PURPOSE: To analyze and compare the changes in visual function under mesopic and photopic conditions in different stages of keratoconus before and after Keraring intrastromal corneal ring segment (ICRS) implantation. SETTING: Clinico San Carlos Hospital and Faculty of Optics and Optometry, Complutense University, Madrid, Spain. DESIGN: Case series. METHODS: Keratoconic eyes were evaluated under mesopic (0.1 to 0.2 candelas [cd]/m(2)) and photopic (85 cd/m(2)) conditions. LogMAR high-contrast corrected distance visual acuity (CDVA) and low-contrast CDVA were assessed using the Bailey-Lovie test and logarithmic contrast sensitivity, using the Pelli-Robson test. RESULTS: The study evaluated 12 eyes with stage I keratoconus, 21 eyes with stage 2, and 14 eyes with stage 3. The mean change in photopic high-contrast CDVA was 0.16 logMAR +/- 0.20 (SD) (P<.00001). Photopic low-contrast CDVA increased by a mean of 0.14 +/- 0.26 logMAR (P=.0005), photopic contrast sensitivity by a mean of 0.09 +/- 0.22 logMAR (P=.005), and mesopic high-contrast CDVA by a mean of 0.10 +/- 0.26 logMAR (P=.03). There were no significant differences between stages. Surgery did not affect the mean changes in mesopic low-contrast CDVA or mesopic contrast sensitivity for any stage. CONCLUSIONS: Implantation of ICRS in keratoconic eyes increased photopic high-contrast CDVA, low-contrast CDVA, and contrast sensitivity. Under low luminance, the mean changes in high-contrast CDVA, low-contrast CDVA, and contrast sensitivity did not worsen after ICRS implantation performed 5.0 mm from the visual axis, despite the rings being partially superimposed on the mydriatic pupil. Financial Disclosure: No author has a financial or proprietary interest in any material or method mentioned. J Cataract Refract Surg 2013; 39:393-402 (C) 2012 ASCRS and ESCRS
引用
收藏
页码:393 / 402
页数:10
相关论文
共 50 条
  • [1] Forward light scatter and visual acuity before and after intrastromal corneal ring segment implantation at different stages of keratoconus
    Cinta Puell, Maria
    Carballo-Alvarez, Jesus
    ACTA OPHTHALMOLOGICA, 2016, 94 (08) : E738 - E743
  • [2] Acute corneal hydrops after intrastromal corneal ring segment implantation for keratoconus
    Gueell, Jose L.
    Verdaguer, Paula
    Elies, Daniel
    Gris, Oscar
    Manero, Felicidad
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (12): : 2192 - 2195
  • [3] Intrastromal Corneal Ring Segment Implantation for the Treatment of Keratoconus
    Kubaloglu, Anil
    Sari, Esin Sogutlu
    Cinar, Yasin
    Koytak, Arif
    Kurnaz, Ekrem
    Ozerturk, Yusuf
    CORNEA, 2011, 30 (01) : 11 - 17
  • [4] Changes in Anterior and Posterior Corneal Parameters in Patients with Keratoconus After Intrastromal Corneal-ring Segment Implantation
    Rho, Chang Rae
    Na, Kyung-Sun
    Yoo, Young Sik
    Pandey, Chitra
    Park, Chang Won
    Joo, Choun-Ki
    CURRENT EYE RESEARCH, 2013, 38 (08) : 843 - 850
  • [5] Corneal densitometry changes in keratoconus patients after intrastromal corneal ring segments implantation
    Basiony, Ahmed I.
    Abdulfattah, Mohammad M. E. Mohammad
    Ibrahim, Asmaa M.
    JOURNAL OF THE EGYPTIAN OPHTHALMOLOGICAL SOCIETY, 2024, 117 (01) : 28 - 38
  • [6] Scheimpflug Corneal Densitometry Changes After the Intrastromal Corneal Ring Segment Implantation
    Sedaghat, Mohammad-Reza
    Momeni-Moghaddam, Hamed
    Heravian, Javad
    Belin, Michael W.
    Ambrosio, Renato, Jr.
    Gheysari-Alishahi, Tayebe
    Ghavami, Seyyed Hossein
    CORNEA, 2020, 39 (06) : 761 - 768
  • [7] Intrastromal corneal ring segment implantation in 219 keratoconic eyes at different stages
    Alfonso, Jose F.
    Lisa, Carlos
    Fernandez-Vega, Luis
    Madrid-Costa, David
    Montes-Mico, Robert
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 249 (11) : 1705 - 1712
  • [8] Intrastromal corneal ring segment implantation in 219 keratoconic eyes at different stages
    José F. Alfonso
    Carlos Lisa
    Luis Fernández-Vega
    David Madrid-Costa
    Robert Montés-Micó
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2011, 249 : 1705 - 1712
  • [9] INTACS Followed by KeraRing Intrastromal Corneal Ring Segment Implantation for Keratoconus
    Coskunseven, Efekan
    Kymionis, George D.
    Grentzelos, Michael A.
    Karavitaki, Alexandra E.
    Portaliou, Dimitra M.
    Jankov, Mirko R., II
    Arslan, Ebru
    JOURNAL OF REFRACTIVE SURGERY, 2010, 26 (05) : 371 - 374
  • [10] Intrastromal corneal ring segment implantation by femtosecond laser for keratoconus correction