Laboratory-size x-ray microscope using Wolter mirror optics and an electron-impact x-ray source

被引:7
|
作者
Ohba, Akira [1 ]
Nakano, Tomoyasu [1 ]
Onoda, Shinobu [1 ]
Mochizuki, Takahiro [1 ]
Nakamoto, Katsuhiro [1 ]
Hotaka, Hisaya [1 ]
机构
[1] Hamamatsu Photon KK, Hamakita Ku, 5000 Hirakuchi, Hamamatsu, Shizuoka 4348601, Japan
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2021年 / 92卷 / 09期
关键词
TRANSMISSION; TOMOGRAPHY; FIELD; WHOLE;
D O I
10.1063/5.0059906
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We developed a laboratory-size three-dimensional water-window x-ray microscope using condenser and objective grazing incidence Wolter type I mirrors, an electron-impact-type x-ray source, and a back-illuminated CCD. The imaging system was improved for practical applications in life science research fields. Using a new objective mirror with reduced figure errors, a resolution limit of 3.1 line pairs/mu m was achieved for two-dimensional transmission images and sub-micrometer-scale three-dimensional structures were resolved. Incorporating a cryogenic stage into the x-ray microscope, we observed biological samples embedded in ice to evaluate the usefulness of observation in the water-window region and multi-energy observation was demonstrated using an x-ray source with multiple x-ray tubes. Published under an exclusive license by AIP Publishing.
引用
收藏
页数:8
相关论文
共 50 条
  • [11] Testing of X-ray Optics for Synchrotron Studies using a Laboratory Microfocus X-ray Source
    Barannikov, A. A.
    Zverev, D. A.
    Lyatun, I. I.
    Panormov, I. B.
    Rudenko, K. V.
    Snigirev, A. A.
    JOURNAL OF SURFACE INVESTIGATION, 2024, 18 (SUPPL1): : S24 - S33
  • [12] Optimization of a Wolter type I mirror for a soft X-ray microscope
    Chon, KS
    Namba, Y
    Yoon, KH
    PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2006, 30 (02): : 223 - 230
  • [13] AN X-RAY MICROSCOPE WITH A PLASMA X-RAY SOURCE
    NIEMANN, B
    RUDOLPH, D
    SCHMAHL, G
    DIEHL, M
    THIEME, J
    MEYERILSE, W
    NEFF, W
    HOLZ, R
    LEBERT, R
    RICHTER, F
    HERZIGER, G
    OPTIK, 1990, 84 (01): : 35 - 36
  • [14] Soft X-ray ptychography system using a Wolter mirror for achromatic illumination optics
    Kimura, Takashi
    Takeo, Yoko
    Sakurai, Kai
    Furuya, Noboru
    Egawa, Satoru
    Yamaguchi, Gota
    Matsuzawa, Yusuke
    Kume, Takehiro
    Mimura, Hidekazu
    Shimura, Mari
    Ohashi, Haruhiko
    Matsuda, Iwao
    Harada, Yoshihisa
    OPTICS EXPRESS, 2022, 30 (15): : 26220 - 26228
  • [15] Size optimization for mirror segments for X-ray optics
    Biskach, Michael P.
    McClelland, Ryan S.
    Saha, Timo
    Zhang, William W.
    OPTICS FOR EUV, X-RAY, AND GAMMA-RAY ASTRONOMY V, 2011, 8147
  • [16] Fabrication of an X-Ray Mirror Used in a Soft X-Ray Microscope
    Chon, K. S.
    Namba, Y.
    Yoon, K. H.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 1644 - +
  • [17] Full-field x-ray fluorescence imaging microscope with a Wolter mirror
    Takeuchi, A
    Aoki, S
    Yamamoto, K
    Takano, H
    Watanabe, N
    Ando, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (03): : 1279 - 1285
  • [18] Researches on stability of microfocus electron-impact X-ray source
    Ma, Yu-tian
    Liu Jun-Biao
    Zhao Wei-xia
    Geng, Niu
    Li, Han
    8TH INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGIES: DESIGN, MANUFACTURING, AND TESTING OF MICRO- AND NANO-OPTICAL DEVICES AND SYSTEMS; AND SMART STRUCTURES AND MATERIALS, 2016, 9685
  • [19] Soft x-ray scanning photoelectron microscope using Wolter-type focusing mirror
    Hasegawa, M
    Yoneyama, A
    Ninomiya, K
    JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 1996, 80 : 361 - 364
  • [20] OPTICS OF THE FOCUSING X-RAY MICROSCOPE
    DYSON, J
    PROCEEDINGS OF THE PHYSICAL SOCIETY OF LONDON SECTION B, 1952, 65 (392): : 580 - 589