Changes in visual function under mesopic and photopic conditions after intrastromal corneal ring segment implantation for different stages of keratoconus

被引:11
|
作者
Carballo, Jesus [1 ]
Cinta Puell, Maria [1 ]
Cuina, Ricardo [2 ]
Maria Vazquez, Jose [1 ]
Benitez-del-Castillo, Jose M. [2 ]
机构
[1] Univ Complutense, Appl Vis Res Grp, Fac Opt & Optometry, Madrid 28037, Spain
[2] Clin San Carlos Hosp, Madrid, Spain
来源
关键词
FEMTOSECOND LASER; INTACS; MANAGEMENT; OUTCOMES; EYES;
D O I
10.1016/j.jcrs.2012.09.025
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To analyze and compare the changes in visual function under mesopic and photopic conditions in different stages of keratoconus before and after Keraring intrastromal corneal ring segment (ICRS) implantation. SETTING: Clinico San Carlos Hospital and Faculty of Optics and Optometry, Complutense University, Madrid, Spain. DESIGN: Case series. METHODS: Keratoconic eyes were evaluated under mesopic (0.1 to 0.2 candelas [cd]/m(2)) and photopic (85 cd/m(2)) conditions. LogMAR high-contrast corrected distance visual acuity (CDVA) and low-contrast CDVA were assessed using the Bailey-Lovie test and logarithmic contrast sensitivity, using the Pelli-Robson test. RESULTS: The study evaluated 12 eyes with stage I keratoconus, 21 eyes with stage 2, and 14 eyes with stage 3. The mean change in photopic high-contrast CDVA was 0.16 logMAR +/- 0.20 (SD) (P<.00001). Photopic low-contrast CDVA increased by a mean of 0.14 +/- 0.26 logMAR (P=.0005), photopic contrast sensitivity by a mean of 0.09 +/- 0.22 logMAR (P=.005), and mesopic high-contrast CDVA by a mean of 0.10 +/- 0.26 logMAR (P=.03). There were no significant differences between stages. Surgery did not affect the mean changes in mesopic low-contrast CDVA or mesopic contrast sensitivity for any stage. CONCLUSIONS: Implantation of ICRS in keratoconic eyes increased photopic high-contrast CDVA, low-contrast CDVA, and contrast sensitivity. Under low luminance, the mean changes in high-contrast CDVA, low-contrast CDVA, and contrast sensitivity did not worsen after ICRS implantation performed 5.0 mm from the visual axis, despite the rings being partially superimposed on the mydriatic pupil. Financial Disclosure: No author has a financial or proprietary interest in any material or method mentioned. J Cataract Refract Surg 2013; 39:393-402 (C) 2012 ASCRS and ESCRS
引用
收藏
页码:393 / 402
页数:10
相关论文
共 50 条
  • [21] Microbial Keratitis After Intrastromal Corneal Ring Segment Implantation
    Emilia Mulet, M.
    Perez-Santonja, Juan J.
    Ferrer, Consuelo
    Alio, Jorge L.
    JOURNAL OF REFRACTIVE SURGERY, 2010, 26 (05) : 364 - 369
  • [22] Anterior Segment Changes After Femtosecond Laser-Assisted Implantation of a 355-Degree Intrastromal Corneal Ring Segment in Advanced Keratoconus
    Abd Elaziz, Mohamed Samy
    Sarhan, Abdel Rahman El Saebay
    Ibrahim, Asmaa Mohammed
    Haggag, Haidy Abd Elshafy
    CORNEA, 2018, 37 (11) : 1438 - 1443
  • [23] Comparison of intrastromal corneal ring segment implantation only and in combination with collagen crosslinking for keratoconus
    Cakir, Hanefi
    Pekel, Gokhan
    Perente, Irfan
    Genc, Selim
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2013, 23 (05) : 629 - 634
  • [24] Intrastromal corneal ring segment implantation in paracentral keratoconus with coincident topographic and coma axis
    Alfonso, Jose F.
    Lisa, Carlos
    Merayo-Lloves, Jesus
    Fernandez-Vega Cueto, Luis
    Montes-Mico, Robert
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (09): : 1576 - 1582
  • [25] Outcomes of 320-degree intrastromal corneal ring segment implantation for advanced keratoconus
    Chen, Nan-Ni
    Sun, Chi-Chin
    TAIWAN JOURNAL OF OPHTHALMOLOGY, 2024, 14 (01) : 78 - 82
  • [26] Intrastromal Corneal Ring Segment Implantation in a Patient with the Bowman Layer Inlay Transplantation for Keratoconus
    Ramalhao, Joao Ponces
    Neves, Miguel Mesquita
    Gomes, Miguel
    Oliveira, Luis
    CASE REPORTS IN OPHTHALMOLOGICAL MEDICINE, 2023, 2023
  • [27] Preliminary results of intrastromal corneal ring segment implantation to treat moderate to severe keratoconus
    Hamdi, Islam M.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (06): : 1125 - 1132
  • [28] Implantation of a Complete Intrastromal Corneal Ring at 2 Different Stromal Depths in Keratoconus
    Jabbarvand, Mahmoud
    Hashemi, Hassan
    Mohammadpour, Mehrdad
    Khojasteh, Hassan
    Khodaparast, Mehdi
    Hashemian, Hesam
    CORNEA, 2014, 33 (02) : 141 - 144
  • [29] Evaluation of keratoconus progression and visual improvement after intrastromal corneal ring segments implantation: A retrospective study
    Moscovici, Bernardo Kaplan
    Rodrigues, Pablo Felipe
    Rodrigues, Renan Albert Mendonca
    Rios, Livia Cristina
    Simoncelli, Rosangela
    Freitas, Marcela Mara Silva
    Torquetti, Leonardo
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (06) : 3483 - 3489
  • [30] Tomographic Findings After Implantation of Ferrara Intrastromal Corneal Ring Segments in Keratoconus
    Lyra, Joao Marcelo
    Lyra, Daniela
    Ribeiro, Guilherme
    Torquetti, Leonardo
    Ferrara, Paulo
    Machado, Aydano
    JOURNAL OF REFRACTIVE SURGERY, 2017, 33 (02) : 110 - +