Low-energy ion measurements by means of CR-39 nuclear track detectors

被引:11
|
作者
Skladnik-Sadowska, E [1 ]
Baranowski, J [1 ]
Sadowski, M [1 ]
机构
[1] Andrzej Soltan Inst Nucl Studies, Dept Plasma Phys & Technol, PL-05400 Otwock, Poland
关键词
nuclear track detectors; track diameters; acceleration system; Thomson spectrometer; ion parabolas; rod plasma injector;
D O I
10.1016/S1350-4487(01)00179-2
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The paper presents an additional acceleration system, used to shift up an ion energy spectrum by 20 keV, and some examples of the ion parabolas registered by means of a Thomson-type spectrometer within the rod plasma injector (RPI-60) facility, designed for plasma physics and application studies. The use of the described acceleration system and CR-39 track detectors has enabled the registration of ions of energy above 20 keV to be performed. It made possible to measure the ion (e.g. deuteron) energy spectrum more exactly in the low-energy range, what is important for the determination of ion emission characteristics. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:337 / 339
页数:3
相关论文
共 50 条
  • [31] STATUS OF DEVELOPMENT IN THE FIELD OF CR-39 TRACK DETECTORS
    SOMOGYI, G
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1981, 5 (04): : 346 - 346
  • [32] Recording efficiency of CR-39 track detectors in vacuum
    Bystritskii, VM
    Grebenyuk, VM
    Revenko, AV
    Stetsenko, SG
    Stolupin, VA
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1997, 40 (04) : 447 - 450
  • [33] A NEW NUCLEAR TRACK FILTER OF CR-39
    BERNDT, M
    SIEGMON, G
    BEAUJEAN, R
    ENGE, W
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1984, 8 (1-4): : 589 - 592
  • [34] Application of CR-39 Solid State Nuclear Track Detectors to Laser-Driven Ion Acceleration Experiments
    Kanasaki, Masato
    Yamauchi, Tomoya
    Oda, Keiji
    Fukuda, Yuji
    PROGRESS IN ULTRAFAST INTENSE LASER SCIENCE XV, 2020, 136 : 133 - 147
  • [35] Comparison of responses of CR-39, PM-355, and PM-600 track detectors to low-energy hydrogen, and helium ions
    Andrzej Soltan Inst for Nuclear, Studies, Otwock-Swierk, Poland
    Nucl Instrum Methods Phys Res Sect B, 1-2 (113-118):
  • [36] Comparison of responses of LR-115A, CR-39 and PM-355 track detectors to pulsed low-energy proton streams
    Malinowski, K
    Skladnik-Sadowska, E
    Sadowski, MJ
    RADIATION MEASUREMENTS, 2005, 40 (2-6) : 371 - 374
  • [37] Comparison of responses of CR-39, PM-355, and PM-600 track detectors to low-energy hydrogen, and helium ions
    Szydlowski, A
    Sadowski, M
    Czyzewski, T
    Jaskóla, M
    Korman, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1999, 149 (1-2): : 113 - 118
  • [38] NEUTRON MICRODOSIMETRY UTILIZING CR-39 SOLID-STATE NUCLEAR TRACK DETECTORS
    STAFFORD, PM
    ALMOND, PR
    HORTON, J
    MEDICAL PHYSICS, 1985, 12 (04) : 545 - 545
  • [39] Response of CR-39 nuclear track detectors to protons with non-normal incidence
    Przybocki, R.
    Johnson, M. Gatu
    Sutcliffe, G.
    Lahmann, B.
    Seguin, F. H.
    Frenje, J.
    Adrian, P.
    Johnson, T. M.
    Pearcy, J.
    Kabadi, N. V.
    Birkel, A.
    Petrasso, R. D.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2021, 92 (01):
  • [40] Calibration of CN and CR-39 track detectors for measurements of fast deuterons and nitrogen ions
    Sadowski, M
    Baranowski, J
    Skladnik-Sadowska, E
    Szydlowski, A
    Kelly, H
    Lepone, A
    Marquez, A
    RADIATION MEASUREMENTS, 1997, 28 (1-6) : 201 - 206