Clinical Outcome and Paravalvular Leakage of the New Balloon-Expandable Edwards Sapien 3 Valve in Comparison to its Predecessor Model (Edwards Sapien XT) in Patients Undergoing Transfemoral Aortic Valve Replacement

被引:15
|
作者
Bocksch, Wolfgang [1 ]
Grossmann, Benita [1 ]
Geisler, Tobias [1 ]
Steeg, Martin [1 ]
Droppa, Michal [1 ]
Jorbenadze, Rezo [1 ]
Haap, Michael [2 ]
Gawaz, Meinrad [1 ]
Fateh-Moghadam, Suzanne [1 ]
机构
[1] Eberhard Karls Univ Tuebingen, Dept Med Cardiovasc Dis 3, Tubingen, Germany
[2] Eberhard Karls Univ Tuebingen, Dept Med 4, Tubingen, Germany
关键词
aortic stenosis; transfemoral aortic valve replacement; paravalvular leakage; residual aortic regurgitation; balloon-expandable valve; MULTICENTER EVALUATION; PREDICTIVE FACTORS; PROGNOSTIC VALUE; TRANSCATHETER; IMPLANTATION; STENOSIS; RISK; RECOMMENDATIONS; GUIDELINES; IMPACT;
D O I
10.1002/ccd.26562
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: The aim of this study was to compare the 30-day procedural, clinical and echocardiographic outcome of the new balloon-expandable Edwards Sapien 3 (ES3) valve with the Edwards Sapien XT (ESXT). Background: Post-implant paravalvular leaks (PVL) after transfemoral aortic valve replacement (TAVR) resulting in residual aortic regurgitation (AR) are a major limitation for long term outcome. New TAVR-devices have to eliminate this problem. Methods: Transfemoral TAVR was performed in 209 consecutive intermediate-high-risk surgical patients (pts) with symptomatic aortic stenosis (ESXT n = 102, ES3 n = 107). Transthoracic echocardiography (TTE) and 3-dimensional computed tomography were used for valve size selection. Primary endpoint of the study was none/trace AR derived by TTE 30-days after TAVR. Results: All pts underwent successfully TAVR with a combined device success of 100/102 (99%) in ESXT and 107/107 (100%) in ES3 pts. Fluoroscopy time (ESXT 11.8 +/- 0.5 min vs. ES3 10.0 +/- 0.5 min, P = 0.003) and contrast (ESXT 188.9 +/- 5.6 mL vs. ES3 170.4 +/- 4.7 mL, P = 0.04) were significantly lower in ES3 patients. 30-day clinical events did not differ. Transvalvular mean pressure gradients were significantly reduced to 7.4 +/- 0.8 mmHg after ESXT and to 10.1 +/- 0.4 mmHg after ES3 implantation. After 30 days none/trace AR was found in 34.3% (n = 35) of all ESXT pts in contrast to 89.7% (n = 96) of all ES3 patients. Moderate-to-severe AR was found rarely (ESXT 2.9% vs. ES3 0%, P = 0.073). Conclusions: Although there was no significant difference in 30 day mortality, the newer ES3 valve reduced significantly residual paravalvular leakage. (C) 2016 Wiley Periodicals, Inc.
引用
收藏
页码:466 / 475
页数:10
相关论文
共 50 条
  • [21] Comparison of the new balloon-expandable SAPIEN 3 versus the SAPIEN XT. 30-day clinical outcome and echocardiographic data after transfemoral aortic valve implantation
    Fateh-Moghadam, Suzanne
    Voesch, Sabrina
    Geisler, Tobias
    Gawaz, Meinrad
    Bocksch, Wolfgang
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (15) : B263 - B263
  • [22] Comparison of Edwards SAPIEN 3 versus SAPIEN XT in transfemoral transcatheter aortic valve implantation: Difference of valve selection in the real world
    Arai, Takahide
    Lefevre, Thierry
    Hovasse, Thomas
    Morice, Marie-Claude
    Garot, Philippe
    Benamer, Hakim
    Unterseeh, Thierry
    Hayashida, Kentaro
    Watanabe, Yusuke
    Bouvier, Erik
    Cormier, Bertrand
    Chevalier, Bernard
    JOURNAL OF CARDIOLOGY, 2017, 69 (3-4) : 565 - 569
  • [23] Transfemoral aortic valve implantation (TAVI) with the balloon-expandable Edwards Sapien 3 valve compared with the self-expanding Medtronic CoreValve
    Seeger, Julia
    Gonska, Birgid
    Rodewald, Christoph
    Scharnbeck, Dominik
    Marcovic, Sinisa
    Rottbauer, Wolfgang
    Woehrle, Jochen
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (15) : B257 - B258
  • [24] Comparison of Hemodynamic Performance of the Balloon-Expandable SAPIEN 3 Versus SAPIEN XT Transcatheter Valve
    Amat-Santos, Ignacio J.
    Dahou, Abdellaziz
    Webb, John
    Dvir, Danny
    Dumesnil, Jean G.
    Allende, Ricardo
    Ribeiro, Henrique B.
    Urena, Marina
    Paradis, Jean-Michel
    DeLarochelliere, Robert
    Dumont, Eric
    Bergeron, Sebastien
    Thompson, Christopher R.
    Pasian, Sergio
    Bilodeau, Sylvie
    Leipsic, Jonathon
    Larose, Eric
    Pibarot, Philippe
    Rodes-Cabau, Josep
    AMERICAN JOURNAL OF CARDIOLOGY, 2014, 114 (07): : 1075 - 1082
  • [25] Overestimation of Paravalvular Leak With Edwards SAPIEN 3 Transcatheter Aortic Valve Replacement
    Kobayashi, Taisei
    Giri, Jay
    Vallabhajosyula, Prashanth
    Herrmann, Howard C.
    Jagasia, Dinesh H.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (05) : E69 - E71
  • [26] Comparison of the new balloon-expandable Edwards Sapien-3 vs Sapien XT valve. A large-scale single-center experience
    Deimling, Raphael
    Frey, Norbert
    Frank, Derk
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (15) : B282 - B282
  • [27] Transcatheter Aortic Valve Replacement With Balloon-Expandable Valves Comparison of SAPIEN 3 Ultra Versus SAPIEN 3
    Rheude, Tobias
    Pellegrini, Costanza
    Lutz, Jannik
    Alvarez-Covarrubias, Hector A.
    Lahmann, Anna Lena
    Mayr, N. Patrick
    Michel, Jonathan
    Kasel, Markus A.
    Joner, Michael
    Xhepa, Erion
    JACC-CARDIOVASCULAR INTERVENTIONS, 2020, 13 (22) : 2631 - 2638
  • [28] First-in-Man Transfemoral Transcatheter Aortic Valve Replacement With the 29 mm Edwards SAPIEN XT Valve
    Freeman, Melanie
    Rodes-Cabau, Josep
    Urena, Marina
    DeLarochelliere, Robert
    Dumont, Eric
    Masson, Jean-Bernard
    Willson, Alexander B.
    Binder, Ronald K.
    Toggweiler, Stefan
    Leipsic, Jonathon
    Wood, David A.
    Webb, John G.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 82 (04) : 664 - 670
  • [29] Latest Generation of Balloon-Expandable Valve, the Edwards Sapien 3 Valve: Less Paravalvular Regurgitation but Higher Transvalvular Pressure Gradients
    Eghbalzadeh, Kaveh
    Kuhn, Elmar W.
    Sabashnikov, Anton
    Weber, Carolyn
    Rahmanian, Parwis Baradaran
    Siedek, Florian
    Mauri, Victor
    Rudolph, Tanja
    Baldus, Stephan
    Madershahian, Navid
    Wahlers, Thorsten C.
    THORACIC AND CARDIOVASCULAR SURGEON, 2019, 67 (04): : 236 - 242
  • [30] Standardized Methodology for Transfemoral Transcatheter Aortic Valve Replacement With the Edwards Sapien XT Valve Under Fluoroscopy Guidance
    Kasel, Albert M.
    Shivaraju, Anupama
    Schneider, Stephan
    Krapf, Stephan
    Oertel, Frank
    Burgdorf, Christof
    Ott, Ilka
    Sumer, Christian
    Kastrati, Adnan
    von Scheidt, Wolfgang
    Thilo, Christian
    JOURNAL OF INVASIVE CARDIOLOGY, 2014, 26 (09): : 451 - 461