Laboratory-size x-ray microscope using Wolter mirror optics and an electron-impact x-ray source

被引:7
|
作者
Ohba, Akira [1 ]
Nakano, Tomoyasu [1 ]
Onoda, Shinobu [1 ]
Mochizuki, Takahiro [1 ]
Nakamoto, Katsuhiro [1 ]
Hotaka, Hisaya [1 ]
机构
[1] Hamamatsu Photon KK, Hamakita Ku, 5000 Hirakuchi, Hamamatsu, Shizuoka 4348601, Japan
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2021年 / 92卷 / 09期
关键词
TRANSMISSION; TOMOGRAPHY; FIELD; WHOLE;
D O I
10.1063/5.0059906
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We developed a laboratory-size three-dimensional water-window x-ray microscope using condenser and objective grazing incidence Wolter type I mirrors, an electron-impact-type x-ray source, and a back-illuminated CCD. The imaging system was improved for practical applications in life science research fields. Using a new objective mirror with reduced figure errors, a resolution limit of 3.1 line pairs/mu m was achieved for two-dimensional transmission images and sub-micrometer-scale three-dimensional structures were resolved. Incorporating a cryogenic stage into the x-ray microscope, we observed biological samples embedded in ice to evaluate the usefulness of observation in the water-window region and multi-energy observation was demonstrated using an x-ray source with multiple x-ray tubes. Published under an exclusive license by AIP Publishing.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] X-RAY OPTICS + X-RAY MICROANALYSIS
    HEINRICH, KF
    AMERICAN SCIENTIST, 1965, 53 (03) : A382 - &
  • [32] X-RAY OPTICS AND X-RAY MICROANALYSIS
    WERNER
    METALL, 1966, 20 (05): : 550 - &
  • [33] X-RAY OPTICS AND X-RAY MICROANALYSIS
    SANDS, DE
    MICROCHEMICAL JOURNAL, 1965, 9 (01) : 100 - &
  • [34] New developments in X-ray optics for macromolecular crystallography using laboratory X-ray sources
    Arndt, UW
    Bloomer, AC
    CURRENT OPINION IN STRUCTURAL BIOLOGY, 1999, 9 (05) : 609 - 614
  • [35] X-RAY OPTICS AND X-RAY ASTRONOMY
    KANTOR, FW
    TRANSACTIONS OF THE NEW YORK ACADEMY OF SCIENCES, 1968, 30 (08): : 1100 - &
  • [36] X-RAY OPTICS AND X-RAY MICROANALYSIS
    AXON, HJ
    JOURNAL OF THE INSTITUTE OF METALS, 1965, 93 : 607 - &
  • [37] X-ray interferometry technique using an X-ray microfocus laboratory source.
    Voevodina, M.
    Lyatun, S.
    Barannikov, A.
    Lyatun, I
    Snigireva, I
    Snigirev, A.
    ADVANCES IN METROLOGY FOR X-RAY AND EUV OPTICS IX, 2020, 11492
  • [38] Innovative X-ray optics for laboratory
    Pina, L
    Inneman, A
    Hudec, R
    Ticha, H
    Arndt, UW
    Loxley, N
    Fraser, G
    Taylor, M
    Wall, J
    ADVANCES IN LABORATORY-BASED X-RAY SOURCES AND OPTICS III, 2002, 4781 : 119 - 130
  • [39] Evaluation of Laser-Electron X-ray Source and Related Optics for X-ray Diffractometry and Topography
    Polyakov, S. N.
    Artyukov, I. A.
    Blank, V. D.
    Zholudev, S. I.
    Feshchenko, R. M.
    Popov, N. L.
    Yaroslavtsev, A. A.
    Vinogradov, A. V.
    X-RAY LASERS AND COHERENT X-RAY SOURCES: DEVELOPMENT AND APPLICATIONS, 2017, 10243
  • [40] MINIATURE X-RAY POINT SOURCE FOR ALIGNMENT AND CALIBRATION OF X-RAY OPTICS
    PRICE, RH
    BOYLE, MJ
    GLAROS, SS
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1977, 22 (09): : 1196 - 1196