Reproducibility of Peripapillary Retinal Nerve Fiber Layer Thickness and Optic Nerve Head Parameters Measured with Cirrus HD-OCT in Glaucomatous Eyes

被引:224
|
作者
Mwanza, Jean-Claude [1 ]
Chang, Robert T. [1 ]
Budenz, Donald L. [1 ]
Durbin, Mary K. [2 ]
Gendy, Mohamed G. [1 ]
Shi, Wei [1 ]
Feuer, William J. [1 ]
机构
[1] Univ Miami, Miller Sch Med, Bascom Palmer Eye Inst, Miami, FL 33136 USA
[2] Carl Zeiss Meditec Inc, Dublin, CA USA
基金
美国国家卫生研究院;
关键词
COHERENCE TOMOGRAPHY; SPECTRAL-DOMAIN; VARIABILITY; DISC; AGREEMENT;
D O I
10.1167/iovs.10-5222
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To assess the reproducibility of peripapillary retinal nerve fiber layer (RNFL) thickness and optic nerve head (ONH) parameters measured with Cirrus HD-OCT in glaucomatous eyes. METHODS. Fifty-five glaucomatous eyes were included in the study. The optic disc cube 200 x 200 protocol was used to obtain three scans during the same visit to evaluate the intravisit reproducibility. One scan on 4 additional days within a 2-month period of the first session was obtained to assess intervisit reproducibility. Intraclass correlation coefficient (ICC), coefficient of variation (CV), and test-retest SD (TRT SD) were calculated for each RNFL and ONH parameter. The formula 1.645 x root 2 x intervisit TRT SD provides an upper tolerance limit to variability beyond which nonphysiologic change should be considered. RESULTS. All ICCs were excellent, ranging from 83.9% to 99.2% for intravisit measurements and from 80.8% to 99.1% for intervisit measurements. Cup/disc area ratio had the lowest CV (1.1%) in either type of measurement, followed by average RNFL thickness (1.9% and 2.7%). Nasal clock hours and quadrants showed the poorest reproducibility as did the clock hour directly temporally. The intervisit tolerance limit for average RNFL thickness was 3.89 mu m. CONCLUSIONS. Intravisit and intervisit measurements of peripapillary RNFL thickness and ONH parameters with Cirrus HD-OCT showed excellent reproducibility, indicating that this instrument may be useful in monitoring glaucoma progression. When comparing two measurements from the same eye on two different visits, a reproducible decrease in average RNFL thickness of approximately 4 mu m or more may be considered a statistically significant change from baseline. (Invest Ophthalmol Vis Sci. 2010;51:5724-5730) DOI:10.1167/iovs.10-5222
引用
收藏
页码:5724 / 5730
页数:7
相关论文
共 50 条
  • [21] Correlation and Agreement Between Cirrus HD-OCT "RNFL Thickness Map" and Scan Circle Retinal Nerve Fiber Layer Thickness Measurements
    Taibbi, Giovanni
    Kim, James D.
    Bakir, Belal H.
    Shenoy, Sudhir R.
    Pearce, William A.
    Taroyan, Gregory
    Birdsong, Orry C.
    Loucks, Emma K.
    Vizzeri, Gianmarco
    JOURNAL OF GLAUCOMA, 2016, 25 (02) : 208 - 216
  • [22] e Retinal Nerve Fiber Layer Thickness Measurement Repeatability for Cirrus HD-OCT Retinal Tracking System During Eye Movement
    Hwang, Young Hoon
    Song, Miryoung
    Kim, Dai Woo
    Uhm, Ki Bang
    JOURNAL OF GLAUCOMA, 2016, 25 (03) : E214 - E219
  • [23] Reproducibility of retinal nerve fiber thickness measurements using the stratus OCT in normal and glaucomatous eyes
    Budenz, DL
    Chang, RT
    Huang, XR
    Knighton, RW
    Tielsch, JM
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (07) : 2440 - 2443
  • [24] Cirrus HD-OCT Short-Term Repeatability of Clinical Retinal Nerve Fiber Layer Measurements
    Wong, Elizabeth
    Yoshioka, Nayuta
    Kalloniatis, Michael
    Zangerl, Barbara
    OPTOMETRY AND VISION SCIENCE, 2015, 92 (01) : 83 - 88
  • [25] The investigation of retinal nerve fiber layer thickness in eyes with optic nerve head drusen
    Ocakoglu, O
    NEURO-OPHTHALMOLOGY, 2004, 28 (5-6) : 205 - 214
  • [26] Peripapillary Retinal Nerve Fiber Layer and Optic Nerve Head Characteristics in Eyes With Situs Inversus of the Optic Disc
    Kang, Sunah
    Jin, Sunyoung
    Roh, Kyu Hwa
    Hwang, Young Hoon
    JOURNAL OF GLAUCOMA, 2015, 24 (04) : 306 - 310
  • [27] Analysis of peripapilary retinal nerve fiber layer thickness of healthy Chinese from northwestern Shanghai using Cirrus HD-OCT
    Shen Qu
    Xiao-Ting Sun
    Wei Xu
    Ao Rong
    International Journal of Ophthalmology, 2014, (04) : 654 - 658
  • [28] Analysis of peripapilary retinal nerve fiber layer thickness of healthy Chinese from northwestern Shanghai using Cirrus HD-OCT
    Qu, Shen
    Sun, Xiao-Ting
    Xu, Wei
    Rong, Ao
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2014, 7 (04) : 654 - 658
  • [29] Measurement of peripapillary nerve fiber layer thickness at different distances from the optic nerve head with OCT
    Böhm, AG
    Schmidt, E
    Müller-Holz, M
    Pillunat, LE
    OPHTHALMOLOGE, 2006, 103 (05): : 387 - +
  • [30] Evaluation of the reproducibility of retinal nerve fiber layer thickness and optic nerve head parameters with optical coherence tomography
    Rau, Ricardo
    de Freitas Silva, Andre Luiz
    Alves Salame, Andre Luiz
    Soares Melo Junior, Luiz Alberto
    REVISTA BRASILEIRA DE OFTALMOLOGIA, 2012, 71 (05) : 280 - 284