Clinical Outcome and Paravalvular Leakage of the New Balloon-Expandable Edwards Sapien 3 Valve in Comparison to its Predecessor Model (Edwards Sapien XT) in Patients Undergoing Transfemoral Aortic Valve Replacement

被引:15
|
作者
Bocksch, Wolfgang [1 ]
Grossmann, Benita [1 ]
Geisler, Tobias [1 ]
Steeg, Martin [1 ]
Droppa, Michal [1 ]
Jorbenadze, Rezo [1 ]
Haap, Michael [2 ]
Gawaz, Meinrad [1 ]
Fateh-Moghadam, Suzanne [1 ]
机构
[1] Eberhard Karls Univ Tuebingen, Dept Med Cardiovasc Dis 3, Tubingen, Germany
[2] Eberhard Karls Univ Tuebingen, Dept Med 4, Tubingen, Germany
关键词
aortic stenosis; transfemoral aortic valve replacement; paravalvular leakage; residual aortic regurgitation; balloon-expandable valve; MULTICENTER EVALUATION; PREDICTIVE FACTORS; PROGNOSTIC VALUE; TRANSCATHETER; IMPLANTATION; STENOSIS; RISK; RECOMMENDATIONS; GUIDELINES; IMPACT;
D O I
10.1002/ccd.26562
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: The aim of this study was to compare the 30-day procedural, clinical and echocardiographic outcome of the new balloon-expandable Edwards Sapien 3 (ES3) valve with the Edwards Sapien XT (ESXT). Background: Post-implant paravalvular leaks (PVL) after transfemoral aortic valve replacement (TAVR) resulting in residual aortic regurgitation (AR) are a major limitation for long term outcome. New TAVR-devices have to eliminate this problem. Methods: Transfemoral TAVR was performed in 209 consecutive intermediate-high-risk surgical patients (pts) with symptomatic aortic stenosis (ESXT n = 102, ES3 n = 107). Transthoracic echocardiography (TTE) and 3-dimensional computed tomography were used for valve size selection. Primary endpoint of the study was none/trace AR derived by TTE 30-days after TAVR. Results: All pts underwent successfully TAVR with a combined device success of 100/102 (99%) in ESXT and 107/107 (100%) in ES3 pts. Fluoroscopy time (ESXT 11.8 +/- 0.5 min vs. ES3 10.0 +/- 0.5 min, P = 0.003) and contrast (ESXT 188.9 +/- 5.6 mL vs. ES3 170.4 +/- 4.7 mL, P = 0.04) were significantly lower in ES3 patients. 30-day clinical events did not differ. Transvalvular mean pressure gradients were significantly reduced to 7.4 +/- 0.8 mmHg after ESXT and to 10.1 +/- 0.4 mmHg after ES3 implantation. After 30 days none/trace AR was found in 34.3% (n = 35) of all ESXT pts in contrast to 89.7% (n = 96) of all ES3 patients. Moderate-to-severe AR was found rarely (ESXT 2.9% vs. ES3 0%, P = 0.073). Conclusions: Although there was no significant difference in 30 day mortality, the newer ES3 valve reduced significantly residual paravalvular leakage. (C) 2016 Wiley Periodicals, Inc.
引用
收藏
页码:466 / 475
页数:10
相关论文
共 50 条
  • [41] Outcomes after transcatheter valve-in-valve implantation using a balloon-expandable Edwards Sapien valve in patients with degenerated Freestyle aortic bioprosthesis
    Burgdorf, Christof
    Momchilovska, Andrijana Vukadinovikj
    Remppis, Bjoern Andrew
    ANNALS OF CARDIOTHORACIC SURGERY, 2021, 10 (05) : 667 - 673
  • [42] Comparison of Transapical and Transfemoral Aortic Valve Replacement for High Risk Patients With Severe Aortic Stenosis Using the Edwards Sapien Balloon-Expandable Bioprosthesis: In-Hospital and Medium Term Outcomes
    Osten, Mark D.
    Feindel, Christopher
    Rubin, Barry
    Chamberlain, Kristeen
    Ivanov, Joan
    Meineri, Massimiliano
    Mezody, Melitta
    Horlick, Eric M.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (10) : A26 - A26
  • [43] Prevalence and Significance of Patient Prosthesis Mismatch Following Edwards SAPIEN XT and SAPIEN 3 Transcatheter Aortic Valve Replacement
    Vallabhaneni, Srilakshmi
    Matka, Marsel
    Modi, Vivek
    Carey, Matthew
    Sarnoski, Christopher
    Durkin, Raymond
    Olenchock, Stephen
    Razzaghi, Mehdi
    Shirani, Jamshid
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (09)
  • [44] Transfemoral Aortic Valve Replacement With the Edwards SAPIEN and Edwards SAPIEN XT Prosthesis Using Exclusively Local Anesthesia and Fluoroscopic Guidance Feasibility and 30-Day Outcomes
    Durand, Eric
    Borz, Bogdan
    Godin, Matthieu
    Tron, Christophe
    Litzler, Pierre-Yves
    Bessou, Jean-Paul
    Bejar, Karim
    Fraccaro, Chiara
    Sanchez-Giron, Carlos
    Dacher, Jean-Nicolas
    Bauer, Fabrice
    Cribier, Alain
    Eltchaninoff, Helene
    JACC-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (05) : 461 - 467
  • [45] Transfemoral aortic valve implantation is more successful with the Edwards Sapien 3 compared with the Edwards XT for the treatment of symptomatic severe aortic stenosis
    Gonska, Birgid
    Seeger, Julia
    Junker, Alexander
    Rodewald, Christoph
    Trepte, Ulrike
    Scharnbeck, Dominik
    Rottbauer, Wolfgang
    Woehrle, Jochen
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2018, 111 (8-9) : 470 - 479
  • [46] Successful Balloon-expandable Transcatheter Aortic Valve Prosthesis (Edwards SAPIEN 3) Insertion in Severe Bicuspid Aortic Valve Stenosis with Huge Annulus
    Cho, Sang-Cheol
    Yoon, Yong-Hoon
    Kim, Minsoo
    Park, Hanbit
    Om, Sang Yong
    Park, Sangwoo
    Kim, Tae-Oh
    Lee, Sun Hack
    Kwon, Osung
    Lee, Kyusup
    Kang, Do-Yoon
    Ahn, Jung-Min
    Park, Duk-Woo
    Kang, Soo-Jin
    Lee, Seung-Whan
    Kim, Young-Hak
    Lee, Cheol Whan
    Park, Seong-Wook
    Park, Seung-Jung
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (16) : S292 - S293
  • [47] Transcatheter aortic valve replacement with the balloon-expandable SAPIEN 3 valve: Impact of calcium score on valve performance and clinical outcomes
    Guimaraes, Leonardo
    Ferreira-Neto, Alfredo Nunes
    Urena, Marina
    Nombela-Franco, Luis
    Wintzer-Wehekind, Jerome
    Levesque, Marie-Helene
    Himbert, Dominique
    Fischer, Quentin
    Armijo, German
    Vera, Rafael
    Kalavrouziotis, Dimitri
    Rodes-Cabau, Josep
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2020, 306 : 20 - 24
  • [48] Transcatheter Aortic Valve Implantation With the New Balloon-Expandable Sapien 3 Versus Sapien XT Valve System A Propensity Score-Matched Single-Center Comparison
    Nijhoff, Freek
    Abawi, Masieh
    Agostoni, Pierfrancesco
    Ramjankhan, Faiz Z.
    Doevendans, Pieter A.
    Stella, Pieter R.
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (06)
  • [49] Successful transfemoral Edwards SAPIEN 3 valve in valve implantation in a patient with a degenerated aortic bioprosthesis associated with severe paravalvular aortic regurgitation
    Bijuklic, Klaudija
    Hansen, Lorenz
    Witt, Julian
    Schofer, Joachim
    CLINICAL RESEARCH IN CARDIOLOGY, 2015, 104 (01) : 92 - 93
  • [50] Successful transfemoral Edwards SAPIEN 3 valve in valve implantation in a patient with a degenerated aortic bioprosthesis associated with severe paravalvular aortic regurgitation
    Klaudija Bijuklic
    Lorenz Hansen
    Julian Witt
    Joachim Schofer
    Clinical Research in Cardiology, 2015, 104 : 92 - 93