Refractive and Visual Outcomes After Intacs vs Ferrara Intrastromal Corneal Ring Segment Implantation for Keratoconus: A Comparative Study

被引:29
|
作者
Kaya, Vedat [2 ]
Utine, Canan Asli [1 ]
Karakus, Sezen Harmanci [2 ]
Kavadarli, Isilay [2 ]
Yilmaz, Omer Faruk [2 ]
机构
[1] Yeditepe Univ, Dept Ophthalmol, TR-34345 Istanbul, Turkey
[2] Beyoglu Eye Res & Training Hosp, Istanbul, Turkey
关键词
TERM-FOLLOW-UP; FEMTOSECOND LASER; MANAGEMENT; MODERATE; PERFORMANCE; EFFICACY; MODELS;
D O I
10.3928/1081597X-20110906-03
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate the refractive, topographic, optical, visual acuity, and quality outcomes of two types of intrastromal corneal ring segments (ICRS) in the treatment of keratoconus. METHODS: In this retrospective study, 16 eyes that had been implanted with Intacs ICRS (Addition Technology Inc) (Intacs group) and 17 eyes implanted with Ferrara ICRS (Ferrara Ophthalmics Ltda) (Ferrara group) were evaluated. Pre- and postoperative examinations included uncorrected and corrected distance visual acuities (UDVA and CDVA, respectively), manifest refraction, slit-lamp examination, topography, and ocular wavefront analysis. Contrast sensitivity measurements under photopic, scotopic, and scotopic with glare conditions were performed 1 year postoperatively. RESULTS: One year postoperatively, a significant decrease was noted in spherical equivalent refractive error of 3.76 +/- 0.39 diopters (D) and 3.42 +/- 0.88 D and keratometry of 3.43 +/- 0.24 D and 3.28 +/- 0.78 D in the Intacs and Ferrara groups, respectively; and increase in mean UDVA and CDVA in Snellen lines of 0.18 +/- 0.04 and 0.21 +/- 0.05, respectively, in the Intacs group and 0.21 +/- 0.09 and 0.26 +/- 0.08, respectively, in the Ferrara group (P<.01 for all). The postoperative increase in UDVA and CDVA and decrease in keratometry readings were not significantly different between groups (P>.05 for all). Mean higher order aberrations decreased in the Intacs group and increased in the Ferrara group (P>.05 for both). Postoperatively, a signifi cant decrease was noted in scotopic contrast sensitivity when glare was introduced in the Ferrara group, which was positively correlated with pupil diameter (r(15)= 0.50, P=.04). CONCLUSIONS: Both ICRS types provided comparable refractive, topographic, and optical quality outcomes. Eyes with Ferrara ICRS experienced greater decrease in scotopic contrast sensitivity under glare, which was significantly correlated with pupil diameter. [J Refract Surg. 2011; 27(12): 907-912.] doi:10.3928/1081597X-20110906-03
引用
收藏
页码:907 / 912
页数:6
相关论文
共 50 条
  • [31] Microbial Keratitis After Intrastromal Corneal Ring Segment Implantation
    Emilia Mulet, M.
    Perez-Santonja, Juan J.
    Ferrer, Consuelo
    Alio, Jorge L.
    JOURNAL OF REFRACTIVE SURGERY, 2010, 26 (05) : 364 - 369
  • [32] Clinical Outcomes After Implantation of 320°-Arc Length Intrastromal Corneal Ring Segments in Keratoconus
    Torquetti, Leonardo
    Cunha, Priscila
    Luz, Allan
    Kwitko, Sergio
    Carrion, Marcio
    Rocha, Guilherme
    Signorelli, Armando
    Coscarelli, Sandro
    Ferrara, Guilherme
    Bicalho, Frederico
    Neves, Renato
    Ferrara, Paulo
    CORNEA, 2018, 37 (10) : 1299 - 1305
  • [33] Intrastromal Corneal Ring Segment Explantation in Patients With Keratoconus: Causes, Technique, and Outcomes
    Chhadva, Priyanka
    Yesilirmak, Nilufer
    Cabot, Florence
    Yoo, Sonia H.
    JOURNAL OF REFRACTIVE SURGERY, 2015, 31 (06) : 392 - U105
  • [34] Comparison of intrastromal corneal ring segment implantation only and in combination with collagen crosslinking for keratoconus
    Cakir, Hanefi
    Pekel, Gokhan
    Perente, Irfan
    Genc, Selim
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2013, 23 (05) : 629 - 634
  • [35] Intrastromal corneal ring segment implantation in paracentral keratoconus with coincident topographic and coma axis
    Alfonso, Jose F.
    Lisa, Carlos
    Merayo-Lloves, Jesus
    Fernandez-Vega Cueto, Luis
    Montes-Mico, Robert
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (09): : 1576 - 1582
  • [36] Intrastromal Corneal Ring Segment Implantation in a Patient with the Bowman Layer Inlay Transplantation for Keratoconus
    Ramalhao, Joao Ponces
    Neves, Miguel Mesquita
    Gomes, Miguel
    Oliveira, Luis
    CASE REPORTS IN OPHTHALMOLOGICAL MEDICINE, 2023, 2023
  • [37] Preliminary results of intrastromal corneal ring segment implantation to treat moderate to severe keratoconus
    Hamdi, Islam M.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (06): : 1125 - 1132
  • [38] Corneal densitometry changes in keratoconus patients after intrastromal corneal ring segments implantation
    Basiony, Ahmed I.
    Abdulfattah, Mohammad M. E. Mohammad
    Ibrahim, Asmaa M.
    JOURNAL OF THE EGYPTIAN OPHTHALMOLOGICAL SOCIETY, 2024, 117 (01) : 28 - 38
  • [39] Keratitis after implantation of intrastromal corneal ring segments (Intacs) aided by femtosecond laser for keratoconus correction: case report and description of the literature
    Levy, Jaime
    Lifshitz, Tova
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2010, 20 (04) : 780 - 784
  • [40] Scheimpflug Corneal Densitometry Changes After the Intrastromal Corneal Ring Segment Implantation
    Sedaghat, Mohammad-Reza
    Momeni-Moghaddam, Hamed
    Heravian, Javad
    Belin, Michael W.
    Ambrosio, Renato, Jr.
    Gheysari-Alishahi, Tayebe
    Ghavami, Seyyed Hossein
    CORNEA, 2020, 39 (06) : 761 - 768