Prevalence and Significance of Patient Prosthesis Mismatch Following Edwards SAPIEN XT and SAPIEN 3 Transcatheter Aortic Valve Replacement

被引:2
|
作者
Vallabhaneni, Srilakshmi [1 ]
Matka, Marsel [1 ]
Modi, Vivek [1 ]
Carey, Matthew [2 ]
Sarnoski, Christopher [3 ]
Durkin, Raymond [3 ]
Olenchock, Stephen [4 ]
Razzaghi, Mehdi [5 ]
Shirani, Jamshid [1 ]
机构
[1] St Lukes Univ Hlth Network, Cardiol, Bethlehem, PA 18015 USA
[2] St Lukes Univ Hlth Network, Internal Med, Bethlehem, PA USA
[3] St Lukes Univ Hlth Network, Intervent Cardiol, Bethlehem, PA USA
[4] St Lukes Univ Hlth Network, Cardiac Surg, Bethlehem, PA USA
[5] Bloomsburg Univ Penn, Stat, Bloomsburg, PA 17815 USA
关键词
aortic stenosis; transcatheter aortic valve replacement; patient prosthesis mismatch; outcomes; edwards sapien valve; HIGH-RISK PATIENTS; CLINICAL IMPACT; STENOSIS; IMPLANTATION; PREDICTORS; SURVIVAL; OUTCOMES; TRIAL;
D O I
10.7759/cureus.18044
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Severe patient prosthesis mismatch (sPPM) after surgical aortic valve replacement is associated with worse outcomes. Limited data exists on the impact of sPPM on outcomes after transcatheter aortic valve replacement (TAVR), especially regarding the newer generation valves. The aim of this study was to evaluate the incidence, determinants, and outcomes of sPPM in patients undergoing TAVR with Edwards SAPIEN XT (ES XT) and Edwards SAPIEN 3 (ES3) valves (Edwards Lifesciences, Irvine, CA, USA). Methods We retrospectively reviewed 366 patients who underwent TAVR with ES XT (n = 114) or ES3 (n = 252) valves between July 2012 and June 2018. sPPM was defined as indexed effective orifice area (iEOA) <0.65 cm(2)/m(2). Kaplan-Meier survival estimates were used to determine outcomes. Results Multivariate linear regression analysis was utilized to determine potential independent effects of PPM on outcomes. sPPM was present in 40 (11%) of the patients [8 (7%) ES XT and 32 (13%) ES3] and was associated with female sex, smaller left ventricular outflow tract (LVOT) diameter and aortic valve annular area, absence of prior coronary artery bypass graft (CABG) surgery, shorter height, higher body mass index, and smaller pre-TAVR valve area (all p < 0.05). Among those with ES3 valves, the incidence of sPPM was inversely proportional to the valve size (50%, 25%, 5% and 3% for 20-, 23-, 26- and 29mm valve sizes, respectively; p < 0.001). At a mean follow-up period of 3.5 +/- 1.5 years, there was no difference in all-cause mortality (22.5% vs. 25.6%, p = 0.89) or a composite endpoint of heart failure, arrhythmias, stroke, and myocardial infarction (30% vs. 34%, p = 0.24) in those with or without sPPM. Conclusion ES3 was associated with a higher incidence of sPPM, particularly with smaller valve sizes. However, the presence of sPPM as defined by iEOA was not an independent predictor of adverse outcomes in patients undergoing TAVR within an intermediate follow-up period.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Electrocardiographic Changes During Time and Pacemaker Requirements After Transcatheter Aortic Valve Replacement With Edwards Sapien 3 Prosthesis
    Dolci, Giulia
    Vollema, E. Mara
    Goedemans, Laurien
    van der Kley, Frank
    de Weger, Arend
    Ajmone Marsan, Nina
    Delgado, Victoria
    Bax, Jeroen J.
    CIRCULATION, 2018, 138
  • [42] Successful Transcatheter Aortic Valve Replacement With SAPIEN 3 Valve in a Patient With Quadricuspid Aortic Stenosis
    Ochiai, Tomoki
    Yamanaka, Futoshi
    Moriyama, Noriaki
    Shishido, Koki
    Saito, Shigeru
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 79 (15) : S401 - S403
  • [43] Transaortic transcatheter aortic valve implantation using SAPIEN XT or SAPIEN 3 valves in the ROUTE registry
    Romano, Mauro
    Frank, Derk
    Cocchieri, Riccardo
    Jagielak, Dariusz
    Bonaros, Nikolaos
    Aiello, Marco
    Lapeze, Joel
    Laine, Mika
    Chocron, Sidney
    Muir, Douglas
    Eichinger, Walter
    Thielmann, Matthias
    Labrousse, Louis
    Rein, Kjell Arne
    Verhoye, Jean-Philippe
    Gerosa, Gino
    Baumbach, Hardy
    Deutsch, Cornelia
    Bramlage, Peter
    Thoenes, Martin
    Bapat, Vinayak
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2017, 25 (05) : 757 - 764
  • [44] Management of Paravalvular Regurgitation After Edwards SAPIEN Transcatheter Aortic Valve Replacement
    Martinez, Claudia A.
    Singh, Vikas
    O'Neill, Brian P.
    Alfonso, Carlos E.
    Bilsker, Martin S.
    Clark, Pedro Martinez
    Williams, Donald
    Cohen, Mauricio G.
    Heldman, Alan W.
    O'Neill, William W.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 82 (02) : 300 - 311
  • [45] Transcatheter Edwards Sapien XT valve in valve implantation in degenerated aortic bioprostheses via transfemoral access
    Greif, Martin
    Lange, Philipp
    Mair, Helmut
    Becker, Christoph
    Schmitz, Christoph
    Steinbeck, Gerhard
    Kupatt, Christian
    CLINICAL RESEARCH IN CARDIOLOGY, 2012, 101 (12) : 993 - 1001
  • [46] Edwards Sapien XT valve implantation in CoreValve aortic prosthesis to treat severe paravalvular regurgitation
    Wilson, William
    Osten, Mark
    Horlick, Eric
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2014, 174 (03) : E105 - E107
  • [47] Retrograde, transsubclavian implantation of a SAPIEN XT™ aortic valve prosthesis with the Edwards NovaFlex+™ system
    J. Blumenstein
    A. Van Linden
    J. Kempfert
    Woung-Keung Kim
    C. Liebetrau
    C. Hamm
    H. Nef
    T. Walther
    H. Moellmann
    Clinical Research in Cardiology, 2012, 101 : 773 - 775
  • [48] Retrograde, transsubclavian implantation of a SAPIEN XT™ aortic valve prosthesis with the Edwards NovaFlex+™ system
    Blumenstein, J.
    Van Linden, A.
    Kempfert, J.
    Kim, Woung-Keung
    Liebetrau, C.
    Hamm, C.
    Nef, H.
    Walther, T.
    Moellmann, H.
    CLINICAL RESEARCH IN CARDIOLOGY, 2012, 101 (09) : 773 - 775
  • [49] Transcatheter Edwards Sapien XT valve in valve implantation in degenerated aortic bioprostheses via transfemoral access
    Martin Greif
    Philipp Lange
    Helmut Mair
    Christoph Becker
    Christoph Schmitz
    Gerhard Steinbeck
    Christian Kupatt
    Clinical Research in Cardiology, 2012, 101 : 993 - 1001
  • [50] CORYNEBACTERIUM PROSTHETIC AORTIC VALVE ENDOCARDITIS SUCCESSFULLY TREATED WITH EDWARDS SAPIEN 3 TRANSCATHETER VALVE REPLACEMENT
    Naqvi, Syed Yaseen
    Howell, Erik
    Narins, Craig
    Stuver, Thomas
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (11) : 2215 - 2215