Reproducibility of Peripapillary Retinal Nerve Fiber Layer Thickness and Optic Nerve Head Parameters Measured with Cirrus HD-OCT in Glaucomatous Eyes

被引:224
|
作者
Mwanza, Jean-Claude [1 ]
Chang, Robert T. [1 ]
Budenz, Donald L. [1 ]
Durbin, Mary K. [2 ]
Gendy, Mohamed G. [1 ]
Shi, Wei [1 ]
Feuer, William J. [1 ]
机构
[1] Univ Miami, Miller Sch Med, Bascom Palmer Eye Inst, Miami, FL 33136 USA
[2] Carl Zeiss Meditec Inc, Dublin, CA USA
基金
美国国家卫生研究院;
关键词
COHERENCE TOMOGRAPHY; SPECTRAL-DOMAIN; VARIABILITY; DISC; AGREEMENT;
D O I
10.1167/iovs.10-5222
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To assess the reproducibility of peripapillary retinal nerve fiber layer (RNFL) thickness and optic nerve head (ONH) parameters measured with Cirrus HD-OCT in glaucomatous eyes. METHODS. Fifty-five glaucomatous eyes were included in the study. The optic disc cube 200 x 200 protocol was used to obtain three scans during the same visit to evaluate the intravisit reproducibility. One scan on 4 additional days within a 2-month period of the first session was obtained to assess intervisit reproducibility. Intraclass correlation coefficient (ICC), coefficient of variation (CV), and test-retest SD (TRT SD) were calculated for each RNFL and ONH parameter. The formula 1.645 x root 2 x intervisit TRT SD provides an upper tolerance limit to variability beyond which nonphysiologic change should be considered. RESULTS. All ICCs were excellent, ranging from 83.9% to 99.2% for intravisit measurements and from 80.8% to 99.1% for intervisit measurements. Cup/disc area ratio had the lowest CV (1.1%) in either type of measurement, followed by average RNFL thickness (1.9% and 2.7%). Nasal clock hours and quadrants showed the poorest reproducibility as did the clock hour directly temporally. The intervisit tolerance limit for average RNFL thickness was 3.89 mu m. CONCLUSIONS. Intravisit and intervisit measurements of peripapillary RNFL thickness and ONH parameters with Cirrus HD-OCT showed excellent reproducibility, indicating that this instrument may be useful in monitoring glaucoma progression. When comparing two measurements from the same eye on two different visits, a reproducible decrease in average RNFL thickness of approximately 4 mu m or more may be considered a statistically significant change from baseline. (Invest Ophthalmol Vis Sci. 2010;51:5724-5730) DOI:10.1167/iovs.10-5222
引用
收藏
页码:5724 / 5730
页数:7
相关论文
共 50 条
  • [31] Correction of the Retinal Angle in SD-OCT of Glaucomatous Eyes Provides Better Reproducibility of Optic Nerve Head Parameters
    Lee, Kyungmoo
    Kwon, Young
    Abramo, Michael
    Garvin, Mona
    Sonka, Milan
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [32] Reproducibility of macular ganglion cell-inner plexiform layer thickness measurement with cirrus HD-OCT in normal, hypertensive and glaucomatous eyes
    Francoz, Marlene
    Fenolland, Jean-Remi
    Giraud, Jean-Marie
    El Chehab, Hussam
    Sendon, Damien
    May, Franck
    Renard, Jean-Paul
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2014, 98 (03) : 322 - 328
  • [33] Effect of Ethnicity, Age, and Axial Length on Optic Nerve Head Parameters Measured by CirrusTM HD-OCT
    Knight, O. J.
    Oakley, J. D.
    Durbin, M.
    Callan, T.
    Budenz, D. L.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [34] Correlation of axial length and peripapillary retinal nerve fiber layer thickness measured by Cirrus HD optical coherence tomography in myopes
    Porwal, Sonika
    Nithyanandam, Suneetha
    Joseph, Mary
    Vasnaik, Andrew K.
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2020, 68 (08) : 1584 - 1586
  • [35] Evaluation of Optic Nerve Head Parameters and Retinal Nerve Fiber Layer Thickness in Axial Myopia Using SD OCT
    AttaAllah H.R.
    Omar I.A.N.
    Abdelhalim A.S.
    Ophthalmology and Therapy, 2017, 6 (2) : 335 - 341
  • [36] The correlation of radial peripapillary capillary density measurements with optic nerve head morphology and retinal nerve fiber layer thickness in healthy eyes
    Ozcan, Yasin
    Ozcaliskan, Sehnaz
    Balci, Sevcan
    Artunay, Ozgur
    PHOTODIAGNOSIS AND PHOTODYNAMIC THERAPY, 2020, 32
  • [37] Automatic Detection of the Optic Nerve Head in Line Scanning Ophthalmoscope Images in CIRRUS™ HD-OCT
    Fard, Ali
    Bagherinia, Homayoun
    Stock, Simon
    Straub, Jochen
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [38] Pitfalls in OCT measurement of peripapillary retinal nerve fiber layer thickness in nonglaucomatous optic neuropathy
    Chauhan, Devinder S.
    JOURNAL OF NEURO-OPHTHALMOLOGY, 2008, 28 (02) : 159 - 160
  • [39] Comparison of Peripapillary Retinal Nerve Fiber Layer Thickness Measured by Cirrus and Stratus Optical Coherence Tomography
    Gil-Arribas, L.
    Ferreras, A.
    Caivo, P.
    Pajarin, B.
    Pablo, L. E.
    Polo, V.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [40] Evaluation of peripapillary choroidal and retinal nerve fiber layer thickness in eyes with tilted optic disc
    Ozcimen, Muammer
    Sakarya, Yasar
    Goktas, Sertan
    Sakarya, Rabia
    Ivacik, Ismail S.
    Yener, Halil I.
    Erdogan, Erkan
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2014, 77 (06) : 368 - 372