Modified optical coefficient measurements using a single high-NA fiber with detection parameter changes at a tip

被引:0
|
作者
Nakazawa, Haruna [1 ]
Doi, Marika [1 ]
Ogawa, Emiyu [2 ]
Arai, Tsunenori [1 ,3 ]
机构
[1] Keio Univ, Grad Sch Sci & Technol, Sch Fundamental Sci & Technol, Kohoku Ku, 3-14-1 Hiyoshi, Yokohama, Kanagawa 2238522, Japan
[2] Kitasato Univ, Sch Allied Hlth Sci, Minami Ku, 1-15-1 Kitasato, Sagamihara, Kanagawa 2520373, Japan
[3] Keio Univ, Fac Sci & Technol, Dept Appl Phys & Physicoinformat, Kohoku Ku, 3-14-1 Hiyoshi, Yokohama, Kanagawa 2238522, Japan
来源
OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS VIII | 2018年 / 10820卷
关键词
optical coefficients; bulk tissue; light intensity measurement; field of view; ray tracing calculation; Inverse Monte Carlo; MYOCARDIUM; TISSUES;
D O I
10.1117/12.2500742
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
To avoid the instability of an optical coefficient measurement using sliced tissue preparation, an attenuation coefficient measurement by puncturing an optical fiber in bulk tissue have been reported. We proposed a modified puncturing method to obtain an absorption coefficient and scattering coefficient by increasing optical information. We used the light intensity measurement through a single high-NA fiber puncturing into an optically thick bulk tissue varying detection parameters, the depth and field of view (FOV), at the tip. The light intensity measurement and ray trace calculation using the Monte Carlo method (inverse or normal) were employed. We constructed the measurement system which can change the FOV at the fiber tip inside the bulk tissue using the variable aperture outside the bulk tissue. A 200 mu m Phi NA:0.5 fiber installed in a 21G needle was punctured down to surface of the bulk tissue to measure light intensity in the bulk tissue. Using homogeneous optical model solution, the accuracy about attenuation coefficients of the constructed experimental system was confirmed. The error in the attenuation coefficient was up to 1.4%. We demonstrated the optical coefficient measurement of porcine myocardium using the proposed method. To fit dependence of the measured attenuation coefficients on FOV, we decided that the absorption coefficient, the scattering coefficient, and anisotropic parameter were 0.2 mm(-1), 10 mm(-1), and 0.96, respectively. We proposed modified puncturing optical coefficient measurement varying depth and FOV. We demonstrated its usefulness on myocardium.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Chemically Etched Single Mode Fiber Tip for High Lateral Resolution Imaging in Optical Coherence Tomography
    Taguchi, Kozo
    Totsuka, Masafumi
    PROCEEDINGS OF PRECISION ENGINEERING AND NANOTECHNOLOGY (ASPEN2011), 2012, 516 : 585 - 590
  • [32] Drug delivery and optical neuromodulation using a structured polymer optical fiber with ultra-high NA
    Sui, Kunyang
    Meneghetti, Marcello
    Kaur, Jaspreet
    Sorensen, R. J. F.
    Berg, Rune W.
    Markos, Christos
    OPTOGENETICS AND OPTICAL MANIPULATION 2023, 2023,
  • [33] Temperature measurements in deployed optical fiber networks using single photon optical time domain reflectometry
    Staffas, Theodor
    Troive, Fredrik
    Zwiller, Val
    OPTICS EXPRESS, 2023, 31 (05) : 8170 - 8176
  • [34] Spotsize contraction in standard single-mode fibers by use of a GI-fiber tip with a high focusing parameter
    Shiraishi, K
    Ogura, A
    Matsuura, K
    IEEE PHOTONICS TECHNOLOGY LETTERS, 1998, 10 (12) : 1757 - 1759
  • [35] Evaluation of the influences of surface tension on the bubble measurement using a single-tip optical fiber probe
    Ozawa, Yusuke
    Saito, Takayuki
    FEDSM 2007: PROCEEDINGS OF THE 5TH JOINT AMSE/JSME FLUIDS ENGINEERING SUMMER CONFERENCE VOL 1, PTS A AND B, 2007, : 533 - 541
  • [36] High-sensitivity bend angle measurements using optical fiber gratings
    Rauf, Abdul
    Zhao, Jianlin
    Jiang, Biqiang
    APPLIED OPTICS, 2013, 52 (21) : 5072 - 5078
  • [37] Temperature measurements using a high-temperature blackbody optical fiber thermometer
    Barker, DG
    Jones, MR
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2003, 125 (03): : 471 - 477
  • [38] High sensitivity detection of ATP using bioluminescence at an optical fiber end
    Hiroshima University, ADSM, Department of Quantum Matter, 1-3-1 Kagamiyama, Higashi-Hiroshima, Hiroshima 739-8530, Japan
    不详
    不详
    不详
    IEEJ Trans. Electron. Inf. Syst., 2007, 10 (1498-1503+1):
  • [39] Bubble Size Measurements in Breaking Waves Using Optical Fiber Phase Detection Probes
    Blenkinsopp, Christopher E.
    Chaplin, John R.
    IEEE JOURNAL OF OCEANIC ENGINEERING, 2010, 35 (02) : 388 - 401
  • [40] High-NA 2D Image Edge Detection Using Tamm Plasmon Polaritons in Few-Layer Stratified Media
    Dias, Bernardo S.
    van de Groep, Jorik
    ACS PHOTONICS, 2024, 12 (01): : 311 - 319