  • [46] Design and Evaluation of a Novel Venturi-Based Spirometer for Home Respiratory Monitoring
    Ferreira Nunes, Mariana
    Placido da Silva, Hugo
    Raposo, Liliana
    Rodrigues, Fatima
    SENSORS, 2024, 24 (17)
  • [47] Validation of a novel contact-free heart and respiratory rate monitor
    Havakuk, Ofer
    Sadeh, Ben
    Merdler, Ilan
    Zalevsky, Zeev
    Garcia-Monreal, Javier
    Polani, Sagi
    Arbel, Yaron
    Journal of Medical Engineering and Technology, 2021, 45 (05): : 344 - 350
  • [48] Novel phenotypes of coronavirus disease: a temperature-based trajectory model
    Yanfei Shen
    Dechang Chen
    Xinmei Huang
    Guolong Cai
    Qianghong Xu
    Caibao Hu
    Jing Yan
    Jiao Liu
    Annals of Intensive Care, 11
  • [49] Novel Temperature-Based Topological Indices for Certain Convex Polytopes
    Hayat, Sakander
    Malik, Muhammad Yasir Hayat
    Fazal, Saima
    CONTEMPORARY MATHEMATICS, 2024, 5 (04): : 4726 - 4762
  • [50] A multi-channel acoustics monitor for perioperative respiratory monitoring: preliminary data
    Jafarian, Kamal
    Amineslami, Majid
    Hassani, Kamran
    Navidbakhsh, Mahdi
    Lahiji, Mohammad Niakan
    Doyle, D. John
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2016, 30 (01) : 107 - 118