Modified optical coefficient measurements using a single high-NA fiber with detection parameter changes at a tip

被引:0
|
作者
Nakazawa, Haruna [1 ]
Doi, Marika [1 ]
Ogawa, Emiyu [2 ]
Arai, Tsunenori [1 ,3 ]
机构
[1] Keio Univ, Grad Sch Sci & Technol, Sch Fundamental Sci & Technol, Kohoku Ku, 3-14-1 Hiyoshi, Yokohama, Kanagawa 2238522, Japan
[2] Kitasato Univ, Sch Allied Hlth Sci, Minami Ku, 1-15-1 Kitasato, Sagamihara, Kanagawa 2520373, Japan
[3] Keio Univ, Fac Sci & Technol, Dept Appl Phys & Physicoinformat, Kohoku Ku, 3-14-1 Hiyoshi, Yokohama, Kanagawa 2238522, Japan
来源
OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS VIII | 2018年 / 10820卷
关键词
optical coefficients; bulk tissue; light intensity measurement; field of view; ray tracing calculation; Inverse Monte Carlo; MYOCARDIUM; TISSUES;
D O I
10.1117/12.2500742
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
To avoid the instability of an optical coefficient measurement using sliced tissue preparation, an attenuation coefficient measurement by puncturing an optical fiber in bulk tissue have been reported. We proposed a modified puncturing method to obtain an absorption coefficient and scattering coefficient by increasing optical information. We used the light intensity measurement through a single high-NA fiber puncturing into an optically thick bulk tissue varying detection parameters, the depth and field of view (FOV), at the tip. The light intensity measurement and ray trace calculation using the Monte Carlo method (inverse or normal) were employed. We constructed the measurement system which can change the FOV at the fiber tip inside the bulk tissue using the variable aperture outside the bulk tissue. A 200 mu m Phi NA:0.5 fiber installed in a 21G needle was punctured down to surface of the bulk tissue to measure light intensity in the bulk tissue. Using homogeneous optical model solution, the accuracy about attenuation coefficients of the constructed experimental system was confirmed. The error in the attenuation coefficient was up to 1.4%. We demonstrated the optical coefficient measurement of porcine myocardium using the proposed method. To fit dependence of the measured attenuation coefficients on FOV, we decided that the absorption coefficient, the scattering coefficient, and anisotropic parameter were 0.2 mm(-1), 10 mm(-1), and 0.96, respectively. We proposed modified puncturing optical coefficient measurement varying depth and FOV. We demonstrated its usefulness on myocardium.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] DISTRIBUTED SINGLE-MODE OPTICAL FIBER HIGH TEMPERATURES MEASUREMENTS
    Hlifka, Brian M.
    Kinzel, Edward C.
    PROCEEDINGS OF ASME 2024 HEAT TRANSFER SUMMER CONFERENCE, HT 2024, 2024,
  • [22] MEASUREMENTS OF ABSORPTION-COEFFICIENT IN FIBER OPTICAL-WAVEGUIDES USING A CALORIMETRIC TECHNIQUE
    PINNOW, DA
    RICH, TC
    APPLIED OPTICS, 1975, 14 (06): : 1258 - 1259
  • [23] High-NA two-photon single cell imaging with remote focusing using a diffractive tunable lens
    May, Molly A.
    Bawart, Martin
    Langeslag, Michiel
    Bernet, Stefan
    Kress, Michaela
    Ritsch-Marte, Monika
    Jesacher, Alexander
    BIOMEDICAL OPTICS EXPRESS, 2020, 11 (12): : 7183 - 7191
  • [24] Efficient PDFA module using high-NA PbF2/InF3-based fluoride fiber
    Nishida, Y
    Kanamori, T
    Ohishi, Y
    Yamada, M
    Kobayashi, K
    Sudo, S
    IEEE PHOTONICS TECHNOLOGY LETTERS, 1997, 9 (03) : 318 - 320
  • [25] Single Nanoparticle Detection and Sizing by Using a Nanoscale Optical Fiber
    Yu, Xiao-Chong
    Li, Bei-Bei
    Wang, Pan
    Tong, Limin
    Gong, Qihuang
    Xiao, Yun-Feng
    2014 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2014,
  • [26] High-density all-optical magnetic recording using a high-NA lens illuminated by circularly polarized pulse lights
    Zhang, Yaoju
    Bai, Jianping
    PHYSICS LETTERS A, 2008, 372 (41) : 6294 - 6297
  • [27] Tapered single mode fiber tip for high lateral resolution imaging in Optical Coherence Tomography
    Verma, Y.
    Rao, K. Divakar
    Mohanty, S. K.
    Gupta, P. K.
    COMPLEX DYNAMICS AND FLUCTUATIONS IN BIOMEDICAL PHOTONICS IV, 2007, 6436
  • [28] Multilayer silver nanoparticles-modified optical fiber tip for high performance SERS remote sensing
    Andrade, Gustavo F. S.
    Fan, MeiKun
    Brolo, Alexandre G.
    BIOSENSORS & BIOELECTRONICS, 2010, 25 (10): : 2270 - 2275
  • [29] Compensation of high-NA mask topography effects by using object modified Kirchhoff model for 65 and 45nm nodes
    Aksenov, Yuri
    Zandbergen, Peter
    Yoshizawa, Masaki
    OPTICAL MICROLITHOGRAPHY XIX, PTS 1-3, 2006, 6154 : U613 - U622
  • [30] Nanoparticle detection using Fano-resonance photonic crystal on optical fiber-tip
    Yang, Daquan
    Yuan, Wei
    Ji, Yuefeng
    OPTICAL COMMUNICATION AND OPTICAL FIBER SENSORS AND OPTICAL MEMORIES FOR BIG DATA STORAGE, 2016, 10158