Biomechanical evaluation of periprosthetic femoral fracture fixation

被引:144
|
作者
Zdero, Rad [1 ]
Walker, Richard
Waddell, James P.
Schemitsch, Emil H.
机构
[1] St Michaels Hosp, Martin Orthopaed Biomech Lab, Toronto, ON L5G 456, Canada
来源
关键词
D O I
10.2106/JBJS.F.01561
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: A variety of methods are available for the fixation of femoral shaft fractures after total hip arthroplasty. However, few studies in the literature have quantified the performance of such repair constructs. The aim of this study was to evaluate biomechanically four different constructs for the fixation of periprosthetic femoral shaft fractures following total hip arthroplasty. Methods: Twenty synthetic femora were tested in axial compression, lateral bending, and torsion to determine initial stiffness, as well as stiffness following fixation of a simulated femoral midshaft fracture with and without a bone gap. Four fracture fixation constructs (five specimens per group) were assessed: construct A was a Synthes locked plate (a twelve-hole broad dynamic compression plate) with locked screws; construct B, a Synthes locked plate (a twelve-hole broad dynamic compression plate) with cables and locked screws; construct C, a Zimmer nonlocking (eight-hole) cable plate with cables and nonlocked screws; and construct D, a Zimmer nonlocking (eight-hole) cable plate with allograft strut, cables, and nonlocked screws. Axial stiffness, lateral bending stiffness, and torsional stiffness were assessed with respect to baseline intact specimen values. Axial load to failure was also measured for the specimens. Results: Construct D demonstrated either equivalent or superior stiffness in all testing modes compared with the other constructs in femora with both a midshaft fracture and a bone gap. A comparison of constructs A, B, and C demonstrated equivalent stiffness in all test modes (with one exception) in femora with a midshaft fracture and a bone gap. Conclusions: A combination of a nonlocking plate with an allograft strut (construct D) resulted in the highest stiffness of the constructs examined for treating a periprosthetic fracture around a stable femoral component of a total hip replacement. Clinical Relevance: A locked plate (constructs A and B) should be used with caution as a stand-alone treatment for the fixation of a periprosthetic femoral shaft fracture following total hip arthroplasty, particularly with good bone stock.
引用
收藏
页码:1068 / 1077
页数:10
相关论文
共 50 条
  • [31] Periprosthetic supracondylar femoral fractures following knee arthroplasty: a biomechanical comparison of four methods of fixation
    Maekinen, Tatu J.
    Dhotar, Herman S.
    Fichman, Simcha G.
    Gunton, Matthew J.
    Woodside, Mitchell
    Safir, Oleg
    Backstein, David
    Willett, Thomas L.
    Kuzyk, Paul R. T.
    INTERNATIONAL ORTHOPAEDICS, 2015, 39 (09) : 1737 - 1742
  • [32] Distal-third clavicle fracture fixation: a biomechanical evaluation of fixation
    Rieser, G. Ryan
    Edwards, Kenny
    Gould, Gregory C.
    Markert, Ronald J.
    Goswami, Tarun
    Rubino, L. Joseph
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2013, 22 (06) : 848 - 855
  • [33] A BIOMECHANICAL VALIDATION OF A NEW FEMORAL NECK FIXATION DYNAMIC HIP SCREW FOR PROXIMAL FEMORAL FRACTURE
    Lin, Shih-Wei
    Wang, Jaw-Lin
    BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2010, 22 (01): : 53 - 59
  • [34] BIOMECHANICAL EVALUATION OF MEANS OF FIXATION OF THE FRACTURE OF THE NECK OF THE FEMUR
    BURNY, F
    ANDRIANNE, Y
    BOURGOIS, R
    DONKERWOLCKE, M
    JOURNAL OF BIOMECHANICS, 1980, 13 (09) : 802 - 802
  • [35] The unstable iliac fracture: a biomechanical evaluation of internal fixation
    Simonian, PT
    Routt, MLC
    Harrington, RM
    Tencer, AF
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1997, 28 (07): : 469 - 475
  • [36] Biomechanical evaluation of current patella fracture fixation techniques
    Carpenter, JE
    Kasman, RA
    Patel, N
    Lee, ML
    Goldstein, SA
    JOURNAL OF ORTHOPAEDIC TRAUMA, 1997, 11 (05) : 351 - 356
  • [37] Biomechanical Evaluation of Anterior Cruciate Ligament Femoral Fixation Techniques
    Kleweno, Conor P.
    Jacir, Alberto M.
    Gardner, Thomas R.
    Ahmad, Christopher S.
    Levine, William N.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2009, 37 (02): : 339 - 345
  • [38] Hybrid external fixation as a new treatment method for periprosthetic femoral fracture - A case report
    Pafilas, D
    Kourtzis, N
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (01): : 188 - 192
  • [39] Biomechanical evaluation of periprosthetic refractures following distal femur locking plate fixation
    Alexander, Jamie
    Morris, Randal P.
    Kaimrajh, David
    Milne, Edward
    Latta, Loren
    Flink, Adam
    Lindsey, Ronald W.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2015, 46 (12): : 2368 - 2373
  • [40] Biomechanical analysis of the computer-assisted internal fixation of a femoral neck fracture
    Lu, Hui
    Shen, Hongquan
    Zhou, Shuqing
    Ni, Weidong
    Jiang, Dianming
    GENES & DISEASES, 2020, 7 (03) : 448 - 455