Refractive and Visual Outcomes After Intacs vs Ferrara Intrastromal Corneal Ring Segment Implantation for Keratoconus: A Comparative Study

被引:29
|
作者
Kaya, Vedat [2 ]
Utine, Canan Asli [1 ]
Karakus, Sezen Harmanci [2 ]
Kavadarli, Isilay [2 ]
Yilmaz, Omer Faruk [2 ]
机构
[1] Yeditepe Univ, Dept Ophthalmol, TR-34345 Istanbul, Turkey
[2] Beyoglu Eye Res & Training Hosp, Istanbul, Turkey
关键词
TERM-FOLLOW-UP; FEMTOSECOND LASER; MANAGEMENT; MODERATE; PERFORMANCE; EFFICACY; MODELS;
D O I
10.3928/1081597X-20110906-03
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate the refractive, topographic, optical, visual acuity, and quality outcomes of two types of intrastromal corneal ring segments (ICRS) in the treatment of keratoconus. METHODS: In this retrospective study, 16 eyes that had been implanted with Intacs ICRS (Addition Technology Inc) (Intacs group) and 17 eyes implanted with Ferrara ICRS (Ferrara Ophthalmics Ltda) (Ferrara group) were evaluated. Pre- and postoperative examinations included uncorrected and corrected distance visual acuities (UDVA and CDVA, respectively), manifest refraction, slit-lamp examination, topography, and ocular wavefront analysis. Contrast sensitivity measurements under photopic, scotopic, and scotopic with glare conditions were performed 1 year postoperatively. RESULTS: One year postoperatively, a significant decrease was noted in spherical equivalent refractive error of 3.76 +/- 0.39 diopters (D) and 3.42 +/- 0.88 D and keratometry of 3.43 +/- 0.24 D and 3.28 +/- 0.78 D in the Intacs and Ferrara groups, respectively; and increase in mean UDVA and CDVA in Snellen lines of 0.18 +/- 0.04 and 0.21 +/- 0.05, respectively, in the Intacs group and 0.21 +/- 0.09 and 0.26 +/- 0.08, respectively, in the Ferrara group (P<.01 for all). The postoperative increase in UDVA and CDVA and decrease in keratometry readings were not significantly different between groups (P>.05 for all). Mean higher order aberrations decreased in the Intacs group and increased in the Ferrara group (P>.05 for both). Postoperatively, a signifi cant decrease was noted in scotopic contrast sensitivity when glare was introduced in the Ferrara group, which was positively correlated with pupil diameter (r(15)= 0.50, P=.04). CONCLUSIONS: Both ICRS types provided comparable refractive, topographic, and optical quality outcomes. Eyes with Ferrara ICRS experienced greater decrease in scotopic contrast sensitivity under glare, which was significantly correlated with pupil diameter. [J Refract Surg. 2011; 27(12): 907-912.] doi:10.3928/1081597X-20110906-03
引用
收藏
页码:907 / 912
页数:6
相关论文
共 50 条
  • [21] Soft contact lens fitting after intrastromal corneal ring segment implantation to treat keratoconus
    Carballo-Alvarez, J.
    Puell, M. C.
    Cuina, R.
    Diaz-Valle, D.
    Vazquez, J. M.
    Benitez-del-Castillo, J. M.
    CONTACT LENS & ANTERIOR EYE, 2014, 37 (05): : 377 - 381
  • [22] Forward light scatter and visual acuity before and after intrastromal corneal ring segment implantation at different stages of keratoconus
    Cinta Puell, Maria
    Carballo-Alvarez, Jesus
    ACTA OPHTHALMOLOGICA, 2016, 94 (08) : E738 - E743
  • [23] Evaluation of keratoconus progression and visual improvement after intrastromal corneal ring segments implantation: A retrospective study
    Moscovici, Bernardo Kaplan
    Rodrigues, Pablo Felipe
    Rodrigues, Renan Albert Mendonca
    Rios, Livia Cristina
    Simoncelli, Rosangela
    Freitas, Marcela Mara Silva
    Torquetti, Leonardo
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (06) : 3483 - 3489
  • [24] Changes in Anterior and Posterior Corneal Parameters in Patients with Keratoconus After Intrastromal Corneal-ring Segment Implantation
    Rho, Chang Rae
    Na, Kyung-Sun
    Yoo, Young Sik
    Pandey, Chitra
    Park, Chang Won
    Joo, Choun-Ki
    CURRENT EYE RESEARCH, 2013, 38 (08) : 843 - 850
  • [25] Indications and visual outcomes of intrastromal corneal ring segment implantation in a large patient series
    Tognon, Taise
    Campos, Mauro
    Wengrzynovski, Joao Paulo
    Barella, Kleyton Arlindo
    Pasqualotti, Adriano
    de Brito Martins, Luiz Antonio
    Forseto, Adriana dos Santos
    de Sousa, Luciene Barbosa
    CLINICS, 2017, 72 (06) : 370 - 377
  • [26] Femtosecond Laser Assisted Intrastromal Corneal Ring Segment (Keraring) Implantation in Keratoconus
    Kusumenr, Raciha Beni
    Basar, Demir
    Alimgil, Murat Levant
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2009, 39 (02): : 96 - 102
  • [27] Double intrastromal corneal ring segment implantation: a new approach for improved clinical outcomes in keratoconus patients
    Coscarelli, Sandro
    Sieiro, Reinaldo de Oliveira
    Fernandes, Victoria Moreira
    Coscarelli, Sandro P.
    Torquetti, Leonardo
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2024, 17 (11) : 2023 - 2030
  • [28] Corneal Collagen Cross-Linking Before Ferrara Intrastromal Corneal Ring Implantation for the Treatment of Progressive Keratoconus
    Henriquez, Maria A.
    Izquierdo, Luis, Jr.
    Bernilla, Cesar
    McCarthy, Martin
    CORNEA, 2012, 31 (07) : 740 - 745
  • [29] Changes in visual function under mesopic and photopic conditions after intrastromal corneal ring segment implantation for different stages of keratoconus
    Carballo, Jesus
    Cinta Puell, Maria
    Cuina, Ricardo
    Maria Vazquez, Jose
    Benitez-del-Castillo, Jose M.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (03): : 393 - 402
  • [30] Refractive and biometric changes after implantation of the intrastromal corneal ring
    Twa, MD
    Schanzlin, DJ
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S105 - S105