Low-energy ion measurements by means of CR-39 nuclear track detectors

被引:11
|
作者
Skladnik-Sadowska, E [1 ]
Baranowski, J [1 ]
Sadowski, M [1 ]
机构
[1] Andrzej Soltan Inst Nucl Studies, Dept Plasma Phys & Technol, PL-05400 Otwock, Poland
关键词
nuclear track detectors; track diameters; acceleration system; Thomson spectrometer; ion parabolas; rod plasma injector;
D O I
10.1016/S1350-4487(01)00179-2
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The paper presents an additional acceleration system, used to shift up an ion energy spectrum by 20 keV, and some examples of the ion parabolas registered by means of a Thomson-type spectrometer within the rod plasma injector (RPI-60) facility, designed for plasma physics and application studies. The use of the described acceleration system and CR-39 track detectors has enabled the registration of ions of energy above 20 keV to be performed. It made possible to measure the ion (e.g. deuteron) energy spectrum more exactly in the low-energy range, what is important for the determination of ion emission characteristics. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:337 / 339
页数:3
相关论文
共 50 条
  • [21] Improvement of response of CR-39 nuclear track detectors in fast neutron dosimetry
    Brede, HJ
    Gisbertz, A
    Köhler, I
    Pitt, E
    Scharmann, A
    RADIATION PROTECTION DOSIMETRY, 1999, 85 (1-4) : 113 - 116
  • [22] On the sensitivity of CN(R) and CR-39 plastic track detectors to ion irradiation
    Farid, SM
    SOUTH AFRICAN JOURNAL OF SCIENCE, 1996, 92 (08) : 399 - 402
  • [24] XE-136 AND AU-197 ION TRACK REGISTRATION RESPONSE IN CR-39 AND CR-39 (DOP) DETECTORS
    KUMAR, A
    PRASAD, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1994, 93 (03): : 277 - 281
  • [25] On the detecting ability of the CR-39 track detectors in vacuum
    OIYaI, Dubna, Russia
    Pribory i Tekhnika Eksperimenta, 1997, (04): : 12 - 15
  • [26] SENSITIVITY STUDY OF CR-39 PLASTIC TRACK DETECTORS
    HE, YD
    PRICE, PB
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1992, 20 (03): : 491 - 494
  • [27] Sensitivity study of CR-39 plastic track detectors
    He, Y.D.
    Price, P.B.
    Nuclear Tracks and Radiation Measurements, 1992, 20 (03): : 491 - 494
  • [28] ON THE ACCURACY OF TRACK DIAMETER MEASUREMENTS IN CR-39
    WUHNSEN, P
    ENGE, W
    BEAUJEAN, R
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1984, 8 (1-4): : 179 - 182
  • [29] CRITICAL ANGLES OF ETCHING OF CR-39 TRACK DETECTORS
    KHAN, HA
    BRANDT, R
    KHAN, NA
    JAMIL, K
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1984, 35 (02): : 111 - &
  • [30] Particularization of contamination using CR-39 track detectors
    Zaki, M. F.
    El-Shaer, Y. H.