Prevalence and Significance of Patient Prosthesis Mismatch Following Edwards SAPIEN XT and SAPIEN 3 Transcatheter Aortic Valve Replacement

被引:2
|
作者
Vallabhaneni, Srilakshmi [1 ]
Matka, Marsel [1 ]
Modi, Vivek [1 ]
Carey, Matthew [2 ]
Sarnoski, Christopher [3 ]
Durkin, Raymond [3 ]
Olenchock, Stephen [4 ]
Razzaghi, Mehdi [5 ]
Shirani, Jamshid [1 ]
机构
[1] St Lukes Univ Hlth Network, Cardiol, Bethlehem, PA 18015 USA
[2] St Lukes Univ Hlth Network, Internal Med, Bethlehem, PA USA
[3] St Lukes Univ Hlth Network, Intervent Cardiol, Bethlehem, PA USA
[4] St Lukes Univ Hlth Network, Cardiac Surg, Bethlehem, PA USA
[5] Bloomsburg Univ Penn, Stat, Bloomsburg, PA 17815 USA
关键词
aortic stenosis; transcatheter aortic valve replacement; patient prosthesis mismatch; outcomes; edwards sapien valve; HIGH-RISK PATIENTS; CLINICAL IMPACT; STENOSIS; IMPLANTATION; PREDICTORS; SURVIVAL; OUTCOMES; TRIAL;
D O I
10.7759/cureus.18044
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Severe patient prosthesis mismatch (sPPM) after surgical aortic valve replacement is associated with worse outcomes. Limited data exists on the impact of sPPM on outcomes after transcatheter aortic valve replacement (TAVR), especially regarding the newer generation valves. The aim of this study was to evaluate the incidence, determinants, and outcomes of sPPM in patients undergoing TAVR with Edwards SAPIEN XT (ES XT) and Edwards SAPIEN 3 (ES3) valves (Edwards Lifesciences, Irvine, CA, USA). Methods We retrospectively reviewed 366 patients who underwent TAVR with ES XT (n = 114) or ES3 (n = 252) valves between July 2012 and June 2018. sPPM was defined as indexed effective orifice area (iEOA) <0.65 cm(2)/m(2). Kaplan-Meier survival estimates were used to determine outcomes. Results Multivariate linear regression analysis was utilized to determine potential independent effects of PPM on outcomes. sPPM was present in 40 (11%) of the patients [8 (7%) ES XT and 32 (13%) ES3] and was associated with female sex, smaller left ventricular outflow tract (LVOT) diameter and aortic valve annular area, absence of prior coronary artery bypass graft (CABG) surgery, shorter height, higher body mass index, and smaller pre-TAVR valve area (all p < 0.05). Among those with ES3 valves, the incidence of sPPM was inversely proportional to the valve size (50%, 25%, 5% and 3% for 20-, 23-, 26- and 29mm valve sizes, respectively; p < 0.001). At a mean follow-up period of 3.5 +/- 1.5 years, there was no difference in all-cause mortality (22.5% vs. 25.6%, p = 0.89) or a composite endpoint of heart failure, arrhythmias, stroke, and myocardial infarction (30% vs. 34%, p = 0.24) in those with or without sPPM. Conclusion ES3 was associated with a higher incidence of sPPM, particularly with smaller valve sizes. However, the presence of sPPM as defined by iEOA was not an independent predictor of adverse outcomes in patients undergoing TAVR within an intermediate follow-up period.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] PROSTHESIS-PATIENT MISMATCH FOLLOWING EDWARDS SAPIEN 3 TRANSCATHETER AORTIC VALVE REPLACEMENT
    Marah, Naddi
    Agha, Ali
    Monlezun, Dominique J.
    Smalling, Richard
    Balan, Prakash
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (09) : 1176 - 1176
  • [2] Determinants of Prosthesis-Patient Mismatch in Patients Undergoing Edwards Sapien and Sapien 3 Transcatheter Aortic Valve Replacement
    Vallabhaneni, Srilakshmi
    Matka, Marsel
    Thacker, Purujit
    Meera, Srinidhi
    Carey, Matthew
    Sarnoski, Christopher
    Durkin, Raymond
    Durkin, Michael
    Olenchock, Stephen
    Amortegui, Jose
    Fitzpatrick, Raymond J.
    Shirani, Jamshid
    CIRCULATION, 2019, 140
  • [3] Prosthesis-Patient Mismatch after Transcatheter Aortic Valve Implantation Using the Edwards SAPIEN Prosthesis
    Van Linden, Arnaud
    Kempfert, Joerg
    Blumenstein, Johannes
    Rastan, Ardawan
    Holzhey, David
    Lehmann, Sven
    Mohr, Friedrich W.
    Walther, Thomas
    THORACIC AND CARDIOVASCULAR SURGEON, 2013, 61 (05): : 414 - 420
  • [4] IMPACT OF PATIENT PROSTHESIS MISMATCH ON CLINICAL OUTCOMES OF PATIENTS UNDERGOING EDWARDS SAPIEN 3 TRANSCATHETER AORTIC VALVE REPLACEMENT (TAVR)
    Vallabhaneni, Srilakshmi
    Matka, Marsel
    Thacker, Purujit
    Carey, Matthew
    Sarnoski, Christopher
    Durkin, Raymond
    Stoltzfus, Jill
    Shirani, Jamshid
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 75 (11) : 2174 - 2174
  • [5] Ventricular Embolization of Edwards SAPIEN Prosthesis Following Transcatheter Aortic Valve Implantation
    Gul, Mehmet
    Erkanli, Korhan
    Erol, Mustafa Kemal
    Bakir, Ihsan
    JOURNAL OF INVASIVE CARDIOLOGY, 2012, 24 (10): : 537 - 538
  • [6] Transfemoral aortic valve implantation of an Edwards Sapien XT valve in a patient with a mechanical mitral prosthesis
    Fraccaro, Chiara
    Tarantini, Giuseppe
    Napodano, Massimo
    Gasparetto, Valeria
    Iliceto, Sabino
    Gerosa, Gino
    Isabella, Giambattista
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2011, 12 (09) : 669 - 670
  • [7] Feasibility and safety of transfemoral transcatheter aortic valve implantation without general anesthesia and transesophageal echocardiography with the Edwards' Sapien and Edwards' Sapien XT prosthesis
    Durand, E.
    Borz, B.
    Godin, M.
    Tron, C.
    Bejar, K.
    Giron, C. Sanchez
    Cribier, A.
    Eltchaninoff, H.
    EUROPEAN HEART JOURNAL, 2011, 32 : 72 - 73
  • [8] Conduction Abnormalities May Be Transient Following Transcatheter Aortic Valve Replacement with the Edwards-Sapien Prosthesis
    Baltodano, Pablo
    Sager, Solomon I.
    O'Neill, Brian P.
    Shah, Sachil
    Martinez, Claudia A.
    Alfonso, Carlos E.
    Martinez-Clark, Pedro
    Cohen, Mauricio G.
    Heldman, Alan W.
    O'Neill, William W.
    Williams, Donald
    Carrillo, Roger G.
    CIRCULATION, 2012, 126 (21)
  • [9] TRANSCATHETER AORTIC VALVE IMPLANTATION WITH SAPIEN XT OR SAPIEN 3 PROSTHESES IN BICUSPID AORTIC VALVE DISEASE
    Kawamori, Hiroyuki
    Maeno, Yoshio
    Abramowitz, Yigal
    Takahashi, Nobuyuki
    Kazuno, Yoshio
    Kashif, Mohammad
    Chakravarty, Tarun
    Cheng, Wen
    Makkar, Raj
    Jilaihawi, Hasan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (13) : 116 - 116
  • [10] Transcatheter Mitral Valve Replacement with the Edwards SAPIEN 3 Valve
    Kar, Biswajit
    Nascimbene, Angelo
    Gregoric, Igor D.
    Patel, Manish
    Loyalka, Pranav
    TEXAS HEART INSTITUTE JOURNAL, 2017, 44 (04): : 269 - 273