Magnetic resonance imaging of cortical bone with ultrashort TE pulse sequences

被引:152
|
作者
Reichert, ILH
Robson, MD
Gatehouse, PD
He, TG
Chappell, KE
Holmes, J
Girgis, S
Bydder, GM [1 ]
机构
[1] Univ Calif San Diego, Dept Radiol, San Diego, CA 92103 USA
[2] Charing Cross Hosp, Dept Orthoped Surg, Imperial Coll, Fac Med, London W6 8RF, England
[3] Royal Brompton Hosp, Cardiac Meagnet Resonance Unit, London SW3 6NP, England
[4] Univ Oxford, Dept Cardiovasc Med, Ctr Clin Magnet Resonance Res, Oxford OX1 2JD, England
[5] MRC, Ctr Clin Sci, Imaging Sci Dept, Robert Steiner Magnet Resonance Unit, London W12 0HS, England
[6] Hammersmith Hosp, Fac Med, Imperial Coll, Dept Med, London W12 0HS, England
关键词
magnetic resonance imaging; cortical bone; ultrashort echo time; bone perfusion;
D O I
10.1016/j.mri.2005.02.017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Normal adult cortical bone has a very short T-2 and characteristically produces no signal with pulse sequence echo times (TEs) routinely used in clinical practice. We wished to determine whether it was possible to use ultrashort TE (UTE) pulse sequences to detect signal from cortical bone in human subjects and use this signal to characterise this tissue. Subjects and Methods: Seven volunteers and 10 patients were examined using ultrashort TE pulse sequences (TE = 0.07 or 0.08 ms). Short and long inversion as well as fat suppression pulses were used as preparation pulses. Later echo images were also obtained as well as difference images produced by subtracting a later echo image from a first echo image. Saturation pulses were used for T-1 measurement and sequences with progressively increasing TEs for T-2* measurement. Intravenous gadodiamide was administered to four subjects. Results: Signal in cortical bone was detected with UTE sequences in children, normal adults and patients. This signal was usually made more obvious by subtracting a later echo image from the first provided that the signal-to-noise ratio was sufficiently high. Normal mean adult T(1)s ranged from 140 to 260 ms, and mean T-2*s ranged from 0.42 to 0.50 ms. T-1 increased significantly with age (P < .01). Increased signal was observed after contrast enhancement in the normal volunteer and the three patients to whom it was administered. Reduction in signal from short T-2 components was seen in acute fractures, and increase in signal in these components was seen with new bone formation after fracture malunion. In a case of osteoporosis, bone cross-sectional area and signal level appeared reduced. Conclusion: Signal can be detected from normal and abnormal cortical bone with UTE pulse sequences, and this can be used to measure its T-1 and T2* as well as observe contrast enhancement. Difference images are of value in increasing the conspicuity of cortical bone and observing abnormalities in disease. (c) 2005 Elsevier Inc. All rights reserved.
引用
收藏
页码:611 / 618
页数:8
相关论文
共 50 条
  • [1] Magnetic resonance imaging of the knee with ultrashort TE pulse sequences
    Gatehouse, PD
    Thomas, RW
    Robson, MD
    Hamilton, G
    Herlihy, AH
    Bydder, GM
    MAGNETIC RESONANCE IMAGING, 2004, 22 (08) : 1061 - 1067
  • [2] Magnetic resonance imaging of periosteum with ultrashort TE pulse sequences
    Reichert, ILH
    Benjamin, M
    Gatehouse, PD
    Chappell, KE
    Holmes, J
    He, TG
    Bydder, GM
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 19 (01) : 99 - 107
  • [3] Magnetic resonance imaging of the liver with ultrashort TE (UTE) pulse sequences
    Chappell, KE
    Patel, N
    Gatehouse, PD
    Main, J
    Puri, BK
    Taylor-Robinson, SD
    Bydder, GM
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 18 (06) : 709 - 713
  • [4] Magnetic resonance imaging with ultrashort TE (UTE) PULSE sequences: Technical considerations
    Tyler, Damian J.
    Robson, Matthew D.
    Henkelman, R. Mark
    Young, Ian R.
    Bydder, Graeme M.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (02) : 279 - 289
  • [5] Magnetic resonance imaging of entheses using ultrashort TE (UTE) pulse sequences
    Benjamin, Michael
    Bydder, Graeme M.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (02) : 381 - 389
  • [6] Magnetic resonance imaging of the Achilles tendon using ultrashort TE (UTE) pulse sequences
    Robson, MD
    Benjamin, M
    Gishen, P
    Bydder, GM
    CLINICAL RADIOLOGY, 2004, 59 (08) : 727 - 735
  • [7] Optimization of Black Bone and Ultrashort Echo Time Magnetic Resonance Imaging Sequences for Mandibular Cortical Bone Visualization
    West, N. A.
    Mulder, S.
    McCullum, L.
    Salzillo, T. C.
    Ding, Y.
    Chen, M.
    Wang, J.
    He, R.
    Lai, S. Y.
    Fuller, C. D.
    MEDICAL PHYSICS, 2024, 51 (10) : 7852 - 7852
  • [8] Magnetic resonance imaging of the normal pituitary gland using ultrashort TE (UTE) pulse sequences (REV 1.0)
    Portman, Olivia
    Flemming, Stephen
    Cox, Jeremy P. D.
    Johnston, Desmond G.
    Bydder, Graeme M.
    NEURORADIOLOGY, 2008, 50 (03) : 213 - 220
  • [9] Magnetic resonance imaging of the normal pituitary gland using ultrashort TE (UTE) pulse sequences (REV 1.0)
    Olivia Portman
    Stephen Flemming
    Jeremy P. D. Cox
    Desmond G. Johnston
    Graeme M. Bydder
    Neuroradiology, 2008, 50 : 213 - 220
  • [10] Review of the ultrashort echo time magnetic resonance imaging of cortical bone
    Bao Shang-Lian
    Du Jiang
    Gao Song
    ACTA PHYSICA SINICA, 2013, 62 (08)