Evaluation of gantry speed on image quality and imaging dose for 4D cone-beam CT acquisition

被引:29
|
作者
Santoso, Andrew P. [1 ]
Song, Kwang H. [2 ,3 ]
Qin, Yujiao [3 ]
Gardner, Stephen J. [3 ]
Liu, Chang [3 ]
Chetty, Indrin J. [3 ]
Movsas, Benjamin [3 ]
Ajlouni, Munther [3 ]
Wen, Ning [3 ]
机构
[1] Wayne State Univ, Dept Radiat Oncol, Sch Med, Detroit, MI 48201 USA
[2] Texas Oncol, Ft Worth, TX 76104 USA
[3] Henry Ford Hlth Syst, Dept Radiat Oncol, Detroit, MI 48202 USA
关键词
Cone-beam CT; Image guidance; Dosimetry; Motion management; 4-DIMENSIONAL COMPUTED-TOMOGRAPHY; RADIATION-THERAPY; RADIOTHERAPY; PROTOCOL; MOTION; CBCT;
D O I
10.1186/s13014-016-0677-8
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: This study investigates the effect of gantry speed on 4DCBCT image quality and dose for the Varian On-Board Imager (R). Methods: A thoracic 4DCBCT protocol was designed using a 125 kVp spectrum. Image quality parameters were evaluated for 4DCBCT acquisition using Catphan (R) phantom with real-time position management (TM) system for gantry speeds varying between 1.0 to 6.0 degrees/s. Superior-inferior motion of the phantom was executed using a sinusoidal waveform with five second period. Scans were retrospectively sorted into 4 phases (CBCT-4 ph) and 10 phases (CBCT-10 ph); average 4DCBCT (CBCT-ave), using all image data from the 4DCBCT acquisitions was also evaluated. The 4DCBCT images were evaluated using the following image quality metrics: spatial resolution, contrast-to-noise ratio (CNR), and uniformity index (UI). Additionally, Hounsfield unit (HU) sensitivity compared to a baseline CBCT and percent differences and RMS errors (RMSE) of excursion were also determined. Imaging dose was evaluated using an IBA CC13 ion chamber placed within CIRS Thorax phantom using the same sinusoidal motion and image acquisition settings as mentioned above. Results: Spatial resolution decreased linearly from 5.93 to 3.82 lp/cm as gantry speed increased from 1.0 to 6.0 degrees/s. CNR decreased linearly from 4.80 to 1.82 with gantry speed increasing from 1.0 to 6.0 degrees/s, respectively. No noteworthy variations in UI, HU sensitivity, or excursion metrics were observed with changes in gantry speed. Ion chamber dose rates measured ranged from 2.30 (lung) to 5.18 (bone) E-3 cGy/mAs. Conclusions: A quantitative analysis of the Varian OBI's 4DCBCT capabilities was explored. Changing gantry speed changes the number of projections used for reconstruction, affecting both image quality and imaging dose if x-ray tube current is held constant. From the results of this study, a gantry speed between 2 and 3 degrees/s was optimal when considering image quality, dose, and reconstruction time. The future of 4DCBCT clinical utility relies on further investigation of image acquisition and reconstruction optimization.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Technical assessment of a cone-beam CT scanner for otolaryngology imaging: Image quality, dose, and technique protocols
    Xu, J.
    Reh, D. D.
    Carey, J. P.
    Mahesh, M.
    Siewerdsen, J. H.
    MEDICAL PHYSICS, 2012, 39 (08) : 4932 - 4942
  • [32] Dose and image quality for a cone-beam C-arm CT system
    Fahrig, Rebecca
    Dixon, Robert
    Payne, Thomas
    Morin, Richard L.
    Ganguly, Arundhuti
    Strobel, Norbert
    MEDICAL PHYSICS, 2006, 33 (12) : 4541 - 4550
  • [33] 3D and 4D imaging from multi-threaded cone-beam CT scans
    Knaup, Michael
    Kachelriess, Marc
    Kalender, Willi A.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1881 - 1885
  • [34] In-treatment 4D cone-beam CT with image-based respiratory phase recognition
    Kida, Satoshi
    Masutani, Yoshitaka
    Yamashita, Hideomi
    Imae, Toshikazu
    Matsuura, Taeko
    Saotome, Naoya
    Ohtomo, Kuni
    Nakagawa, Keiichi
    Haga, Akihiro
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2012, 5 (02) : 138 - 147
  • [35] In-treatment 4D cone-beam CT with image-based respiratory phase recognition
    Satoshi Kida
    Yoshitaka Masutani
    Hideomi Yamashita
    Toshikazu Imae
    Taeko Matsuura
    Naoya Saotome
    Kuni Ohtomo
    Keiichi Nakagawa
    Akihiro Haga
    Radiological Physics and Technology, 2012, 5 (2) : 138 - 147
  • [36] 4D Cone-Beam CT reconstruction with 60s acquisition and 60s reconstruction
    Hansen, D.
    Sorensen, T.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S177 - S178
  • [37] Respiratory triggered 4D cone-beam computed tomography: A novel method to reduce imaging dose
    Cooper, Benjamin J.
    O'Brien, Ricky T.
    Balik, Salim
    Hugo, Geoffrey D.
    Keall, Paul J.
    MEDICAL PHYSICS, 2013, 40 (04)
  • [38] Dose and Image Quality Evaluation for Partial and Full-Angle Kilovoltage Cone-Beam CT Protocols
    Kim, S.
    Yoo, S.
    Yin, F.
    Samei, E.
    Yoshizumi, T.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [39] Quantitative Analysis of the Influence of KV Beam Characteristics and Image Acquisition Parameters On Image Quality in Cone-Beam CT
    Samant, S.
    Gopal, A.
    MEDICAL PHYSICS, 2009, 36 (06) : 2440 - +
  • [40] Image Quality Optimization and Soft Tissue Visualization in Cone-Beam CT Imaging
    Castonguay-Henri, Aude
    Matenine, Dmitri
    Schmittbuhl, Matthieu
    de Guise, Jacques A.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 1, 2019, 68 (01): : 283 - 288