Evaluation of gantry speed on image quality and imaging dose for 4D cone-beam CT acquisition

被引:29
|
作者
Santoso, Andrew P. [1 ]
Song, Kwang H. [2 ,3 ]
Qin, Yujiao [3 ]
Gardner, Stephen J. [3 ]
Liu, Chang [3 ]
Chetty, Indrin J. [3 ]
Movsas, Benjamin [3 ]
Ajlouni, Munther [3 ]
Wen, Ning [3 ]
机构
[1] Wayne State Univ, Dept Radiat Oncol, Sch Med, Detroit, MI 48201 USA
[2] Texas Oncol, Ft Worth, TX 76104 USA
[3] Henry Ford Hlth Syst, Dept Radiat Oncol, Detroit, MI 48202 USA
关键词
Cone-beam CT; Image guidance; Dosimetry; Motion management; 4-DIMENSIONAL COMPUTED-TOMOGRAPHY; RADIATION-THERAPY; RADIOTHERAPY; PROTOCOL; MOTION; CBCT;
D O I
10.1186/s13014-016-0677-8
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: This study investigates the effect of gantry speed on 4DCBCT image quality and dose for the Varian On-Board Imager (R). Methods: A thoracic 4DCBCT protocol was designed using a 125 kVp spectrum. Image quality parameters were evaluated for 4DCBCT acquisition using Catphan (R) phantom with real-time position management (TM) system for gantry speeds varying between 1.0 to 6.0 degrees/s. Superior-inferior motion of the phantom was executed using a sinusoidal waveform with five second period. Scans were retrospectively sorted into 4 phases (CBCT-4 ph) and 10 phases (CBCT-10 ph); average 4DCBCT (CBCT-ave), using all image data from the 4DCBCT acquisitions was also evaluated. The 4DCBCT images were evaluated using the following image quality metrics: spatial resolution, contrast-to-noise ratio (CNR), and uniformity index (UI). Additionally, Hounsfield unit (HU) sensitivity compared to a baseline CBCT and percent differences and RMS errors (RMSE) of excursion were also determined. Imaging dose was evaluated using an IBA CC13 ion chamber placed within CIRS Thorax phantom using the same sinusoidal motion and image acquisition settings as mentioned above. Results: Spatial resolution decreased linearly from 5.93 to 3.82 lp/cm as gantry speed increased from 1.0 to 6.0 degrees/s. CNR decreased linearly from 4.80 to 1.82 with gantry speed increasing from 1.0 to 6.0 degrees/s, respectively. No noteworthy variations in UI, HU sensitivity, or excursion metrics were observed with changes in gantry speed. Ion chamber dose rates measured ranged from 2.30 (lung) to 5.18 (bone) E-3 cGy/mAs. Conclusions: A quantitative analysis of the Varian OBI's 4DCBCT capabilities was explored. Changing gantry speed changes the number of projections used for reconstruction, affecting both image quality and imaging dose if x-ray tube current is held constant. From the results of this study, a gantry speed between 2 and 3 degrees/s was optimal when considering image quality, dose, and reconstruction time. The future of 4DCBCT clinical utility relies on further investigation of image acquisition and reconstruction optimization.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] 4D cone-beam CT (CBCT) using an on-board imager
    Li, T.
    Xing, L.
    Munro, P.
    Yang, Y.
    Loo, B.
    Koong, A.
    MEDICAL PHYSICS, 2006, 33 (06) : 2234 - 2234
  • [42] A Comparison of 4D Cone-Beam CT Algorithms for Slowly Rotating Scanners
    Bergner, Frank
    Berkus, Timo
    Oelhafen, Markus
    Kunz, Patrik
    Pan, Tinsu
    Kachelriess, Marc
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3764 - +
  • [43] Directional Interpolation for Motion Weighted 4D Cone-Beam CT Reconstruction
    Zhang, Hua
    Sonke, Jan-Jakob
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2012, PT I, 2012, 7510 : 181 - 188
  • [44] Cone-beam CT dose and imaging performance evaluation with a modular, multipurpose phantom
    Siewerdsen, J. H.
    Uneri, A.
    Hernandez, A. M.
    Burkett, G. W.
    Boone, J. M.
    MEDICAL PHYSICS, 2020, 47 (02) : 467 - 479
  • [45] An investigation of 4D cone-beam CT algorithms for slowly rotating scanners
    Bergner, Frank
    Berkus, Timo
    Oelhafen, Markus
    Kunz, Patrik
    Pan, Tinsu
    Grimmer, Rainer
    Ritschl, Ludwig
    Kachelriess, Marc
    MEDICAL PHYSICS, 2010, 37 (09) : 5044 - 5053
  • [46] Fast 4D cone-beam CT from 60 s acquisitions
    Hansen, David C.
    Sorensen, Thomas Sangild
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2018, 5 : 69 - 75
  • [47] Evaluation of image quality for different kV cone-beam CT acquisition and reconstruction methods in the head and neck region
    Elstrom, Ulrik V.
    Muren, Ludvig P.
    Petersen, Jorgen B. B.
    Grau, Cai
    ACTA ONCOLOGICA, 2011, 50 (06) : 908 - 917
  • [48] Image quality of flat panel cone-beam CT
    Rose, G
    Wiegert, J
    Schäfer, D
    Fiedler, K
    Conrads, N
    Timmer, J
    Rasche, V
    Noordhoek, N
    Klotz, E
    Koppe, R
    MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 677 - 683
  • [49] Evaluation of Dose Calculation Based On Cone-Beam CT
    Abe, T.
    Tateoka, K.
    Fujimoto, K.
    Nakazawa, T.
    Saitou, Y.
    Nakata, A.
    Yano, M.
    Sakata, K.
    MEDICAL PHYSICS, 2014, 41 (06) : 259 - 259
  • [50] Evaluation of Clinical Acceptability of DIR Mapped Contours for Adaptive Radiotherapy with 4D Cone-Beam CT
    Balik, S.
    Weiss, E.
    Jan, N.
    Zhang, L.
    Roman, N.
    Sleeman, W.
    Christensen, G.
    Williamson, J.
    Hugo, G.
    MEDICAL PHYSICS, 2013, 40 (06)