Low-energy ion measurements by means of CR-39 nuclear track detectors

被引:11
|
作者
Skladnik-Sadowska, E [1 ]
Baranowski, J [1 ]
Sadowski, M [1 ]
机构
[1] Andrzej Soltan Inst Nucl Studies, Dept Plasma Phys & Technol, PL-05400 Otwock, Poland
关键词
nuclear track detectors; track diameters; acceleration system; Thomson spectrometer; ion parabolas; rod plasma injector;
D O I
10.1016/S1350-4487(01)00179-2
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The paper presents an additional acceleration system, used to shift up an ion energy spectrum by 20 keV, and some examples of the ion parabolas registered by means of a Thomson-type spectrometer within the rod plasma injector (RPI-60) facility, designed for plasma physics and application studies. The use of the described acceleration system and CR-39 track detectors has enabled the registration of ions of energy above 20 keV to be performed. It made possible to measure the ion (e.g. deuteron) energy spectrum more exactly in the low-energy range, what is important for the determination of ion emission characteristics. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:337 / 339
页数:3
相关论文
共 50 条
  • [41] A new method to measure track density and to differentiate nuclear tracks in CR-39 detectors
    Palacios, D
    Palacios, F
    Sajó-Bohus, L
    Pálfalvi, J
    RADIATION MEASUREMENTS, 2001, 34 (1-6) : 119 - 122
  • [42] Fast neutrons detection in CR-39 and DAM-ADC nuclear track detectors
    Abdalla, A. M.
    Ashraf, O.
    Rammah, Y. S.
    Ashry, A. H.
    Eisa, M.
    Tsuruta, T.
    RADIATION PHYSICS AND CHEMISTRY, 2015, 108 : 24 - 28
  • [43] Summary of a comprehensive data bank for nuclear track research using CR-39 detectors
    Rana, Mukhtar Ahmed
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 944
  • [44] Calibration of CN and CR-39 track detectors for measurements of fast deuterons and nitrogen ions
    Soltan Inst for Nuclear Studies, Warsaw, Poland
    Radiat Meas, 1-6 (201-206):
  • [45] THE HEAT EFFECT ON CR-39 NUCLEAR TRACK DETECTORS IRRADIATED BY A PULSED IR LASER
    DURRANI, SMA
    ABUJARAD, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1995, 100 (01): : 97 - 102
  • [46] NEUTRON ENERGY RESPONSE AND BACKGROUND OF ELECTROCHEMICALLY ETCHED NUCLEAR TRACK DETECTORS - STUDY OF VARIOUS CR-39 MATERIALS
    LUSZIKBHADRA, M
    ALBERTS, WG
    PIESCH, E
    RADIATION PROTECTION DOSIMETRY, 1990, 32 (02) : 99 - 103
  • [47] THE EFFECT OF POST-EXPOSURE ANNEALING ON THE TRACK REGISTRATION CHARACTERISTICS OF CR-39 NUCLEAR TRACK DETECTORS
    JAMIL, K
    AHMAD, R
    AKBER, RA
    KHAN, HA
    RADIATION EFFECTS LETTERS, 1981, 58 (3-4): : 71 - 75
  • [48] A PROTON SHADOW CAMERA USING CR-39 TRACK DETECTORS
    STONE, GF
    CEGLIO, NM
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1984, 8 (1-4): : 605 - 608
  • [49] α-Spectroscopy on CR-39 track detectors for the dosimetry of radon daughters
    Mozzo, P.
    Trotti, F.
    Temporin, A.
    Lanciai, M.
    Predicatori, F.
    Righetti, F.
    Tacconi, A.
    Environment International, 1997, 22 (SUPPL. 1):
  • [50] Particularization of alpha contamination using CR-39 track detectors
    Zaki, M. F.
    El-Shaer, Y. H.
    PRAMANA-JOURNAL OF PHYSICS, 2007, 69 (04): : 567 - 574