Modified optical coefficient measurements using a single high-NA fiber with detection parameter changes at a tip

被引:0
|
作者
Nakazawa, Haruna [1 ]
Doi, Marika [1 ]
Ogawa, Emiyu [2 ]
Arai, Tsunenori [1 ,3 ]
机构
[1] Keio Univ, Grad Sch Sci & Technol, Sch Fundamental Sci & Technol, Kohoku Ku, 3-14-1 Hiyoshi, Yokohama, Kanagawa 2238522, Japan
[2] Kitasato Univ, Sch Allied Hlth Sci, Minami Ku, 1-15-1 Kitasato, Sagamihara, Kanagawa 2520373, Japan
[3] Keio Univ, Fac Sci & Technol, Dept Appl Phys & Physicoinformat, Kohoku Ku, 3-14-1 Hiyoshi, Yokohama, Kanagawa 2238522, Japan
来源
OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS VIII | 2018年 / 10820卷
关键词
optical coefficients; bulk tissue; light intensity measurement; field of view; ray tracing calculation; Inverse Monte Carlo; MYOCARDIUM; TISSUES;
D O I
10.1117/12.2500742
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
To avoid the instability of an optical coefficient measurement using sliced tissue preparation, an attenuation coefficient measurement by puncturing an optical fiber in bulk tissue have been reported. We proposed a modified puncturing method to obtain an absorption coefficient and scattering coefficient by increasing optical information. We used the light intensity measurement through a single high-NA fiber puncturing into an optically thick bulk tissue varying detection parameters, the depth and field of view (FOV), at the tip. The light intensity measurement and ray trace calculation using the Monte Carlo method (inverse or normal) were employed. We constructed the measurement system which can change the FOV at the fiber tip inside the bulk tissue using the variable aperture outside the bulk tissue. A 200 mu m Phi NA:0.5 fiber installed in a 21G needle was punctured down to surface of the bulk tissue to measure light intensity in the bulk tissue. Using homogeneous optical model solution, the accuracy about attenuation coefficients of the constructed experimental system was confirmed. The error in the attenuation coefficient was up to 1.4%. We demonstrated the optical coefficient measurement of porcine myocardium using the proposed method. To fit dependence of the measured attenuation coefficients on FOV, we decided that the absorption coefficient, the scattering coefficient, and anisotropic parameter were 0.2 mm(-1), 10 mm(-1), and 0.96, respectively. We proposed modified puncturing optical coefficient measurement varying depth and FOV. We demonstrated its usefulness on myocardium.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] High-NA optical edge detection via optimized multilayer films
    Xue, Wenjin
    Miller, Owen D
    Journal of Optics (United Kingdom), 2021, 23 (12):
  • [2] High-NA optical edge detection via optimized multilayer films
    Xue, Wenjin
    Miller, Owen D.
    JOURNAL OF OPTICS, 2021, 23 (12)
  • [3] Modified optical coefficient measurement system for bulk tissue using an optical fiber insertion with varying field of view and depth at the fiber tip
    Nakazawa, Haruna
    Doi, Marika
    Ogawa, Emiyu
    Arai, Tsunenori
    LASERS IN MEDICAL SCIENCE, 2019, 34 (08) : 1613 - 1618
  • [4] Modified optical coefficient measurement system for bulk tissue using an optical fiber insertion with varying field of view and depth at the fiber tip
    Haruna Nakazawa
    Marika Doi
    Emiyu Ogawa
    Tsunenori Arai
    Lasers in Medical Science, 2019, 34 : 1613 - 1618
  • [5] Wavefront measurements using the Ronchi test for high-NA lithography projection lenses
    Yu, Xinfeng
    Li, Jiaqi
    APPLIED OPTICS, 2023, 62 (19) : 5057 - 5063
  • [6] Three-dimensional force measurements in optical tweezers formed with high-NA micromirrors
    Merenda, Fabrice
    Grossenbacher, Mathieu
    Jeney, Sylvia
    Forro, Laszlo
    Salathe, Rene-Paul
    OPTICS LETTERS, 2009, 34 (07) : 1063 - 1065
  • [7] Modified rod-in-tube for high-NA tellurite glass fiber fabrication: materials and technologies
    Chen, Qiuling
    Wang, Hui
    Wang, Qingwei
    Chen, Qiuping
    Hao, Yinlei
    APPLIED OPTICS, 2015, 54 (04) : 946 - 952
  • [8] Polymer tapered pillar on a fiber end fabricated by UV irradiation using a high-NA fiber
    Kurisawa, Taiga
    Kamiura, Yoshiki
    Fujikawa, Chiemi
    Mikami, Osamu
    PHOTONICS LETTERS OF POLAND, 2022, 14 (04) : 80 - 82
  • [9] Pixel-based defect detection from high-NA optical projection images
    Xu, Dongbo
    Fuehner, Tim
    Erdmann, Andreas
    APPLIED OPTICS, 2014, 53 (18) : 3866 - 3874
  • [10] A NEWLY DEVELOPED TECHNIQUE FOR DETECTION OF A CONTACT POSITION IN BUBBLE MEASUREMENTS BY A SINGLE-TIP OPTICAL FIBER PROBE
    Mizushima, Yuki
    Saito, Takayuki
    PROCEEDINGS OF THE ASME/JSME/KSME JOINT FLUIDS ENGINEERING CONFERENCE 2011, VOL 1, PTS A-D, 2012, : 2425 - 2431