Reproducibility of Peripapillary Retinal Nerve Fiber Layer Thickness and Optic Nerve Head Parameters Measured with Cirrus HD-OCT in Glaucomatous Eyes

被引:224
|
作者
Mwanza, Jean-Claude [1 ]
Chang, Robert T. [1 ]
Budenz, Donald L. [1 ]
Durbin, Mary K. [2 ]
Gendy, Mohamed G. [1 ]
Shi, Wei [1 ]
Feuer, William J. [1 ]
机构
[1] Univ Miami, Miller Sch Med, Bascom Palmer Eye Inst, Miami, FL 33136 USA
[2] Carl Zeiss Meditec Inc, Dublin, CA USA
基金
美国国家卫生研究院;
关键词
COHERENCE TOMOGRAPHY; SPECTRAL-DOMAIN; VARIABILITY; DISC; AGREEMENT;
D O I
10.1167/iovs.10-5222
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To assess the reproducibility of peripapillary retinal nerve fiber layer (RNFL) thickness and optic nerve head (ONH) parameters measured with Cirrus HD-OCT in glaucomatous eyes. METHODS. Fifty-five glaucomatous eyes were included in the study. The optic disc cube 200 x 200 protocol was used to obtain three scans during the same visit to evaluate the intravisit reproducibility. One scan on 4 additional days within a 2-month period of the first session was obtained to assess intervisit reproducibility. Intraclass correlation coefficient (ICC), coefficient of variation (CV), and test-retest SD (TRT SD) were calculated for each RNFL and ONH parameter. The formula 1.645 x root 2 x intervisit TRT SD provides an upper tolerance limit to variability beyond which nonphysiologic change should be considered. RESULTS. All ICCs were excellent, ranging from 83.9% to 99.2% for intravisit measurements and from 80.8% to 99.1% for intervisit measurements. Cup/disc area ratio had the lowest CV (1.1%) in either type of measurement, followed by average RNFL thickness (1.9% and 2.7%). Nasal clock hours and quadrants showed the poorest reproducibility as did the clock hour directly temporally. The intervisit tolerance limit for average RNFL thickness was 3.89 mu m. CONCLUSIONS. Intravisit and intervisit measurements of peripapillary RNFL thickness and ONH parameters with Cirrus HD-OCT showed excellent reproducibility, indicating that this instrument may be useful in monitoring glaucoma progression. When comparing two measurements from the same eye on two different visits, a reproducible decrease in average RNFL thickness of approximately 4 mu m or more may be considered a statistically significant change from baseline. (Invest Ophthalmol Vis Sci. 2010;51:5724-5730) DOI:10.1167/iovs.10-5222
引用
收藏
页码:5724 / 5730
页数:7
相关论文
共 50 条
  • [41] Evaluation of Peripapillary Choroidal and Retinal Nerve Fiber Layer Thickness in Eyes with Tilted Optic Disc
    Ozcimen, Muammer
    Sakarya, Yasar
    Goktas, Sertan
    Sakarya, Rabia
    Ivacik, Ismail Senol
    Bukus, Abdulkadir
    OPHTHALMOLOGICA, 2014, 232 : 74 - 74
  • [42] Nerve fiber analyzer measuring retinal nerve fiber layer thickness in normal and glaucomatous eyes
    李润婷
    余晓临
    杨国华
    王谷珠
    眼科研究, 1999, (04) : 3 - 5+36
  • [43] Changes in Retinal Nerve Fiber Layer Thickness After Optic Disc Hemorrhage in Glaucomatous Eyes
    Hwang, Young Hoon
    Kim, Yong Yeon
    Kim, Hwang Ki
    Sohn, Yong Ho
    JOURNAL OF GLAUCOMA, 2014, 23 (08) : 547 - 552
  • [44] Relationship Between Optic Nerve Head Area and Peripapillary Retinal Nerve Fiber Layer Thickness in Laboratory Beagles
    Dwyer, Colleen E.
    Harman, Christine D.
    Haught, Mylee R.
    Lawrence, Frank R.
    Jacobson, Amanda L.
    Koehl, Kristin L.
    Komaromy, Andras M.
    VETERINARY OPHTHALMOLOGY, 2025,
  • [45] Adjusted Peripapillary Retinal Nerve Fiber Layer Thickness Measurements Based on the Optic Nerve Head Scan Angle
    Hong, Samin
    Kim, Chan Yun
    Seong, Gong Je
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (08) : 4067 - 4074
  • [46] Effect of peripapillary retinoschisis on retinal nerve fibre layer thickness measurement in glaucomatous eyes
    Hwang, Young Hoon
    Kim, Yong Yeon
    Kim, Hwang Ki
    Sohn, Yong Ho
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2014, 98 (05) : 669 - 674
  • [47] Retinal nerve fiber layer thickness in children measured with OCT
    Salchow, DJ
    Chiang, MF
    Tsai, J
    Langton, K
    Al-Aswad, LA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [48] REPEATABILITY AND REPRODUCIBILITY OF OPTIC NERVE HEAD AND RETINAL NERVE FIBER LAYER PARAMETER MEASUREMENTS WITH THE HEIDELBERG SPECTRALIS OCT
    Mardin, Christian Y.
    Schrems, Wolfgang
    Schrems-Hoesl, Laura -Maria
    Laemmer, Robert
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [49] Pitfalls in OCT measurement of peripapillary retinal nerve fiber layer thickness in nonglaucomatous optic neuropathy - Reply
    Chan, Carmen K. M.
    Miller, Neil R.
    JOURNAL OF NEURO-OPHTHALMOLOGY, 2008, 28 (02) : 160 - 160
  • [50] Reproducibility of peripapillary retinal nerve fiber layer thickness with spectral domain cirrus high-definition optical coherence tomography in normal eyes
    Hong, Samin
    Kim, Chan Yun
    Lee, Won Seok
    Seong, Gong Je
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2010, 54 (01) : 43 - 47